GENERAL NOTES AERIAL VIEW <br /> CODE AND STANDARDS J) ' <br /> 1.ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 INTERNATIONAL BUILDING CODE BLUE RAVEN <br /> (IBC),2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND ALL STATE ;. _ , r. j t <br /> AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. fr 4 <br /> 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. <br /> 1403 N. Research Way <br /> SITE NOTES/OSHA REGULATION + Orem, UT 84097 <br /> 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. ', �+ <br /> „ , �'., � 800.377.4480 <br /> 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. #'t ''y WWW.BLUERAVENSOLAR.COM <br /> 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. <br /> 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND d1 CONFIDENTIAL-THE INFORMATION <br /> THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT •• 4 - • HEREIN CONTAINED SHALL NOT BE <br /> THE BUILDING OR STRUCTURE. •" `, USED FOR THE BENEFIT OF ANYONE <br /> • = • EXCEPT BLUE RAVEN SOLAR NOR <br /> SHALL IT BE DISCLOSED IN WHOLE OR <br /> SOLAR CONTRACTOR „ i IN PART TO OTHERS OUTSIDE <br /> 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. •� RECIPIENTS ORGANIZATION,EXCEPT <br /> 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER • �) , IN CONNECTION WITH THE SALE AND <br /> THE MANUFACTURER'S INSTALLATION REQUIREMENTS. r }n t Ir USE OF THE RESPECTIVE EQUIPMENT, <br /> 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF r WITHOUT THE WRITTEN PERMISSION <br /> STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. OF BLUE RAVEN SOLAR LLC. <br /> 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO •, <br /> LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ' <br /> 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A NABC E P <br /> SUITABLE SEALING <br /> 6..DC WIRING LIMITED COMPOUND. <br /> OPMODULE FOOTPRINT W/ENPHASE AC SYSTEM. "M - ~ ' / <br /> 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. �! �' _ CERTIFIED <br /> 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT PV INSTALLATION <br /> AVAILABLE. •- '. <br /> 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC t PROFESSIONAL <br /> PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND _� ` !11 r Scott Gurney <br /> CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND <br /> too, i #PV-011719-015866 <br /> LISTED FOR THE APPLICATION PER NEC 690.4(B). <br /> 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. _ CONTRACTOR: <br /> 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) BRS FIELD OPS <br /> IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. <br /> 800-377-4480 <br /> EQUIPMENT LOCATIONS <br /> 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT r <br /> WILL BE PROVIDED AS PER SECTION NEC 110.26. <br /> 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS • ,.. <br /> SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). . � � Sealed For <br /> 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC r!' <br /> APPLICABLE CODES. Existing Roof& <br /> Z Q <br /> ��:y' c /� <br /> 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. .y Attachment Only O" �Q�W1�� Q M <br /> N <br /> 0 <br /> PROJECT INFORMATION: ' , Q CNo `{. <br /> ti O) N (+') <br /> NUMBER OF STORIES: 1 1t O W W <br /> i v•/ O <br /> O <br /> L <br /> CONDUIT RUN: Interior ,. „'�� _ 46056 o N N <br /> ECOBEE QTY: 0 <br /> LIGHT BULB QTY: 0 �FSjCISTER�l�@�� <br /> PV METER: Not Required DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX orvALLU o LU LU <br /> ROOF TYPE (1) INFORMATION: O o N >. <br /> m <br /> WIND SPEED: 110 mph CONSTRUCTION -V-B PV1 -COVER SHEET F_ >- >. <br /> Cl) <br /> ROOF TYPE: Comp Shingle GROUND SNOW LOAD: 25 Ib/ft2 ZONING: RESIDENTIAL PV2-SITE PLAN U) >, r— <br /> FRAMING TYPE: Manufactured Truss 10/18/2023 - 04 j U U <br /> WIND EXPOSURE FACTOR: C PV3- ROOF PLAN <br /> SHEATHING TYPE: OSB V l— Lo W Q C3 <br /> ATTACHMENT: SFM Infinity Flashkit SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL <br /> LINE DIAGRAM <br /> PV6- ELECTRICAL C <br /> RACKING: Unirac SFM Infinity @ 48" OC Portrait/72"OC Landscape PV5- ELECTRICAL <br /> CALCULATIONS DRAWING BY: <br /> NUMBER OF ATTACHMENTS: 15 SCOPE OF WORK <br /> PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore <br /> ROOF TYPE (2) INFORMATION (IFAPPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHER SHEETS AS REQUIRED) <br /> *SEE PV4.2 <br /> NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SS- PRODUCT SPEC. SHEETS PLOT DATE: <br /> October 17, 2023 <br /> PROJECT NUMBER: <br /> SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: 875774 <br /> DC SYSTEM SIZE: 3.36 kW DC Snohomish County Public Utilities District <br /> AC SYSTEM SIZE: 2.52 kW AC (PUD) SHEET NAME: <br /> MODULE TYPE: (8) REC Solar REC420AA PURE-R COVER SHEET <br /> INVERTER TYPE: Enphase IQ7X-96-2-US <br /> MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 PERMIT ISSUER: REVISION: PAGE NUMBER: <br /> City of Everett 0 PV 1 <br />