My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1205 SE EVERETT MALL WAY ANY LAB TEST NOW 2023-11-30
>
Address Records
>
SE EVERETT MALL WAY
>
1205
>
ANY LAB TEST NOW
>
1205 SE EVERETT MALL WAY ANY LAB TEST NOW 2023-11-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2023 8:29:24 AM
Creation date
11/2/2023 11:33:34 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1205
Tenant Name
ANY LAB TEST NOW
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TOTAL SUPPORT <br />Innovation • Engineering • BIM • Fabrication <br />A Division of Tomarco Contractor Specialties <br />Basis for Design <br />BUILDING CODE: <br />2018 EDITION OF THE INTERNATIONAL BUILDING CODE SUPPLEMENTED BY THE ASCE 7-16 <br />MATERIAL SPECIFICATIONS: <br />SHEET METAL SCREWS SHALL CONFORM TO ICC REPORT ESR-1976 <br />SEISMIC DESIGN PARAMETERS: <br />DESIGN SPECTRAL ACCELERATION AT SHORT PERIODS SDS=1.083 g <br />SEISMIC DESIGN CATEGORY: D <br />COMPONENT IMPORTANCE FACTOR, IP=1.5 <br />COMPONENT AMPLIFICATION FACTOR, ap=2.5 <br />COMPONENT RESPONSE MODIFICATION FACTOR, Rp=3 <br />WIND DESIGN PARAMETERS: <br />BASIC WIND SPEED (3-SECOND GUST): V it=98 MPH <br />RISK CATEGORY: II <br />EXPOSURE CATEGORY: C <br />SCOPE OF WORK: <br />THE SUPPORTING STRUCTURE IS BEYOND THE SCOPE OF THIS SUBMITTAL. IT IS THE <br />RESPONSIBILITY OF THE CONTRACTOR TO SUBMIT THESE CALCULATIONS AND ASSOCIATED <br />DOCUMENTS TO THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION TO ANALYZE THE <br />ABILITY OF THE SUPPORTING STRUCTURE TO ACCOMMODATE THE REACTIONS FROM THE <br />CONNECTIONS SPECIFIED IN THIS SUBMITTAL. EQUIPMENT DIMENSIONS USED IN <br />CALCULATIONS ARE BASED ON EQUIPMENT DATA SHEETS ATTACHED. CONTRACTOR SHALL <br />FIELD VERIFY DIMENSIONS. EFFECTS FROM THERMAL LOADING IS NOT PART OF THIS <br />ANALYSIS. IF THERMAL LOADING NEEDS TO BE ACCOUNTED FOR ISAT SHALL BE NOTIFIED TO <br />REDESIGN. THIS SET OF CALCULATIONS IS BASED ON THE LOADS AND ASSUMPTIONS STATED <br />WITHIN THIS SUBMITTAL. CONTRACTOR PROCEEDS AT THEIR OWN FABRICATION AND <br />INSTALLATION RISK PRIOR TO FINAL APPROVED SUBMITTAL. IF THE LOADS AND <br />ASSUMPTIONS ARE NOT CORRECT THIS SUBMITTAL SHALL BE REVISED. FOR ANY SPECIAL <br />INSPECTIONS REQUIRED REFER TO ISAT DRAWINGS/DETAILS AND BASIS FOR DESIGN FOR <br />APPLICABLE ESR REPORT(S). <br />Page 3 of 29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.