Laserfiche WebLink
SOLAR MODULE SPECIFICATIONS TAAE)AIN I a a4k' VlaR'OlTtR'�k(XT' JlaN' <br /> MANUFACTURER/MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) Lum'loo <br /> VMP 37.13 V R BRANCH CIRCUIT #1 OF 10 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.46% SMART ENERGYTODAY <br /> IMP 10.77 A R BRANCH CIRCUIT #2 OF 9 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.38% (SET) <br /> 1550 DIGITAL DR,LEHI,UT <br /> VOC 45.3 V OLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4C 84043,USA <br /> ISC 11.14 A VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> TEMP. COEFF. VOC -0.27%/K = (1.21 AMP X 10) X (0.00129 OHMS/FT) X (73 FT X 2) <br /> PTC RATING 376.55 W <br /> = 12.10 AMPS X 0.00129 OHMS/FT) X 146 FT <br /> MODULE DIMENSION 74"(L)x 41.1"(W) <br /> PANEL WATTAGE 400 W = 2.28 VOLTS SYSTEM INFO <br /> oVRISE = 2.28 VOLTS = 240 VOLTS = 0.95% (19)Q CELLS <br /> INVERTER SPECIFICATIONS E VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4C IS 0.95% Q.PEAKDUOBLKML-G10+ <br /> MANUFACTURER/MODEL ENPHASE IQ8PLUS-72-2 US (240V) (ENPH <br /> OLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE NON FUSED AC DISCONNECT (US-72- -US( <br /> MAX DC SHORT CIRCUIT CURRENT 15 A IQ8PLUS-72-2-US(240V) <br /> CONTINUOUS OUTPUT CURRENT 1.21 A RISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) DC SYSTEM SIZE:7.600kWDC <br /> AC SYSTEM SIZE:5.700 kWAC <br /> AMBIENT TEMPERATURE SPECS = (1.21 AMP X 19) X (0.00051 OHMS/FT) X (5 FT X 2) <br /> RECORD LOW TEMP _5°C = 22.99 AMPS X 0.00051 OHMS/FT) X 10 FT <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C - 0.12 VOLTS REVISIONS <br /> CONDUIT HEIGHT 7/8" oVRISE = 0.12 VOLTS _ 240 VOLTS = 0.05% DESCRIPTION I DATE REV <br /> ROOF TOP TEMP 90°C E VOLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE NON FUSED AC DISCONNECT IS 0.05% REVISION 1 12/06/2022 A <br /> CONDUCTOR TEMPERATURE RATE 48°C OLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP REVISION 01/11/2023 B <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K RISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> PERCENT OF VALUES NUMBER OF CURRENT CARRYING = (1.21 AMP X 19) X (0.00051 OHMS/FT) X (5 FT X 2) PROJECT NAME&ADDRESS <br /> CONDUCTORS IN EMT <br /> 0.80 4-6 - 22.99 AMPS X 0.00051 OHMS/FT) X 10 FT Q <br /> 0.70 7-9 - 0.12 VOLTS U) <br /> 0.50 10-20 oVRISE = 0.12 VOLTS - 240 VOLTS = 0.05% <br /> E VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP IS 0.05% oN <br /> 00 <br /> m <br /> OTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS CD <br /> .46% + 0.95% + 0.05% + 0.05% = 1.51% wI-Zw CD <br /> Z_ UW °° <br /> Q z w It <br /> Lo <br /> CALCULATION C/) w o <br /> W w o <br /> CHANGED Y Q <br /> o z <br /> a- <br /> � Q <br /> Q <br /> m <br /> O <br /> J <br /> DATE: 1/11/2023 <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & NOTES <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-8 <br />