Laserfiche WebLink
SAFE OFF & DEMO UNIT. INSPECT ROOF CUR <br />FOR ANY DEFECTS THAT MAY CAUSE WATER RTU <br />LEAK INTO SPACE. REPORT DEFICIENCIES. R-01 <br />TYP.2 X lO) <br />X X <br />LIX <br />I <br />IEBC 706.2 <br />Any existing gravity load -carrying structural element for <br />which an alteration causes an increase in design dead, <br />live, or snow load, including snow drift effects, of more <br />than 5 percent shall be replaced or altered as needed <br />to carry the gravity loads required by the International <br />Building Code for new structures. <br />Contractor to verify in field the existing unit's weight is <br />more than the new unit's weight. <br />F— X —1 (D) <br />X X <br />EI x, I <br />X `* X <br />LX I <br />N ROOF DEMO HVAC PLAN <br />10=1'-0° <br />ROOF HVAC PLAN <br />N 1/8._1-0.. <br />PACKAGE HEAT PUMP UNIT <br />TAG <br />LOCATION <br />MANUFACTURER <br />&MODEL No. <br />SERVING <br />MIN. <br />OSA <br />CFM <br />DCV <br />OSA <br />CFM <br />SUPPLY <br />FAN <br />DX COOLING <br />HEATING <br />AUX <br />HEAT <br />KW <br />COMPR <br />FILTER <br />MERV <br />EXH. FAN <br />SINGLE <br />POINT POWERI <br />ED EFFICIENCY <br />@ AHRI <br />WEIGHTS <br />(LBS) <br />NOTES <br />CFM <br />E.S.P. <br />(in w.c.) <br />FRPM <br />BHP <br />HP <br />REF. <br />TYPE <br />TOTAL <br />MBH <br />SENS. <br />MBH <br />EDB/ <br />EWB <br />LDB/ <br />LWB <br />AMB <br />(°F) <br />TOTAL <br />MBH <br />EDB <br />LOB <br />AMB <br />(°F) <br />CITY <br />NO OF <br />CIRCUITS <br />CFM <br />E.S.P. <br />(in w.e.) <br />BHP <br />HP <br />MCA <br />MOP <br />SCCR <br />(KA) <br />VOLTAGE <br />EMERGEOOLING <br />POW <br />HEATING <br />IS. <br />ISO <br />UNIT <br />CURB <br />ECONO. <br />TOTAL <br />EER IEER <br />HSPF COP <br />R-P.TU 01 <br />ROOF— <br />—x—x-EX4ST—x—x—x <br />—;:_ <br />— <br />_ <br />__ <br />—•— <br />— <br />— <br />— <br />— — <br />—,— <br />—„.— <br />_ <br />— <br />—„— <br />— <br />— <br />— <br />— <br />--,— <br />—x— <br />— <br />—x— <br />— <br />— <br />— <br />— <br />—x—x_ <br />—x—x-RTU-02 <br />-ROOF% <br />—.--EJUST—'—`—'—"—————`——————°--'—————"——————`°--'———•——————'—°——"—° <br />— <br />— <br />— <br />—— <br />— <br />--- <br />— <br />_.._._._ _.._._._ <br />R-RTU-01 <br />ROOF <br />4WCZr06OB3000A <br />EXIST <br />535 <br />- <br />1780 <br />- <br />830 <br />- <br />4 <br />- <br />57 <br />44.5 <br />- <br />- <br />81 <br />53.5 <br />55 <br />83 <br />21 <br />- <br />1 <br />1 <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />20811 <br />N11.5 <br />- <br />8.3 <br />3.5 <br />- <br />495 <br />120 <br />92 <br />707 <br />2-9R-RTU-02 <br />ROOF <br />TRANEWSC036H3ROA <br />EXIST <br />360 <br />- <br />1200 <br />0.5 <br />795 <br />0.28 <br />0.75 <br />- <br />39.43 <br />29.42 <br />80/67 <br />58/57 <br />81 <br />35.8 <br />55 <br />83 <br />21 <br />6 <br />1 <br />2 <br />- <br />- <br />- <br />- <br />26 <br />40 <br />- <br />208/3 <br />N <br />12.1 <br />- <br />- <br />- <br />- <br />507 <br />N/A <br />88 <br />595 <br />2-5, 7, 8 <br />NOTES: <br />1. DEMO EXISTING UNIT. <br />2. REPLACE EXISTING UNIT WITH NEW, LIKE FOR LIKE. <br />3. RE -USE EXISTING ELECTRICAL DISCONNECT. WIRE DISCONNECT TO NEW UNIT BY E.C. <br />4. CONNECT NEW UNIT TO EXISTING THERMOSTAT BY C.C. <br />S. PROVIDE WITH 100%INTEGRATED ECONOMIZER PER 2018 WSEC/SEC 403.5 <br />6. UNIT COOLING CAPACITY IS GREATER THAN 54,000 BTU/H: PROVIDE WITH ECONOMIZER FAULT DETECTION PER 2018 WSEC/SEC C403.5.5 <br />7. FACTORY -PROVIDED LOW -LEAK MOTORIZED DAMPERS ON OSA INTAKE AND RELIEF PER 2018 WSEC/SEC C403.7.8 <br />8. UNIT COOLING CAPACITY IS GREATER THAN 42,000 BTU/H: PROVIDE UNIT WITH 2-SPEED FAN PER 2018 WSEC/SEC C403.8.5.1 <br />9. PROVIDE WITH (N) CURB ADAPTER ATTATCHMENT TO (E) CURB & UNIT ATTATCHMENT TO ADAPTER PER STRUCTURAL PACKAGE <br />L City of Everett Permit Review <br />EVERETT Status: Reviewed for Permit <br />10/11/2023 2:20:13 PM <br />I en ineered <br />systems <br />5300 DENVER AVENUE SOUTH <br />SEATTLE, WASHINGTON 98108 <br />(206) 787-8500 <br />THE PLANS AND SPECIFICATIONS HEREIN <br />ARE OWNED BYAND FOR THE SOLE USE OF <br />ACCO ENGINEERED SYSTEMS, INC. (-ACCO-), <br />AND MAYNOT BE REPRODUCED OR USED <br />BY OTHERS FOR ANYPURPOSE UNLESS <br />AUTHORIZED BYACCO IN WRITING. ACCO <br />CANNOTACCEPTANYLIABILITY, WARRANTY, OR <br />OBLIGATION IN THE EVENT OF UNAUTHORIZED USE <br />AREA OF WORK <br />KEY PLAN <br />9RA <br />��11 o¢ewsy�,�"IfP <br />107 <br />�ONAI. K^ <br />EXPIRES' 11-2&2024 <br />1 <br />09/01/2023 <br />PERMITSET <br />TD <br />No. <br />Date <br />Description <br />By <br />Revisions <br />Project <br />EVERETT MALL <br />UNIT REPLACEMENT <br />1201 SE EVERETT MALL WAY, ST. D <br />EVERETT, WA. 98208 <br />Title <br />ROOF DEMO & HVAC PLANS, <br />& EQUIPMENT SCHEDULES <br />T.DALGLEISH T.TOUTONGHI <br />Designed By Checked By <br />T.DALGLEISH D.RISTOW <br />Drawn By Project Manager <br />70870663 AS SHOWN <br />Job Number Scale <br />M1.R1 <br />