Laserfiche WebLink
N ROOF DEMO HVAC PLAN <br />10=1'-0° <br />ROOF HVAC PLAN <br />N 1/8 -1 -0 <br />PACKAGE HEAT PUMP UNIT <br />TAG <br />LOCATION <br />MANUFACTURER <br />gMODEL No. <br />SERVING <br />MIN. <br />OSA <br />CFM <br />DCV <br />OSA <br />CFM <br />SUPPLY <br />FAN <br />DX COOLING <br />HEATItGAUXCOMP'R <br />FILTER <br />MERV <br />EXH. FAN <br />SINGLE <br />POINT POWER <br />RATED EFFICIENCY <br />@ AHRI <br />WEIGHTS <br />(LBS) <br />CFM <br />E.S.P. <br />(in w.c.) <br />FRPM <br />BHP <br />HP <br />REF. <br />TYPE <br />TOTAL <br />MBH <br />SENS. <br />MBH <br />EDB/ <br />EWB <br />LDB/ <br />LWB <br />AMB <br />(°F) <br />TOTAL <br />MBH <br />EDB <br />TY <br />NO.OF <br />CIRCUITS <br />CFM <br />E.S.P. <br />(in w.e.) <br />BHP <br />HP <br />MCA <br />MOP <br />SCCR <br />(KA) <br />VOLTAGE <br />EMERGENCY <br />POWER <br />COOLING <br />HEATING <br />VIB. <br />ISO <br />UNIT <br />CURB <br />ECONO. <br />TOTALNOTES <br />SEER EER IEER <br />HSPF COP <br />R-P.TL'-01 <br />ROOF-x <br />— EX{S7_x_x_x <br />_ <br />_,._ <br />_z_-RTU-02 <br />-ROOF. <br />—.—xfJU67—. <br />_ <br />_ <br />—._ <br />_z_R-RTU-01 <br />ROOF <br />4WCZ6060B3000A <br />EXIST <br />535 <br />- <br />1780 <br />- <br />830 <br />- <br />4 <br />- <br />57 <br />44.5 <br />- <br />- <br />81 <br />53.5 <br />55 <br />1 <br />1 <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />20811 <br />N <br />15 <br />11.5 <br />- <br />8.3 <br />3.5 <br />- <br />495 <br />120 <br />92 <br />707 <br />2-9 <br />R-RTU-02 <br />ROOF <br />TRANEWSC036Hi <br />EXIST <br />360 <br />- <br />1200 <br />05 <br />795 <br />029 <br />075 <br />- <br />39.43 <br />29.42 <br />80/67 <br />58/57 <br />81 <br />35.8 <br />55 <br />1 <br />2 <br />- <br />- <br />- <br />- <br />26 <br />40 <br />- <br />208/3 <br />N <br />14.3 <br />12.1 <br />- <br />- <br />- <br />- <br />507 <br />N/A <br />88 <br />595 <br />2-5, 7, 8 <br />NOTES: <br />1. DEMO EXISTING UNIT. <br />2. REPLACE EXISTING UNIT WITH NEW, LIKE FOR LIKE. <br />3. RE -USE EXISTING ELECTRICAL DISCONNECT. WIRE DISCONNECT TO NEW UNIT BY E.C. <br />4. CONNECT NEW UNIT TO EXISTING THERMOSTAT BY C.C. <br />S. PROVIDE WITH 100%INTEGRATED ECONOMIZER PER 2018 WSEC/SEC 403.5 <br />6. UNIT COOLING CAPACITY IS GREATER THAN 54,000 BTU/H: PROVIDE WITH ECONOMIZER FAULT DETECTION PER 2018 WSEC/SEC C403.5.5 <br />7. FACTORY -PROVIDED LOW -LEAK MOTORIZED DAMPERS ON OSA INTAKE AND RELIEF PER 2018 WSEC/SEC C403.7.8 <br />8. UNIT COOLING CAPACITY IS GREATER THAN 42,000 BTU/H: PROVIDE UNIT WITH 2-SPEED FAN PER 2018 WSEC/SEC C403.8.5.1 <br />9. PROVIDE WITH (N) CURB ADAPTER ATTATCHMENT TO (E) CURB & UNIT ATTATCHMENT TO ADAPTER PER STRUCTURAL PACKAGE <br />I en ineered <br />systems <br />5300 DENVER AVENUE SOUTH <br />SEATTLE, WASHINGTON 98108 <br />(206) 787-8500 <br />THE PLANS AND SPECIFICATIONS HEREIN <br />ARE OWNED BYAND FOR THE SOLE USE OF <br />ACCO ENGINEERED SYSTEMS, INC. (-ACCO-), <br />AND MAYNOT BE REPRODUCED OR USED <br />BY OTHERS FOR ANYPURPOSE UNLESS <br />AUTHORIZED BYACCO IN WRITING. ACCO <br />CANNOTACCEPTANYLIABILITY, WARRANTY, OR <br />OBLIGATION IN THE EVENT OF UNAUTHORIZED USE <br />AREA OF WORK <br />KEY PLAN <br />9RA <br />��11 o¢ewsy�,�"IfP <br />�ONAI. K^ <br />EXPIRES' 11-2&2024 <br />1 <br />09/01/2023 <br />PERMITSET <br />TD <br />No. <br />Date <br />Description <br />By <br />Revisions <br />Project <br />EVERETT MALL <br />UNIT REPLACEMENT <br />1201 SE EVERETT MALL WAY, ST. D <br />EVERETT, WA. 98208 <br />Title <br />ROOF DEMO & HVAC PLANS, <br />& EQUIPMENT SCHEDULES <br />T.DALGLEISH T.TOUTONGHI <br />Designed By Checked By <br />T.DALGLEISH D.RISTOW <br />Drawn By Project Manager <br />70870663 AS SHOWN <br />Job Number Scale <br />M1.R1 <br />