Laserfiche WebLink
S2 Raceway Wired Illuminated Letterset on Backer <br />Remove existing illuminated letterset. Patch & paint facade (SW4064 <br />Pillowcase) to like new condition. Install new letterset as shown. <br />NOTE. No electrical penetrations can be made below the roofline. <br />All penetrations must be through parapet wall. Surface connection <br />from lower raceway to upper raceway will be necessary. <br />CODE NOTE: Wall sign greater of 48 SF or 15% of the area of the <br />building facade up to a maximum of 300 SF. <br />19 x 54 =1026 x 15% =153.9 SF Max <br />3" 4.5"-� <br />CROSS SECTION <br />(nts) <br />1" Black Jewelite trim cap <br />bonded to face <br />3" .040" aluminum <br />letter return, pre -coat black, <br />satin finish <br />3/16" #7328 <br />white acrylic letter face <br />electrical bushing <br />LED module <br />063" pre -coated white <br />aluminum backs <br />1/4" dia. weep holes <br />with light cover <br />.080" aluminum backer panel <br />painted Matthews N923SP Black, <br />satin finish <br />Pill Lightbox; <br />fabrication identical <br />to letters above <br />3/16" #7328 <br />white acrylic face with <br />first surface black vinyl <br />with copy weeded out <br />4.5" x 7" <br />Raceway (add weep holes); <br />typ. paint to match <br />fascia color <br />Secure mechanical fastener <br />per site conditions <br />(installer to determine) <br />UL Listed weatherproof <br />toggle disconnect <br />3/8" flexible <br />conduit (min.) <br />Junction Box <br />120-277V electrical run <br />Conduit connecting <br />lower and upper <br />raceways <br />Additional backing <br />provided by client/GC <br />if required <br />Raceway access panel <br />located on bottom for <br />lower raceway <br />Drawing # • . • .111111 Address: 505 SE Everett Mall Way Date: 07/25/23 <br />OE 1 166145 City/ST: Everett, WA <br />Designer: RF PM: AP <br />BEFORE <br />Existing Sign: 9'-3 3/4" (w) x 3-4 7/8" (h) 131.72 SF <br />A <br />AFTER <br />ubreakifixroofline <br />by osurion <br />4 <br />E <br />i <br />"Upper raceway must be at the top of the letters due to roof line location" <br />A B C D E F SgFt (ExF) <br />UBIF-CL-W-BP-RWY-21 1'-9" 11 1/8" 4'-013/16" 10'-713/16" 3-0 7/8" 11'-1 7/8" 34.2 <br />Revisions: <br />rue wcduon: a 1 rvU _ Added rcwy/increased. cxj. 20230818 X <br />Drive/Clients/ CSTM _ Revised per code & for accuracy I DM 9/1/23 X <br />X X <br />AS . CR O EN x x <br />X X <br />OUnderwriters <br />All dimensions are imperial <br />Laboratories, Inc. <br />unless specified metric. Items <br />are scaled as noted when <br />Sign components to be in <br />printed on an 11x17 sheet. <br />strict UL compliance. <br />PRIORITY <br />