ABBREVIATED SPECIFICATIONS <br />NOTE: NOT ALL SPECIFICATION SECTIONS MAY BE NEEDED FOR THIS PROJECT. CONTRACTOR TO APPLY SPEC, SECTIONS AS APPLICABLE TO SCOPE OF WORK. <br />GENERAL PLUMBING <br />NOTE: <br />CONTRACTOR" MEANS "PLUMBING CONTRACTOR" WHEN REFERENCED <br />ANYWHERE IN THE PLUMBING CONSTRUCTION DOCUMENTS UNLESS WORKAND <br />EQUIPMENT HAS BEEN COORDINATED BETWEEN THE PLUMBING AND GENERAL <br />CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", <br />"PROVIDE" AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT <br />DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO <br />MAKE A COMPLETE AND OPERATIONAL SYSTEM. <br />THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A <br />COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE PLUMBING <br />CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND <br />EQUIPMENT NECESSARY TO COMPLETE THE PLUMBING WORK. <br />PERMITS AND FEES <br />THE ITS <br />CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, <br />FEES AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING SCOPE OF <br />WORK. <br />WARRANTY <br />THE PLUMBING CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK <br />TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF <br />ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY ARCHITECT AND WILL <br />REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY, WITHOUT CHARGE AND <br />RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING <br />DEFECTIVE MATERIALS AND WORKMANSHIP. <br />PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT PLUMBING CODE, <br />STATE AND LOCAL CODES / ORDINANCES AND AHJ. ALL WORK SHALL ALSO BE <br />IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT <br />BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES AND AHJ, <br />THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL <br />APPLY. THE PLUMBING CONTRACTOR SHALL SATISFY CODE, AHJ, DRAWINGS <br />AND SPECIFICATIONS AS A MINIMUM STANDARD, WITHOUT ANY EXTRA COST. <br />THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK WITH <br />OTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE <br />OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE PLUMBING <br />DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. <br />SUBMITTALS: CONTRACTOR SHALL PROVIDE AN ELECTRONIC SUBMITTAL FOR <br />ALL PLUMBING FIXTURES, PUMPS, CONTROLS, INSULATION AND DEVICES. ALL <br />SUBMITTALS SHALL BE MARKED TO INDICATE WHERE THEY ARE USED AND WITH <br />THE DESIGNATION IN THESE PLANS. <br />PIPING <br />SOIL, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 ASS AND FITTINGS WITH <br />SOLVENT WELD. HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4 INCH PER <br />FOOT WHERE POSSIBLE BUT IN NO CASE LESS THAN 118" PER FOOT. APPLY TO <br />BUILDING DEPARTMENT FOR VARIANCE IF 1/8" IS NEEDED. COORDINATE WITH <br />AHJ FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH <br />INDIRECT WASTE TO FLOOR DRAINS. PROVIDE PIPED DRAIN TO SANITARY IF <br />REQUIRED BY AHJ. RELOCATE ANY VENTS NECESSARY TO GIVE 10 FOOT <br />CLEARANCE FROM HVAC INTAKE. COORDINATE WITH HVAC CONTRACTOR. <br />DOMESTIC WATER PIPING 2" AND SMALLER SHALL BE COPPER TUBE WITH <br />WROUGHT COPPER SWEAT FITTINGS JOINED WITH LEAD FREE SOLDER. <br />PROVIDE TYPE "L" COPPER TUBE ABOVE GROUND AND TYPE "K" BELOW <br />GROUND. ALTERNATIVELY, UPONOR PEX MAY BE USED WHERE NOT EXPOSED <br />AND CONCEALED. <br />CONDENSATE DRANAGE PIPNG: THE PLUMBING CONTRACTOR SHALL F&I <br />CONDENSATE DRAINS FOR AIR HANDLING UNITS, REFRIGERATION EQUIPMENT <br />AND ANY OTHER APPLICABLE EQUIPMENT. CONDENSATE DRAINAGE PIPING <br />SHALL BE SCHEDULE 40 PVC. <br />BASIC MATERIALS AND METHODS <br />PROVIDE ALL NEW MATERIAL AND FIXTURES UNLESS NOTED OTHERWISE. ALL <br />FIXTURES SHALL BE LABELED AND LISTED WHERE REQUIRED BY CODE AND AHJ <br />PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK <br />NECESSARY FOR THE INSTALLATION OF THE FIXTURE. HOWEVER, NO CUTTING <br />OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE <br />DONE WITHOUT THE CONSENT OF THE ARCHITECT, CONSTRUCTION MANAGER, <br />GC AND / OR OWNER. PROPERLY FILL, SEAL, FIREPROOF AND WATERPROOF <br />ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS AND CASEWORK. <br />CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED <br />BY OTHER TRADES AND NOTIFY OWNER'S REPRESENTATIVES OF ANY <br />DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS <br />ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE, ALL <br />DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING DIMENSIONS. <br />THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES <br />EQUIPMENT AND PIPING WILL BE INSTALLED AND SHALL REPORT ANY <br />CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE PLUMBING <br />WORK TO THE GC. <br />HANGERS & SUPPORTS: THE PLUMBING CONTRACTOR SHALL F&I ALL PIPE <br />SUPPORTS NEEDED FOR EQUIPMENT AND MATERIAL. ALL HORIZONTAL RUNS <br />OF PIPING SHALL BE SUPPORTED BY PIPE HANGERS SPACED NOT MORE THAN <br />10 FEET O.C. FOR PIPES 1-1/4" AND LARGER AND 8 FEET O.C. FOR PIPES <br />SMALLER THAN 1-1/4" AND AT EACH JOINT FOR SOIL OR WASTE PIPE. <br />ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE NEEDED TO PREVENT <br />SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED <br />WITH GALVANIZED COATINGS; NONMETALLIC COATED FOR HANGERS IN DIRECT <br />CONTACT WITH COPPER TUBING. <br />CONNECTIONS: INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL <br />CONNECT ON TO EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS <br />TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL <br />PIPING UP TO AND INCLUDING 1-1/2". WELD PIPING USE NON -LEAD, <br />NON -ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. <br />INSTALLATION: INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET <br />STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW V CLEANING <br />SPACE AROUND ALL PIPING, INCLUDING ANY ADDED PIPING INSULATION. <br />INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. <br />INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY <br />WALLS, GYPSUM -BOARD PARTITIONS, CONCRETE FLOOR AND ROOF SLABS / <br />STRUCTURE. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION <br />WITH FIRE -STOPPING SEALANT MATERIAL MEETING CODE, AHJ AND <br />ARCHITECT'S REQUIREMENTS. <br />BASIC MATERIALS AND METHODS (CONT.) <br />UNDERGROUND WATER AND SEWER LINES SHALL BE LAID IN SEPARATE <br />TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE AND <br />AHJ, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE <br />NEEDED FALL. <br />EQUIPMENT: THE PLUMBING CONTRACTOR SHALL VERIFY ANY EQUIPMENT <br />LOCATION AND SIZES REQUIRING PLUMBING CONNECTION(S) WITH THE TRADE <br />AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH -IN. <br />CLEANOUTS: F&I J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS <br />INDICATED ON THE DRAWINGS AND WHERE NEEDED IN ALL SOIL, WASTE AND <br />DRAIN LINES. IN AREAS WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE <br />CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH <br />RESILIENT FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, <br />NICKEL BRONZE TOP WITH TILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS <br />PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. <br />WHERE CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE <br />CONCEALED BEHIND CHROME PLATED ACCESS COVERS. <br />TESTING: ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE <br />THEY ARE BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE <br />PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS <br />REQUIRED BY AHJ. TEST WATER PURITY ACCORDING TO AHJ AND SUBMIT <br />CERTIFIED TEST RESULTS TO AHJ FOR REVIEW AND APPROVAL. <br />INSULATION <br />WATER PIPING: F&I THERMAL INSULATION ON ALL HOT & COLD WATER AND <br />HORIZONTAL WASTE PIPING IN CEILING SPACES AND ON ALL COLD WATER <br />PIPING IN CASEWORK AND BAR AREAS. USE SELF-SEALING CLOSED CELL FOAM <br />OR JACKETED FIBERGLASS INSULATION WITH MANUFACTURER APPROVED <br />ADHESIVES, SEALERS AND COATINGS. ALL MATERIALS USED SHALL HAVE A <br />FLAME SPREAD INDEX NOT MORE THAN 25 A SMOKE DEVELOPED INDEX NOT <br />MORE THAN 50. UNLESS OTHERWISE REQUIRED BY THE AHJ OR ENERGY <br />CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: <br />PIPE SIZE INSULATION THICKNESS <br />LESS THAN OR EQUAL TO 1-1/2" = 1" <br />2" DIA. OR GREATER = 1-1/2" <br />INSULATION VALUE = k VALUE NOT EXCEEDING 0.27 BTU " INCH/h'ft' F <br />SAFETY COVERS: INSTALL NO -SCALD SAFETY COVERS WITH INSULATED FOAM <br />LINER, TAMPER PROOF STRAP UNDER ADA SINKS AND WHERE REQUIRED BY <br />CODE. <br />ICE BIN DRAINS: INSULATE ICE BIN COPPER DRAIN LINES WITH 1/2"THICK, <br />SELF-SEALING, SECTIONAL, CLOSED CELL FOAM. <br />HVAC PIPING: INSULATE COOLING COIL PIPING AND CONDENSATE PIPING WITH <br />CODE & MANUFACTURER SIZED, SELF SEALING, CLOSED CELL FOAM. INSULATE <br />HVAC HOT AND CHILLED WATER PIPING SYSTEMS AND LOW PRESSURE STEAM <br />AND CONDENSATE PIPING WITH CODE & MANUFACTURER SIZED, HEAVY DUTY, <br />SELF SEALING, JACKETED FIBERGLASS. <br />VALVES <br />GENERAL: PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON <br />PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND <br />COMPONENT ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF <br />EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE <br />NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH <br />MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO <br />EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT <br />MOVING EQUIPMENT. PROVIDE STOP VALVES FOR ALL EQUIPMENT WHETHER <br />SHOWN ON THE DRAWINGS OR NOT. ALL VALVES SHALL BE RATED FOR A <br />MINIMUM OF 125 PSI OR GREATER (UNO). <br />IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI, THEN <br />PROVIDE A PRESSURE REGULATOR AT SERVICE ENTRY TO MAINTAIN WATER <br />PRESSURE (NOT NECESSARILY SHOWN ON DRAWINGS). PROVIDE BACKFLOW <br />PREVENTION AND MAINTAIN SERVICE IF REQUIRED BY AHJ. <br />NATURAL GAS <br />GAS: PROVIDE LISTED AND APPROVED GAS SHUT-OFF VALVE AT ALL GAS <br />APPLIANCES. PROVIDE GAS PRESSURE REGULATOR IF MEDIUM PRESSURE GAS <br />DISTRIBUTION AND INSTALL PER CODE WITH VENT PIPE TO EXTERIOR OF <br />BUILDING. <br />NATURAL GAS PIPING: PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL <br />PIPE WITH CAST, SCREWED FITTINGS. ALTERNATIVELY, PIPE FITTINGS MAY BE <br />OF THE PRESSED TYPE WITH THE FOLLOWING REQUIREMENTS: <br />1. FITTINGS AND SYSTEM SHALL BE MANUFACTURED BY VIEGA. <br />2. FITTINGS AND SYSTEM SHALL BE LISTED FOR NATURAL GAS PIPING, <br />EXTERIOR AND COMMERCIAL RATED. <br />3. CONTRACTOR TO PROVIDE CERTIFICATION ISSUED BY THE MANUFACTURER <br />INDICATING THEY HAVE PROPER TRAINING TO INSTALL THEIR SYSTEM. THIS <br />CERTIFICATION SHALL BE PROVIDED WITH SUBMITTALS OF THE PRESSED <br />FITTINGS TO BE USED. <br />COORDINATION WITH LANDLORD REQUIREMENTS <br />CONTRACTOR SHALL COORDINATE WITH LANDLORD FOR ANY LANDLORD <br />CONSTRUCTION REQUIREMENTS / SPECIFICATIONS. IF LANDLORD DOES HAVE <br />REQUIREMENTS, CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH <br />REQUIREMENTS/ SPECIFICATIONS AND ADHERE TO THEM. WHERE LANDLORD <br />REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS, <br />LANDLORD REQUIREMENTS SHALL GOVERN. <br />GENERAL NOTES <br />1. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR <br />TO CONSTRUCTION. <br />2. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, <br />CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME <br />DAMAGED DURING THE COURSE OF WORK. <br />3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR <br />ARRANGEMENT OF SYSTEM(S). FOLLOW DRAWINGS IN LAYING OUT WORK AND <br />CHECK DRAWINGS OF OTHER TRADES TO VERIFY SPACE CONDITIONS. <br />MAINTAIN HEADROOM AND SPACE CONDITION. <br />4. UNLESS OTHERWISE NOTED(SEE ARCH. SHEETS), THE CONTRACTOR SHALL <br />REMOVE ALL EXISTING PLUMBING FIXTURES INCLUDING PIPING AND ALL <br />OTHER MISC. DEVICES AS DIRECTED BY THE GC THAT IS NOT BEING SALVAGED <br />OR REUSED. EQUIPMENT / FIXTURES INDICATED ON DRAWINGS TO BE REUSED <br />SHALL BE INSPECTED AND IF DEFECTIVE, REPLACED. COORD. WITH GC AND <br />OWNER. <br />5. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO <br />ALL PLUMBING EQUIPMENT. <br />6. STOP VALVES AND / OR SHUT OFF VALVES SHALL BE INSTALLED AT ALL <br />PLUMBING FIXTURES AND APPLIANCES, EVEN IF NOT SHOWN IN PLANS. <br />7. ALL PIPING AND / OR PLUMBING DEVICES SHALL BE SUPPORTED FROM <br />STRUCTURE (NOT FROM EXISTING HVAC DUCTS OR PIPES). WASTE PIPING <br />SHALL BE HELD AS CLOSE TO STRUCTURE AS POSSIBLE. <br />8. COORDINATE PLUMBING ROUGH -IN AND CONNECTION REQUIREMENTS WITH <br />KITCHEN EQUIPMENT CONTRACTOR PRIOR TO ROUGH -IN WORK. <br />9. REFER TO PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION AND <br />REQUIREMENTS FOR PLUMBING CONTRACTOR. <br />10. PROVIDE ITEMS AND WORK AS REQUIRED TO COMPLETE THE INSTALLATION OF <br />PLUMBING SYSTEMS TO FIXTURES AND EQUIPMENT: TRAPS, STRAINERS, <br />GAUGES, GAS AND WATER PRESSURE REGULATORS, FLEXIBLE CONNECTIONS, <br />STOP VALVES, UNIONS, ETC. PROVIDE AND CONNECT PLUMBING PIPE FROM <br />ROUGH -INS TO ITEMS AS SHOWN, SPECIFIED AND REQUIRED. <br />11. CONTRACTOR IS RESPONSIBLE FOR CONFORMANCE TO ALL LOCAL CODES. <br />12. CLEAN FAUCET AERATORS AND PIPE STRAINERS BEFORE TURNING BUILDING <br />OVER TO OW NER. <br />13. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES. <br />PLUMBING ABBREVIATIONS <br />AFF <br />ABOVE FINISHED FLOOR <br />MAX <br />MAXIMUM <br />AHJ <br />AUTHORITIES HAVING <br />MECH <br />MECHANICAL <br />JURISDICTION <br />MC <br />MECHAN CAL CONTRACTOR <br />APPROX <br />APPROXIMATE <br />MOP <br />MAIN DISTRIBUTION PANEL <br />MEP <br />MECHANICAL, ELECTRICAL& <br />BLDG <br />BUILDING <br />PLUMBING <br />MFG <br />MANUFACTURER <br />CLG <br />CEILING <br />MIN <br />MINIMUM <br />CONST <br />CONSTRUCTION <br />MS <br />MOP SINK <br />CRL <br />COMBINED RAIN LEADER <br />CW <br />DOMESTIC COLDWATER <br />NIL <br />NIGHTLIGHT <br />NTS <br />NOT TO SCALE <br />DEG <br />DEGREES <br />DTL <br />DETAIL <br />OD <br />OVERFLOW DRAIN <br />ON <br />DOWN <br />OL <br />OVERFLOW RAIN LEADER <br />DWG(S) <br />DRAWING(S) <br />PS <br />PREP SINK <br />EA <br />EACH <br />POC <br />POINT OF CONNECTION <br />EC <br />IELECTRCAL CONTRACTOR <br />PM <br />PROJECT MANAGER <br />ELEC <br />ELECTR CAL <br />EM <br />EMERGENCY <br />RD <br />ROOF DRAIN <br />(E) OR (EX) <br />EXISTING <br />REF <br />REFERENCE <br />EXT <br />EXTERIOR <br />REQ('D) <br />REQUIRE(D) <br />REV <br />REVISED/REVISION <br />FD <br />FLOOR DRAIN <br />RL <br />RAIN LEADER <br />FS <br />FLOOR SINK <br />F&I <br />FURNISH &INSTALL <br />BHT <br />SHEET <br />FLR <br />FLOOR <br />SPECS <br />SPECIFICATION(S) <br />FT <br />FOOT/FEET <br />SF <br />SQUARE FEET <br />FCO <br />FLOOR CLEANOUT <br />SS <br />STAINLESS STEEL <br />GC <br />GENERAL CONTRACTOR <br />TEL <br />TELEPHONE <br />GFCI <br />GROUND FAULT CIRCUIT <br />TEMP <br />TEMPORARY <br />INTERRUPTER <br />TYP <br />TYPICAL <br />GW <br />GREASE WASTE <br />TMV <br />TEMPERATURE MIXING <br />VALVE <br />HR <br />HOUR <br />TW <br />TEMPERED HOT WATER <br />HVAC <br />HEATING VENTILATING & AIR <br />CONDITIONING <br />UNO <br />UNLESS NOTED OTHERWISE <br />HW <br />HOT WATER <br />HS <br />HAND SINK <br />V <br />VENT <br />HWS <br />HOT WATER SUPPLY <br />HWR <br />HOT WATER RETURN <br />W <br />SANITARY WASTE <br />WH <br />WATER HEATER <br />ILL <br />LANDLORD <br />WP <br />WEATHER-PROOF <br />LV <br />LOW VOLTAGE <br />WCO <br />WALL CLEANOUT <br />PLUMBING SHEET INDEX <br />Sheet List Table <br />Sheet Number <br />Sheet Title <br />P0.01 <br />PLUMBING SPECIFICATIONS <br />P2.01 <br />PLUMBING PLAN <br />P5.01 <br />PLUMBING DETAILS <br />P6.01 <br />PLUMBING SCHEDULES <br />PLUMBING LEGEND <br />NOTE: NOT ALL SYMBOLS MAY BE USED IN THESE DRAWINGS. <br />— — — DOMESTIC COLD WATER <br />DOMESTIC HOT WATER <br />DOMESTIC TEMPERED WATER <br />SANITARY WASTE <br />— — — — VENT <br />Iffi POINT OF CONNECTION <br />oH— PIPE UP <br />r� PIPE DOWN <br />Ip TEE UP <br />TEE DOWN <br />lD4 GATE VALVE <br />W BALANCING VALVE <br />131 BALL VALVE <br />d APPROVED GAS SHUT OFF VALVE <br />O WATER METER <br />4— WATER CONNECTION(STOP VALVE WHERE APPLICABLE) <br />HOSE BIBB <br />®® FLOORSINK <br />XX DETAIL MARK <br />PX.X <br />SHEET WHERE DETAIL IS SHOWN <br />OEQUIPMENT MARK - SEE SCHEDULE <br />SCOPE OF WORK <br />THIS PROJECT INCLUDES TENANT IMPROVEMENTS TO AN EXISTING RESTAURANT <br />SPACE. THE PLUMBING SYSTEMS ARE EXISTING AND ONLY BEING MODIFIED AS <br />INDICATED IN THESE PLANS. <br />tpP1�R C. <br />oQ a <br />504 K <br />o�sTgae° <br />SSJONAL <br />SHEET TITLE <br />PLUMBING <br />SPECIFICATIONS <br />Permit Set <br />P0.01 <br />