Laserfiche WebLink
Additional Permits Are Required Permit #: M2309-013 <br />For This Project To Include: Site Address 12SE Everett Mall Way <br />Owner: Everett Mall 11 LLC <br />� Plumbing Application Date: 9/6/6/2023 <br />EVERETT MALL <br />Mechanical Sprinkler Description: Two rooftop units replaced <br />Fire Alarm <br />❑X Electrical Review Status: Approved <br />UNIT REPLACEMENT Review Date: 10/11/2023 <br />City of Everett Permit Review <br />EVERETT Status: Reviewed for Permit <br />10/11/2023 2:20:13 PM <br />SYMBOL LEGEND <br />HVAC <br />PIPING <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />(N)® Z(E) <br />NEW (N)3EXISTING (E) RECTANGULAR SUPPLY AIR DUCT RISER <br />® ® <br />PPLYAIRGRILLE <br />PNEUMATIC ZWCV <br />® <br />EX CONNECTOR <br />(N)m m(E) <br />EW(N)B EXISTING (E) RECTANGULAR OUTSIDE AIR DUCT RISER <br />RETURN AIR GRILLE <br />'�Q^II ,�,I <br />-LIT_ <br />PNEUMATIC SW -CV <br />m <br />TWIN RUBBER SPHERICAL CONNECTOR <br />(N)� �(E) <br />NEW(N)&EXISTING B RECTANGULAR RETURN AIR DUCT RISER <br />® ®EXHAUST <br />GRILLE <br />EUMATIC.UTTERFLYZW-CV <br />O00TRIPLE <br />GROOVED COUPLINGS <br />(N)® �(E) <br />ME w IN) &EXISTING(EI RECTANGULAR EXHAUST AIR DUCT RISER <br />O <br />ROUND DIFFUSER <br />�M Iy <br />PNEUMATIC BUTTERFLY 3W-CV(DIVERTING) <br />[ <br />ENDCAP <br />(N) (E) <br />NEW B EXISTING E) ROUND AIR DUCT RISER <br />o <br />LINEAR DIFFUSER <br />t } <br />PNEUMATIC BUTTERFLY iW-CV(MIXING) <br />BLIND FLANGE <br />NEW SINGLE LINE. DOUBLE LINE RECTANGULAR OR ROUND DUCT <br />SIDEWALLGRILLE <br />MOTORIZED --CV <br />D <br />CONCENTRIC REDUCER <br />EX(STING SINGLE LINE S DOUBLE LINE RECTANGULAR OR ROUND DUCT <br />laWALLLOUVER <br />MOTORIZED BW.CV <br />p <br />ECCENTRIC REDUCER <br />x—xSINGLE <br />LINEDUCTWDRXDEMOLISHED 'OPTION) <br />IS'NG DOUBLE LINE Duc,WDHKTD BE DEMOLISHED CX'OPTION) <br />o 0 <br />IRAL SIDEw ALL(WITH EXTRACTORswITHour EXTRwcTOR) <br />MOTORIZED BUTTERFLY zwcv <br />III <br />UNION <br />�X—X—X <br />x — x-1 <br />I I <br />Lx�� <br />EXISTING DUCTWORK TO BE DEMOLISHED (HATCH OPTION) <br />11t Iflflj lL�e\\ <br />FLEXIBLE DUCT <br />'M ' <br />MOTORIZED BUTTERFLY 3W-CV(DIVERTING) <br />n <br />SCHRADERVALVE <br />V�J <br />DUCT WITH WRAP DIMENSIONS SHOWN AGEIO OF DUCT <br />EFAULTWRAPTHICKNESS=I.S, UNLEESOTHERWIEENOTEDONPLAN3 <br />SYMBIOL SHE ET NUMBER NCALL OUT <br />tM It <br />_} <br />MOTORIZED BUTTERFLY BW.cv(MIXING) <br />FLOW ARROW <br />24'x12'(2'L) <br />��-- <br />CT WITH LINING. DIMENSIONS SHOWN ARE I.D. OF DUCT <br />2 ZX12 3 <br />450 <br />GRILLEIDIFFUSER TAG: <br />gCFLLHDIFFUSER TYPE STZ <br />GATE VALVE <br />EBSDRE GAUGE WITH SHUT-OFF VALVE <br />DEFAULT LINING TH—ESS = <br />1 (TYP2) 4 <br />o <br />SINGLE a DOUBLE LINE DUC-0-WITH TRANSITIONAL FITTIND <br />EO <br />UIPMENT LABEL TAG <br />(�BALL <br />VALVE <br />Up <br />TEMPERATURE SENSOR a THERMOWELL <br />®ROrrU�N <br />SQUARRE/E <br />DOUBLE LINE SQUARE TO ROUND TRANSTIONAL FITTING <br />® <br />ILING OR DUCT ACCESS PAN ELBYGENERALCONTGACTOR <br />BALL VALVE WITH MEMORY STOP <br />THERMOMETER <br />rrt <br />(D0 OI"2,11 <br />[[M <br />(D-RADIUSELBOW@ IN' SQUARE ELBOW WITH TURNING VANES <br />�► <br />FLOW ARROW&FLOW ARROW -CURVED <br />� <br />GLOBEVALVE <br />T <br />PETE'S PLUG <br />�I <br />(I)ROUND DUCT TURNING VERTICAL (2) RECT. DUCT TURNING VERTICAL <br />t ) <br />l <br />VISIOMCLouD <br />Ij <br />TTERFLV SALVE <br />FSFLOW <br />SWITCH <br />UME DAMPER <br />LISLE LD,E MArvuAL vowME DAMPER <br />of <br />SATE <br />MTw,cTOR LINE TRAP TO APPROVED RECEPTOR avPwMBw� <br />ECKVALVE <br />f <br />TRIPLE DUTY VALVE <br />MOTORIZED DAMPER (ELECTRIC) <br />❑O <br />OOR SINK WITH TRAP TO APPROVED RECEPTOR BY PLUMBING <br />CONTRACTOR <br />STRAINER <br />LLL1 <br />LIEFVALVE <br />IPH'g IpIE3MOTORIZED <br />DAMPER (PNEUMATIC) <br />GAS STUSUP BY PLUMBING CONTRACTOR <br />STRAINERWITH BLOWDOWN VALVE <br />1��� <br />YT^�YI <br />WAY WP%VALVE <br />k1 <br />FIRE DAMPER (SINGLE LINE AND DOUBLE LINE) <br />COLD WATER STUBUP BY PLUMBING CONTRACTOR�r <br />SKETSTRAINER <br />5-� <br />CUUM BREAKER <br />E <br />❑'j <br />PRE/SM.— DAMPER (sIrvGLE LINE ArvD DOUBLE LINE) <br />) <br />EUECTRICALEQUI ON <br />CATION BY ELECTRICAL CONTRACTORI <br />�--_$iiii7 <br />SUCTION DIFFUSER <br />�TSTEAM <br />TRAP <br />� <br />DSD I1}F=�=,II <br />SMOKE DETECTOR(DUCTTYPE) <br />A. <br />REVISION DELTA <br />AIRVENT MANUAL <br />III���� <br />ANGLE VALVE <br />STATIC PRESSURE SENSOR <br />& <br />POINT OF CONNECTION <br />AIR VENT -AUTO <br />® <br />SIGHT GLASS <br />SD <br />o DETECTOR (AREA TYPE) <br />® <br />GULATOR <br />PRESSURE REDUCING VALVE <br />FILTER DRIER <br />p# <br />ERMO.-WITH ZONE NUMBER <br />PRESSUREBDBTAININDVALVE <br />4-SOLENOIDVALVE <br />CO <br />2sENSOR <br />® <br />TOFLOwcorvTR0_ <br />WITH SENSING BULB <br />NO2 SENSOR <br />CIRCUITSETTER <br />PRESSUREGAUGE-STEAM <br />coDO <br />SENSOR <br />PAUL VALVE WITH HOSE CONNECTION <br />DIFFERENTIALPRESSURE SENSOR <br />OC <br />cuPANCYSENSOR <br />FLOW METER wuNE <br />A sEBIBS <br />®WALLSWITCH <br />FM <br />FLOWMETERTURBINE <br />ABBREVIATIONS <br />AFF <br />ABOVE FINISHED FLOOR <br />(D) <br />DEMO <br />HT <br />HEIGHT <br />OD <br />OUTSIDE DIMENSION <br />TSTAT <br />THERMOSTAT <br />AHJ <br />AUTHORITY HAVING JURISDICTION <br />CIA <br />DIAMETER <br />HHWR <br />HEATING HOT WATER RETURN <br />OPN'G <br />OPENING <br />TU <br />TOP UP <br />AP <br />ACCESS PANEL <br />DSD <br />DUCT SMOKE DETECTOR <br />HHWS <br />HEATING HOT WATER SUPPLY <br />OSA <br />OUTSIDE AIR <br />TYP <br />TYPICAL <br />ASD <br />AREA SMOKE DETECTOR <br />DWG <br />DRAWING <br />HPG <br />HIGH PRESSURE GAS <br />PLBG <br />PLUMBING <br />UBC <br />UNIFORM BUILDING CODE <br />BDD <br />SACKDRAFT DAMPER <br />(E) <br />EXISTING <br />HPS <br />HIGH PRESSURE STEAM <br />POC <br />POINT OF CONNECTION <br />LC <br />UNDERCUT <br />BF <br />BOTTOM FLAT <br />EA <br />EXHAUST AIR <br />HVLS <br />HIGH VELOCITY LOW SPEED FAN <br />RECIP <br />RECIPROCATING <br />UG <br />UNDERGROUND <br />Boo <br />BOTTOM OF DUCT <br />EG <br />EXHAUST AIR GRILLE <br />ID <br />INSIDE DIMENSION <br />(R) <br />RELOCATE <br />UMC <br />UNIFORM MECHANICAL CODE <br />Sol <br />BOTTOM OF INSULATION <br />ELB <br />ELBOW <br />INS <br />INSULATION <br />RA <br />RETURN AIR <br />UNO <br />UNLESS NOTED OTHERWISE <br />BOP <br />BOTTOM OF PIPE <br />ELEC <br />ELECTRICAL <br />INT <br />INTERIOR <br />RED D <br />REQUIRED <br />UTR <br />UP THROUGH ROOF <br />CA <br />COMPRESSED AIR <br />EQ <br />EQUIPMENT <br />(L) <br />LINED <br />REV <br />REVISION <br />V <br />VENT <br />CD <br />CONDENSATE <br />EXH <br />EXHAUST <br />LR <br />LINEAR RETURN <br />RG <br />RETURN OR TRANSFER GRILLE <br />VAV <br />VARIABLE AIR VOLUME <br />CE <br />CEILING EXHAUST <br />EXT <br />EXTERIOR <br />LS <br />LINEAR SUPPLY <br />RG <br />REFRIGERANT GAS <br />VFD <br />VARIABLE SPEED DRIVE <br />CENTR <br />CENTRIFUGAL <br />(F) <br />FUTURE <br />MA <br />MIXED AIR <br />RGHP <br />REFRIGER/WTGAS-HIG�-I PRESSURE <br />VIF <br />VERIFY IN FIELD <br />CFF <br />CAP FOR FUTURE <br />FD <br />FIRE DAMPER <br />MECH <br />MECHANICAL <br />RH <br />REHEAT <br />VOL <br />VOLUME <br />CFM <br />CUBIC FEET PER MINUTE <br />FLEX <br />FLEXIBLE <br />MPG <br />MEDIUM PRESSURE GAS <br />RL <br />REFRIGERANT LIQUID <br />WMS <br />WIRE MESH SCREEN <br />CHWR <br />CHILLED WATER RETURN <br />FLR <br />FLOOR <br />MFR <br />MANUFACTURER <br />RMF <br />RAPID MOUNT FRAME <br />XFER <br />TRANSFER <br />CHWS <br />CHILLED WATER SUPPLY <br />FLU <br />FLUE <br />MD <br />MOTORIZED DAMPER <br />RNA <br />ROUND NECK ADAPTER <br />CL <br />CENTERLINE <br />FIR <br />FLOOR RETURN <br />MTD <br />MOUNTED <br />FIND <br />ROUND <br />CLG <br />CEILING <br />FS <br />FLOOR SUPPLY <br />MTL <br />METAL <br />RR <br />REFRIGERANT RELIEF <br />CMU <br />CONCRETE MASONRY UNIT <br />FSD <br />FIRE SMOKE DAMPER <br />MUA <br />MAKE UP AIR <br />RS <br />REFRIGERANT SUCTION <br />CO <br />COOLING ONLY <br />GA <br />GAUGE <br />MVD <br />MANUAL VOLUME DAMPER <br />SA <br />SUPPLY AIR <br />CA <br />COMBUSTION AIR <br />GALV <br />GALVANIZED <br />NG <br />NATURAL GAS <br />SG <br />SUPPLY GRILLE <br />CONIC <br />CONCRETE <br />GC <br />GENERAL CONTRACTOR <br />(N) <br />NEW <br />SM <br />SHEET METAL <br />COND <br />CONDENSATE <br />GEXH <br />GREASE EXHAUST <br />N/A <br />NOT APPLICABLE <br />SS <br />STAINLESS STEEL <br />CONN <br />CONNECTION <br />GPH <br />GALLONS PER HOUR <br />NC <br />NORMALLY CLOSED <br />STD <br />STANDARD <br />CONT'R <br />CONTRACTOR <br />GPM <br />GALLONS PER MINUTE <br />NIC <br />NOT IN CONTRACT <br />TA <br />TRANSFER AIR <br />CR <br />CEILING RETURN <br />GR <br />GLYCOL RETURN <br />NO <br />NORMALLY OPEN <br />TD <br />TOP DOWN <br />CS <br />CEILING SUPPLY <br />GS <br />GLYCOL SUPPLY <br />NTS <br />NOT TO SCALE <br />TF <br />TOP FLAT <br />CWR <br />CONDENSER WATER RETURN <br />GYP <br />GYPSUM BOARD <br />OBD <br />OPPOSED BLADE DAMPER <br />TOD <br />TOP OF DUCT <br />CWS <br />ICONDENSER WATER SUPPLY <br />IHOA <br />HAND -OFF -AUTO <br />loc <br />I ON CENTER <br />ITOP <br />I TOP OF PIPE <br />DRAWING INDEX <br />DRAWING INDEX KEY: <br />NOT INCLUDED WITH ISSUE <br />NEW OR REVISED <br />O NO CHANGES <br />LL <br />U <br />LL I <br />li <br />LU <br />L <br />� <br />~ <br />w <br />o <br />SNOT <br />DRAWING TITLE <br />MO.00 <br />COVER SHEET <br />MI <br />CONSTRUCTION REQUIREMENTS <br />M0.03 <br />PERMIT REQUIREMENTS <br />M1.01 <br />1 ST FLOOR HVAC PLAN <br />M5.01 <br />MECHANICAL DETAILS <br />SCOPE OF WORK I <br />1. REMOVE & REPLACE (2) PACKAGE HEAT PUMPS. <br />APPLICABLE CODES <br />WASHINGTON MECHANICAL PROJECTS: <br />ALL WORK SHALL BE IN FULL ACCORDANCE WITH APPLICABLE <br />LOCAL, STATE, AND FEDERAL CODES, LAWS AND REGULATIONS. <br />ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH, <br />BUT NOT LIMITED TO: <br />• 2018 INTERNATIONAL BUILDING CODE WITH WA AMENDMENTS <br />• 2020 NATIONAL ELECTRICAL CODE WITH WA AMENDMENTS <br />• 2018 INTERNATIONAL MECHANICAL CODE WITH WA AMENDMENTS <br />• 2018 UNIFORM PLUMBING CODE WITH WA AMENDMENTS <br />• 2018 WASHINGTON STATE ENERGY CODE <br />• 2018 INTERNATIONAL FIRE CODE WITH WA AMENDMENTS <br />ALL WORK SHALL BE IN ACCORDANCE WITH THE FOLLOWING <br />ADDITIONAL GUIDELINES WHERE REQUIRED BY CODE: <br />• SHEET METAL AND AIR CONDITIONING CONTRACTORS <br />NATIONAL ASSOCIATION (SMACNA) <br />• AMERICAN SOCIETY OF HEATING, REFRIGERATION AND <br />AIR-CONDITIONING ENGINEERS (ASHRAE) <br />• AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) <br />• AMER CAN SOCIETY OF CIVIL ENGINEERS (ASCE) <br />• NATIONAL FIRE PROTECTION AGENCY (NFPA) <br />• OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) <br />PROPERTY INFORMATION <br />PARCEL #: 28051800404300 <br />LEGAL DESCRIPTION: SEC 18 TWP 28 RGE 05LOT 3A EVERETT <br />MALL PLAZA - PHASE III BSP REC'D V1 MISC MAPS PG 22- 23 AF <br />NO 8412195037 BEING PTN OF NW114 SE1/4 TGW W 40FT OF TH <br />PTN EVERETT MALL WAY LY ADJ THRTO VAC PER CITYOF EV <br />ORD NO 1290-86 REC AF 8612240099 <br />en inewed <br />systems <br />5300 DENVER AVENUE SOUTH <br />SEATTLE, WASHINGTON 98108 <br />(206)787-8500 <br />THE PLANS AND SPECIFICATIONS HEREIN <br />ARE OWNED BYAND FOR THE SOLE USE OF <br />ACCO ENGINEERED SYSTEMS, INC. (-ACCO-), <br />AND MAYNOT BE REPRODUCED OR USED <br />BY OTHERS FOR ANY PURPOSE UNLESS <br />AUTHORIZED BYACCO IN WRITING. ACCO <br />CANNOTACCEPTANYLIABILITY, WARRANTY, OR <br />OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. <br />AREA OF WORK <br />KEY PLAN <br />9R �sCq� <br />AONAi. K^ <br />EXPIRES: 11-28-2U24 <br />1 <br />09/01/2023 <br />PERMIT SET <br />TD <br />No. <br />Date <br />Description <br />By <br />Revisions <br />Project <br />EVERETT MALL <br />UNIT REPLACEMENT <br />1201 SE EVERETT MALL WAY, ST. D <br />EVERETT, WA. 98208 <br />Title <br />COVER SHEET <br />T.DALGLEISH T.TOLITONGHI <br />Designed By Checked By <br />T.DALGLEISH D.RISTOW <br />Drawn By Project Manager <br />70870663 AS SHOWN <br />Job Number Scale <br />M0.00 <br />