Laserfiche WebLink
GENERAL NOTES AERIAL VIEW <br /> CODE AND STANDARDS <br /> ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 INTERNATIONAL BUILDING CODEBLUE RAVEN <br /> (IBC),2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND ALL STATE J r f <br /> A ARMAND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. ++ <br /> 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. a * r <br /> 1403 N. Research Way <br /> SITE NOTES/OSHA REGULATION 't ` • ' •' Orem, UT 84097 <br /> 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 800.377.4480 <br /> 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. • a w WWW.BLUERAVENSOLAR.COM <br /> 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. <br /> 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND r i + y 4 # 1 CONFIDENTIAL-THE INFORMATION <br /> THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECTf # HEREIN CONTAINED SHALL NOT BE <br /> THE BUILDING OR STRUCTURE. { * 1� USED FOR THE BENEFIT OF EXCEPT BLUE RAVEN SOLAR NOR <br /> F <br /> SOLAR CONTRACTOR ! • ' SHALL IT BE DISCLOSED IN WHOLE OR <br /> i • IN PART TO OTHERS OUTSIDE <br /> fJ� i <br /> 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. RECIPIENTS ORGANIZATION,EXCEPT� � � <br /> 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PERt IN CONNECTION WITH THE SALE AND <br /> THE MANUFACTURER'S INSTALLATION REQUIREMENTS. . USE OF THE RESPECTIVE EQUIPMENT, <br /> + <br /> 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF qP 1 _ y WITHOUT THE WRITTEN PERMISSION <br /> STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. •'+�L OF BLUE RAVEN SOLAR LLC. <br /> 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO <br /> LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. <br /> 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A r NABC E P <br /> SUITABLE SEALING COMPOUND. SIP L J ■- fi _ <br /> 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. CERTIFIED] <br /> 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. i -s <br /> 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT fr <br /> PV INSTALLATION <br /> AVAILABLE. <br /> 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC s PROFESSIONAL <br /> PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND Scott Gumey <br /> CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND - A #PV-011719-015866 <br /> LISTED FOR THE APPLICATION PER NEC 690.4(B). <br /> 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. } gr CONTRACTOR: <br /> 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) f' Y • BRS FIELD OPS <br /> IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. } <br /> �.� . <br /> EQUIPMENT LOCATIONS �` r � 800-377-4480 <br /> 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT <br /> WILL BE PROVIDED AS PER SECTION NEC 110.26. 4 It Armor <br /> 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS • ,% - <br /> SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). <br /> 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC <br /> U U <br /> APPLICABLE CODES. # Sealed For A a A z Z Q Q <br /> 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. • Existing Roof & Y► �i !i O <br /> ti +� Attachment Only 1004 W"5E11 O 00 <br /> 00 <br /> PROJECT INFORMATION: . yM W o M <br /> NUMBER OF STORIES: 2 # i Q0) Ijj i1i <br /> CONDUIT RUN: Exterior # r 46056 LL Q Z _E N N <br /> ECOBEE QTY: 0 r .c ?ECS i�p m J � N N <br /> LIGHT BULB QTY: 0ONALW ~ W W <br /> PV METER: Not Required DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX _ < � <br /> ROOF TYPE(1) INFORMATION: O > W N N <br /> WIND SPEED: 110 mph CONSTRUCTION-V-B PV1 - COVER SHEET F_ >- > Lu >- >- <br /> ROOF TYPE: Comp Shingle GROUND SNOW LOAD: 25 Ib/ft2 ZONING: RESIDENTIAL PV2- SITE PLAN 9/8/2023 N 1 W N N <br /> FRAMING TYPE: Manufactured Truss WIND EXPOSURE FACTOR: C PV3- ROOF PLAN — o V U <br /> SHEATHING TYPE: OSB U � (N W Q I0 <br /> ATTACHMENT: SFM Infinity Flashkit SEISMIC DESIGN CATEGORY: D PV4- STRUCTURAL <br /> PV5- ELECTRICAL 3-LINE DIAGRAM <br /> RACKING: Unirac SFM Infinity @ 48" OC Portrait/72" OC Landscape DRAWING BY: <br /> NUMBER OF ATTACHMENTS: 24 SCOPE OF WORK PV6- ELECTRICAL CALCULATIONS <br /> PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore <br /> ROOF TYPE(2) INFORMATION (IF APPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY PV8 -PLACARD <br /> �SEE PV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. (ALL OTHER SHEETS AS REQUIRED) PLOT DATE: <br /> SS- PRODUCT SPEC. SHEETS September 8, 2023 <br /> PROJECTNUMBER: <br /> SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: 845881 <br /> DC SYSTEM SIZE: 5.04 kW DC Snohomish County Public Utilities District <br /> SHEET NAME: <br /> AC SYSTEM SIZE: 3.78 kW AC (PUD) <br /> MODULE TYPE: (12) REC Solar REC420AA PURE-R COVER SHEET <br /> INVERTER TYPE: Enphase IQ7X-96-2-US <br /> MONITORING: Enphase IQ Combiner4 X-IQ-AM1-240-4 PERMIT ISSUER: REVISION: PAGE NUMBER: <br /> City of Everett 0 PV1 <br />