A B C D E I F I G I H <br /> MAX AC OPERATING CURRENT CALCS FOR HM-1200 MAX AC OPERATING TOTAL <br /> LOAD CALCS-TOTAL AMPS AVAILABLE #OF MICROINVERTERS MAX OUTPUT CURRENTI I MAX AC OPERATING CURRENT CURRENT FOR HM-1200,600,300 <br /> BUS RATING 120% TOTAL MAIN BREAKERMAX BREAKER SIZE 3 X 5.OA - 15.00A HM-1200 HM-600 HM-300 <br /> 225A X 1.2 = 270 200A = 70A MAX AC OPERATING CURRENT CALCS FOR HM-600 <br /> #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 15.00A + 2.46A + 1.23A = 18.69A <br /> 1 X 2.46A - 2.46A <br /> COMBINER BOX PANEL SIZE CALCS MAX AC OPERATING CURRENT CALCS FOR HM-300 <br /> � NUMBER OF NUMBER OF NOMINAL OUTPUT COMBINED � <br /> CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL 125% TOTAL TOTAL BREAKER SIZE �#OFMICROINVESTERSJ IMAX OUTPUT CURRENTI I MAX AC OPERATING CURRENT <br /> CIRCUIT 1 8 2 X 5.OA B246A <br /> x 1.25 = 12.50A = N/A - 15A 1 X 1.23A = 1.23A <br /> CIRCUIT 2(1 of 3) 1 1 X 1.23A - 1.54A <br /> BREAKER SIZE CALCS <br /> CIRCUIT 2(2 of 3) 2 1 X 2.46A x 1.25 = 3.08A = 10.86A = 15A MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE <br /> CIRCUIT 2(3 of 3) 4 1 5.OA x 1.25 = 6.25A 18.69A x 1.25 x 23.36A = 25A <br /> NOTES: <br /> 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) <br /> 2. 225A LOAD CENTER.(EXISTING) <br /> 3. 30A RATED NON-FUSED LOCKABLE AC DISCONNECT.(NEW) <br /> 4. 125A RATED COMBINER PANEL.(NEW) 1 urlLlry METER(E) <br /> N ALL CONDUIT SIZES ARE MINIMUM SIZES N <br /> ALL WIRE SIZES ARE FOR COPPER WIRE (RAT.UTILITY <br /> RID(E) <br /> (2)8 AWG 7200 EXISTING <br /> (1)8 AWG EGC WIRE AIN SERVICE PANEL(E) <br /> (2)8 AWG 3 <br /> (1)8 AWG EGC <br /> I I MAIE <br /> M ^ / / DISCONNECT(E) CIO SUNTECH STP370S-660/WNHB MODULES Y b d <br /> WITH HOYMILES HM-1200 MICRO <br /> INVERTERS <br /> 4g (2)8 AWG <br /> X81 X41 X31 X21 X11 1)8AWGEGC 25ALOAD-SID <br /> SOLAR OCPD <br /> CIRCUIT#1 (Opposite end of the main disconnect <br /> on the busbar-AfEC705.12(B)(3) <br /> . . . (2)12 AWG <br /> (1)8 AWG EGC <br /> ti ti 4� <br /> 1 SUNTECH STP370S-B601WNHB MODULE 2 SUNTECH STP370S-B60/WNHB MODULES 4 SUNTECH STP370S-B60/WNHB MODULES <br /> WITH HOYMILES HM-300 MICRO WITH HOYMILES HM-600 MICRO WITH HOYMILES HM-1200 MICRO <br /> INVERTER INVERTERS INVERTERS <br /> (1 OF 3) (2 OF 3) (3 OF 3) <br /> X11 (2) X11 X41 (3) X21 X11 <br /> CIRCUIT#2 <br /> (2)12 AWG <br /> (1 <br /> )8 AWG EGC <br /> ti ti ti <br /> LO C)l <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENT/AL-THE INFORMATION CONTAINED EMS NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Katherine Brown DATE: DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> S O L G N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 27/07/2022 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 <br /> P O V V E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 2507 Grand Ave. Everett, WA 98201 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 3 <br /> CONSENT FROM SOLGEN POWER. <br />