Laserfiche WebLink
19011 Wood-Sno Road NE,Suite 100 <br /> Woodinville,WA 98072-4436 <br /> 1111111111111111111111111111111111111111111111111 Phone:425-814-8448 <br /> E NOIr4EERIN C Fax:425-821-2120 <br /> Pacific Ridge Homes Revision Date: 1/11/2021 <br /> Thelon (Elevations A & B) <br /> Vertical Distribution of Lateral Forces <br /> Base Shear. <br /> V= 11.39 kips <br /> Shear Walls: k <br /> Fx = C,� V (Eq. 12.8-11) C,, = 'xhx (Eq. 12.8-12) <br /> 1 Wihk <br /> Diaphragms: <br /> n n F -0.25DSI Wpz [Eq• ]12.10-2 (min) <br /> ( 1 px- a <br /> Fpx= [)Fij)wf }(wpx)...[Eq.12.10-1] <br /> \t=x t=x JJI Fpx=0.4SDSIewpx...[Eq.12.10- 3](max) <br /> Strength Design Seismic Forces(E) <br /> Lateral Portion of Diaphragm <br /> Height, Story Force, Story Shear, Story Weight at/, Force, <br /> Floor Level hx Weight,wx wxhx Fx EFx Moment Fpx <br /> (from base) (ft) (Kips) (ft-Kips) (Kips) (Kips) (ft-Kips) (Kips) (Kips) <br /> Roof 23.3 27.70 644 7.59 7.69 104 28 7.59 <br /> Floor 2 9.5 34.02 323 3.81 11.39 213 62 8.16 <br /> Totals W= 61.72 Kips <br /> Ewxhx= 967 ft-Kips <br /> Strength Design Wind Forces(W) <br /> Lateral Lateral <br /> Force Story Shear Force Story Shear <br /> Floor Level N/S,Hx NIS,FHx LAN,Hx E/W,EH. <br /> (from base) (Kips) (bps) (Kips) (Kips) <br /> Roof 4.67 4.67 7.90 7.90 <br /> Floor 2 4.64 9.31 7.02 14.92 <br /> Diaphragm(ASD) Shear Walls(ASD) <br /> Seismic, Wind N/S Wind OW Seismic, Wind N/S Wind ENV <br /> [0.7E] [0.6W] [0.6W] [0.7E] [0.6W] [0.6W] <br /> (kips) (kips) (kips) (kips) (kips) (kips) <br /> Roof 5.31' 2.80 4.74 Floor 2 5.31 2.80 4.74 <br /> Floor 2 5.72 2.78 4.21 Floor 1 2.67 2.78 4.21 <br /> Garage 0.71 0.76 Garage 0.54_ 0.76 <br /> Date:4/6/2022 <br /> Page: L1.5 <br />