Laserfiche WebLink
9/8/23, 9:19 AM <br />ATC Hazards by Location <br />A This is a beta release of the new ATC Hazards by Location website. Please contact us with feedback. <br />O The ATC Hazards by Location website <br />will not be updated to support ASCE 7-22. Find out why. <br />ATCHazards <br />by Location <br />Search Information <br />VIEW ( <br />71 <br />\ <br />Address: <br />1205 SE Everett Mall Way, Everett, WA 98208, USA <br />CO Foods <br />Coordinates: <br />47.9136611,-122.2163662 <br />Iholesale w <br />o <br />f <br />Elevation: <br />519 ft <br />t�rl ■ _ <br />�!a <br />Snc <br />Timestamp: <br />2023-09-08T16:19:43.852Z <br />Thornton A. m <br />9a <br />Hazard Type: <br />Seismic <br />SulliVan Park 110thStSE <br />/ Eastmont <br />Reference Document: <br />ASCE7-16 <br />C7OO • �e r`3' <br />r 9 F S I I V F R I A KF <br />Map data ©2023 Google, {ep tia, FT ala error <br />Risk Category: <br />II <br />Site Class: <br />D-default <br />Basic Parameters <br />Name <br />Value <br />Description <br />Ss <br />1.354 <br />MCER ground motion (period=0.2s) <br />S1 <br />0.48 <br />MCER ground motion (period=1.0s) <br />SMS <br />1.625 <br />Site -modified spectral acceleration value <br />SM1 <br />* null <br />Site -modified spectral acceleration value <br />SDg <br />1.083 <br />Numeric seismic design value at 0.2s SA <br />SD1 <br />* null <br />Numeric seismic design value at 1.0s SA <br />* See Section 11.4.8 <br />Additional Information <br />Name <br />Value <br />Description <br />SDC <br />* null <br />Seismic design category <br />Fa <br />1.2 <br />Site amplification factor at 0.2s <br />Fv <br />* null <br />Site amplification factor at 1.0s <br />CRS <br />0.901 <br />Coefficient of risk (0.2s) <br />CR1 <br />0.898 <br />Coefficient of risk (1.0s) <br />PGA <br />0.584 <br />MCEG peak ground acceleration <br />FPGA <br />1.2 <br />Site amplification factor at PGA <br />PGAM <br />0.701 <br />Site modified peak ground acceleration <br />TL <br />6 <br />Long -period transition period (s) <br />SsRT <br />1.354 <br />Probabilistic risk -targeted ground motion (0.2s) <br />SsUH <br />1.503 <br />Factored uniform -hazard spectral acceleration (2 % probability of <br />exceedance in 50 years) <br />SsD <br />3.954 <br />Factored deterministic acceleration value (0.2s) <br />S1 RT <br />0.48 <br />Probabilistic risk -targeted ground motion (1.0s) <br />S1 UH <br />0.534 <br />Factored uniform -hazard spectral acceleration (2 % probability of <br />exceedance in 50 years) <br />S1 D <br />1.629 <br />Factored deterministic acceleration value (1.0s) <br />PGAd <br />1.324 <br />Factored deterministic acceleration value (PGA) <br />* See Section 11.4.8 <br />The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any <br />output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. <br />Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why. <br />Disclaimer <br />https:Hhazards.atcouncil.org/#/seismic?lat=47.9136611&ing=-122.2163662&address=1205 SE Everett Mall Way%2C Everett%2C WA 98208%2C USA 1/2 <br />Page 10 of 29 <br />