Laserfiche WebLink
STANDARD LABELS ADDITIONAL LABELS <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> WARNINGFOR PV SYSTEM DISCONNECTING MEANS WHERE THE WARN I N G PERMANENT PLAQUE OR DIRECTORY DENOTING THE LABEL U20 <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE PLACARD TO BE LOCATED AT UTILITY METER. <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. MAIN DISTRIBUTION UTILITY DISCONNECT(S) DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> 2017 NEC 690.13(8)] POWER TO THIS BUILDING IS ALSO SUPPLIED SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 <br /> TERMINALS ON THE LINE AND 2020 NEC 690.13(8)] FROM A ROOF MOUNTED SOLAR ARRAY WITH LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> LOAD SIDES MAY BE ENERGIZED A RAPID SHUTDOWN DISCONNECTING MEANS DISCONNECT(S)FOR ALL ELECTRIC POWER 800.377.4480 <br /> WWW.BLUERAVENSOLAR.COM <br /> IN THE OPEN POSITION GROUPED AND LABELED WITHIN LINE OF SITE PRODUCTION SOURCES CAPABLE OF BEING <br /> AND 10 FT OF THIS LOCATION INTERCONNECTED. <br /> CONFIDENTIAL-THE INFORMATION <br /> [2017 NEC 705.10] HEREIN CONTAINED SHALL NOT BE <br /> [2020 NEC 705.10] USED FOR THE BENEFIT OF ANYONE <br /> LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> AAC DISCONNECTA AND WITH THE RATED AC OUTPUT CURRENT AND THE I WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> RATED AC OUTPUT CURRENT 15.72 A [2017 NEC 690.541 POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES USE OF THE RESPECTIVE EQUIPMENT, <br /> 2020 NEC 690.541 WITHOUT THE WRITTEN PERMISSION <br /> SUPPLIED FROM MAIN DISTRIBUTION SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> NOMINAL OPERATING AC VOLTAGE 240 V LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> PRODUCTION SOURCES CAPABLE OF BEING <br /> INTERCONNECTED. NABC E P <br /> IOWARNIN LABELS 2017 NEC 705.10] <br /> IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL [2020 NEC 705.10] CERTIFIED <br /> ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br /> DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL <br /> AND SUBPANELS. PV INSTALLATION <br /> 2017 NEC 705.12(8)(3)] LABEL 10 PROFESSIONAL <br /> SOURCES:UTILITY GRID AND 2020 NEC 705.12(8)(3)] I WARNING PERMANENT PLAQUE DIRECTORY TO BE <br /> PV SOLAR ELECTRIC SYSTEM LOCATED AT MAIN SERVVICE EQUIPMENT DENOTING Scott Gurney <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: <br /> ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN <br /> IO WARN I N LABEL 4 BRS FIELD OPS <br /> APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METER. SERVICE DISCONNECTING MEANS. <br /> TO THE BACK-FED BREAKER FROM THE POWER 2017 NEC 705.10AND 690.56(C)(1)(a)] 800-377-4480 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. [2020 NEC 705.1oAND 690.56(C)] <br /> DO NOT RELOCATE [2017 NEC 705.12(B)(2)(3)(b)] <br /> 2020 NEC 705.12(8)(3)(2)] <br /> THIS OVERCURRENT LABEL 11 <br /> DEVICE ! WARN I N PERMANENT PLAQUE OR DIRECTORY TO BE U U <br /> IL LOCATED AT AC COMBINER PANEL. '' Q 0 <br /> PHOTOVOLTAIC SYSTEM 2017 NEC 110.21(8)] Z o <br /> LABEL 5 [2020 NEC 110.21(8)] O N <br /> OWARNING APPLY TO THE PV COMBINER BOX COMBINER PANEL �VQW W $q 0) 00 ,;j- <br /> [2017 <br /> (2020 NEC 705.12(B)(3)(3)]c)] Q <br /> 4 Q f LLI <br /> DO NOT ADD LOADS F �F <br /> THIS EQUIPMENT FED BY MULTIPLE �Q+ F— > O M lfj <br /> SOURCES.TOTAL RATING OF ALL h �x O Q Q W Lu <br /> OVERCURRENT DEVICES,EXCLUDING PV r LL Q Z N N <br /> MAIN SUPPLY OVERCURRENT SUBPANEL <br /> DEVICE,SHALL NOT EXCEED <br /> UTILITY MAIN IF INTERCONNECTION AC METER PV COMBINER z m J (D N N <br /> AMPACITY OF BUSBAR. METER SERVICE PANEL IS MADE HERE) DISCONNECT (IF APPLICABLE) BOX .e� 54072 �4 < —Illf 3: M M <br /> OA ��'C/S7ER� W Q � W W <br /> O O O O O O O O FSSIONALo = � w NN <br /> SOLAR PV SYSTEM EQUIPPED LABEL 6 O H 0� N ♦yBUILDINGS ♦♦ <br /> PERMANENT WITH <br /> LOCATED AT EACH SERVICE U20 2 3 2 3 7 5 8 J MS SHALL HAVE A C) w U y <br /> WITH RAPID SHUTDOWN O O O O O O O o > <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS U � N LL.I Q Q <br /> TURN RAPID SHUTDOWN ARE CONNECTED ORA D H APPROVED READILY 20213,09, 1"OFI POSTIION TO TCH TO THE VISIBLE LOCATION AND SHALL INDICATE THE LOCATION IF BREAKEROR PLACARDSHUT DOWN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. IS USED DRAWING BY: <br /> AND REDUCE <br /> HOCK HAZARD 2017 NEC 690.56(C)(1)(a)] <br /> SJ <br /> IN THE ARRAY 2020 NEC 690.56(C)] OOR 10Brendan Fillmore <br /> OR PLACARD 1 11 :03 :00 PLOT DATE: <br /> RAPID SHUTDOWN LABEL 7 September 8 2023 <br /> SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br /> SWITCH FOR SWITCH <br /> -06 00 <br /> (2017 NEC 690.56(C)(3)] PROJECT NUMBER: <br /> SOLAR� � 2020 NEC 690.56(C)(2)] <br /> 845881 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 <br /> HANDWRITTEN[NEC 110.21] DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />