My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5527 BROADWAY 2023-11-28
>
Address Records
>
BROADWAY
>
5527
>
5527 BROADWAY 2023-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 10:23:34 AM
Creation date
11/8/2023 6:16:58 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
5527
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STANDARD LABELS ADDITIONAL LABELS <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> FA,WARNING� FOR PV SYSTEM DISCONNECTING MEANS WHERE THE O WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE LABEL U20 <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE PLACARD TO BE LOCATED AT UTILITY METER. <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> (2017 NEC 690.13(8)1 SUPPLIED FROM MAIN DISTRIBUTION SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 <br /> TERMINALS ON THE LINE AND (2020 NEC 690.13(8)1 LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> LOAD SIDES MAY BE ENERGIZED UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER 800.377.4480 <br /> IN THE OPEN POSITION PRODUCTION SOURCES CAPABLE OF BEING WWW.BLUERAVENSOLAR.COM <br /> INTERCONNECTED. CONFIDENTIAL-THE INFORMATION <br /> [2017 NEC 705.10] HEREIN CONTAINED SHALL NOT BE <br /> [2020 NEC 705.10] USED FOR THE BENEFIT OF ANYONE <br /> LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> I ADISCONNECTI AND WITH THE RATED AC OUTPUT CURRENT AND THE 0 WAR N I N G PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> (2017 NEC 690.54] POWER TO THIS BUILDING IS ALSO SUPPLIED DISCONNECTING MEANS ON OR IN THE PREMISES USE OF THE RESPECTIVE EQUIPMENT, <br /> RATED AC OUTPUT CURRENT 10.48 A 12020 NEC 690.54] WITHOUT THE WRITTEN PERMISSION <br /> FROM A ROOF MOUNTED SOLAR ARRAYSOLAR SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> . <br /> NOMINAL OPERATING AC VOLTAGE 240 V LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> ARRAY RAPID SHUTDOWN DISCONNECT IS DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> LOCATED OUTSIDE NEXT TO THE UTILITY METER. PRODUCTION SOURCES CAPABLE OF BEING <br /> INTERCONNECTED. NABCEP <br /> LABEL 3 <br /> 0 WARNING IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL [2017 NEC 705.10] <br /> ANYWHERE THAT IS POWERED BY BOTH THE UTILITY (2020 NEC 705.10] CERTIFIED <br /> DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL <br /> AND SUBPANELS. PV INSTALLATION <br /> (2017 NEC 705.12(8)(3)] LABEL 10 PROFESSIONAL <br /> SOURCES: UTILITY GRID AND (2020 NEC 705.12(8)(3)] ! WARNING PERMANENT PLAQUE DIRECTORY TO BE <br /> PV SOLAR ELECTRIC SYSTEM 7LOCATED AT MAIN SERVVICE EQUIPMENT DENOTING Scott Gurney <br /> PHOTOVOLTAIC SYSTEM THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> COMBINER PANEL SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: <br /> D WARN I N G LABEL 4 GROUPED AND WITHIN LINE OF SITE OF MAIN BRS FIELD OPS <br /> APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT DO NOT ADD LOADS SERVICE DISCONNECTING MEANS. <br /> TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] 800-377-4480 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. [2020 NEC 705.10 AND 690.56(C)] <br /> DO NOT RELOCATE 12017 NEC 705.12(8)(2)(3)(b)] <br /> (2020 NEC 705.12(8)(3)(2)] <br /> THIS OVERCURRENT LABEL 11 <br /> DEVICE PERMANENT PLAQUE OR DIRECTORY TO BE U U <br /> LOCATED AT AC COMBINER PANEL. Z Q <br /> [2017 NEC 110.21(8)] <br /> [2020 NEC 110.21(8)] O M <br /> SOLAR PV SYSTEM EQUIPPED W w Cq � co <br /> WITH RAPID SHUTDOWN t�� <br /> TURN RAPID SHUTDOWN CH TO THE �Q+v��l'' +tI>/��i�r, N > N M <br /> OFF"POSITION TO `, ti ���WAS "Y�(� Lij <br /> �� 0 O O A�' A' <br /> SHUT DOWN PV SYSTEM SUBPANEL PV �� �� 0) N N <br /> SAND REDUCE UTILITY MAIN AC METER PV COMBINER � <br /> SAND REDUCE Z � U) V/ <br /> INTHE ARRAY (IF INTERCONNECTION ..., U <br /> METER SERVICE PANEL IS MADE HERE) DISCONNECT (IF APPLICABLE) BOX LU C <br /> 54072 w� o N N <br /> RAPID SHUTDOWNLABEL 6SWITCH FOR O O O O O O 11 ��� S�GISTER�G ' o m N <br /> BUILDINGS WITH PV SYSTEMS SHALL HAVE A U20 IONALti� U) � <br /> PERMANENT LABEL LOCATED AT EACH SERVICEO O O O = Lo > <br /> O V U <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS V Lo Lij Q Q <br /> ARE CONNECTED OR AT AN APPROVED READILY <br /> VISIBLE LOCATION AND SHALL INDICATE THE LOCATION O IF BREAKER O OR PLACARD <br /> ARNING OF RAPID SHUTDOWN INITIATION DEVICES. IS USED • WING BY: <br /> (2017 NEC 690.56(C)(1)(a)] <br /> 3Lw 2023 . 10 1 DRAMAIN DISTRIBUTION UTILITY DISCONNECT(S) 12020 NEC 690.56(C)] OR 10 Brendan Fillmore <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED OR PLACARD PLOT DATE: <br /> FROM A ROOF MOUNTED SOLAR ARRAY WITH 8 11 :30 -611 October 17A RAPID SHUTDOWN DISCONNECTING MEANS LABEL7 <br /> GROUPED AND LABELED WITHIN LINE OF SITE SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT , 2023 <br /> AND 10 FT OF THIS LOCATION SWITCH <br /> 12017 NEC 690.56(C)(3)] PROJECT NUMBER: <br /> 12020 NEC 690.56(C)(2)] -06'00' <br /> 875774 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 <br /> HANDWRITTEN[NEC 110.211 DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />
The URL can be used to link to this page
Your browser does not support the video tag.