Laserfiche WebLink
S2 Raceway Wired Illuminated Letterset on Backer <br />Remove existing illuminated letterset. Patch & paint facade (SW4064 <br />Pillowcase) to like new condition. Install new letterset as shown. <br />NOTE. No electrical penetrations can be made below the roofline. <br />All penetrations must be through parapet wall. Surface connection <br />from lower raceway to upper raceway will be necessary. <br />CODE NOTE: Wall sign greater of 48 SF or 15% of the area of the <br />building facade up to a maximum of 300 SF. <br />19 x 54 =1026 x 15% =153.9 SF Max <br />CROSS SECTION <br />(nts) <br />1" Black Jewelite trim cap <br />bonded to face <br />3" .040" aluminum <br />letter return, pre -coat black, <br />satin finish <br />3/16" #7328 <br />white acrylic letter face <br />electrical bushing <br />LED module <br />.063" pre -coated white <br />aluminum backs <br />1/4" dia. weep holes <br />with light cover <br />.080" aluminum backer panel <br />painted Matthews N923SP Black, <br />satin finish <br />Pill Lightbox; <br />fabrication identical <br />to letters above <br />3/16" #7328 <br />white acrylic face with <br />first surface black vinyl <br />with copy weeded out <br />3" � � 4.51'-� <br />4.5" x 7" <br />Raceway (add weep holes); <br />typ. paint to match <br />fascia color <br />Secure mechanical fastener <br />per site conditions <br />(installer to determine-- <br />UL Listed weatherproof <br />toggle disconnect <br />BEFORE <br />Existing Sign: 9'-3 3/4" (w) x 3-4 7/8" (h) 131.72 SF <br />Attachment: 1/4" X 4" Tapcon or <br />4" expansion/toggle. <br />Note: Painting by others Minimum 4 <br />AFTER <br />3/8" flexible <br />conduit (min.)FPARAPET IS LIKELY WOOD STUD FRAMED, V.I.F., ENSURE ATTACHMENT IS TO <br />UCTURA M4"MEMBER WITH 3" MIN. EMBEDDMENT USING 3/8" X 4" LAG SCREW I <br />Junction BoxOD STUD FRAMED 'j <br />120-277V electrical run <br />A <br />Conduit connecting , • • , E <br />lower and upper <br />raceways <br />• B <br />Additional backing <br />provided by client/GC _ •I <br />if required F _I <br />"Upper raceway must be at the top of the letters due to roof line location" <br />A B C D E F SgFt (ExF) <br />UBIF-CL-W-BP-RWY-21 1'-9" 11 1/8" 4'-013/16" 10'-713/16" 3-0 7/8" 11'-1 7/8" 34.2 <br />City of Everett Permit Review <br />Raceway access panel EVERETT Status: Reviewed for Permit <br />located on bottom for wA-l-T- <br />lower raceway 10/12/2023 10:27:02 AM <br />File Location: STND _ <br />Address: 505 SE Everett Mall Way Date: 07/25/23 <br />Drawing # y <br />Revisions: <br />U Underwriters <br />� <br />All dimensions are im erial <br />Added rcwy/increased. cxj. 20230818 <br />x <br />Drive/Clients/ CSTM <br />Revised per code &for accuracy I DM 9/1/23 <br />X <br />Laboratories, Inc. <br />unless specified metric. Items <br />i <br />OE 166145 <br />City/ST: Everett, WA <br />Designer: RF PM: AP <br />AS A CR O EN <br />x <br />x <br />Sign components to be in <br />are scaled as noted when <br />printed on an 11x17 sheet. <br />PRIORITY <br />x <br />x <br />x <br />x <br />strict UL compliance. <br />