Laserfiche WebLink
FLOOR SINK SET FLUSH W/ TOP FIN. FLOOR <br />(CONTRACTOR TO CONFIRM W/ AHJ IF FLOOR <br />SINK IS TO BE ELEVATED ABOVE SLAB) <br />CAULK JOINT <br />THIN SET CERAMIC TILE, TYP. (COORD. W/ GC ON <br />TYPE OF FLOORING AND FLOOR SYSTEM, ETC.) <br />s <br />� sQQ•,� <br />Go 300 <br />• �,,sQQ•L <br />,p <br />)0(�1O°onnDUo <br />0 0000� <br />NO -HUB CONNECTION <br />_� <br />WASTE TO DRAIN <br />FLOOR <br />SINK <br />DETAIL NOT USED <br />DETAIL NOT USED <br />Scale: NTS <br />2 SCALE: NTS <br />Scale: NTS <br />SINK PIPE HANGER SUPPORT (OR PIPE <br />VENT IF REQUIRED BY CODE/AHJ CONNECT TO EQUIPMENT <br />CLAMP SUPPORT AS NEEDED) <br />TO OUTSIDE (DO NOT CONNECT <br />TO ANY SEWER VENT) INDIRECT DRAINS - TRAP IF REQUIRED PER CODE <br />OR AHJ. CONDENSATE DRAINS - TRAP <br />ABS INDIRECT DRAIN PIPE (SEE <br />PROVIDE CLEANOUTS IN REWIRED, INSTALL PER MANUF./CODE <br />TURNS/ENDS OF PIPE REQUIREMENTS <br />SERVICE VALVE <br />ABS THREADED COUPLING PLAN FOR SIZES) F&I ADDITIONAL <br />TO BASKET STRAINER OFFSETS AS MAY BE NEEDED <br />PIPE CLAMP SUPPORT AT DRAIN <br />PIPE MATERIAL SHALL BE PER THESE <br />CLEANOUTS AT ALL TERMINATION (& BLOCKING -NOT SHOWN) <br />PLANS AND/OR PER CODE. USE DWV <br />FITTINGS IF REQUIRED BY CODE/AHJ <br />P2_ 500 <br />CHANGES IN DIRECTION (IX2 <br />SLOPE PIPE PER CODE, <br />PRIMER VALVE <br />AS ALLOWED BY AHJ) <br />SEE PLANS) FOR SIZE(S) <br />DISCHARGE INTO OPEN AREA <br />ABS DWV FITTINGS (TYP.) <br />. OF FLOOR SINK W/ 2' AIR GAP <br />__;E�FLOOR <br />DISCHARGE INTO OPEN AREA OF FLOOR SINK <br />O (OR AS ALLOWED BY CODE) <br />u V.B. PORTS <br />FLOOR SINK W/ 2' AIR GAP <br />UNION <br />NOTES <br />NOTES: FLOOR SINK (OR FUNNEL DRAIN) <br />CONNECTION <br />1. F&I ALL WORK PER CODE AND AHJ REQUIREMENTS, EVEN IF NOT SPECIFICALLY SHOWN. <br />1. F&I ALL WORK PER CODE AND AHJ REQUIREMENTS, EVEN IF NOT SPECIFICALLY SHOWN. <br />SUPPLY UNE <br />2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPING SHALL BE MOUNTED <br />2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPING SHALL BE MOUNTED <br />MINIMUM <br />OFF THE FLOOR FOR CLEANING PURPOSES. <br />OFF THE FLOOR FOR CLEANING PURPOSES. <br />1/2' <br />3. ALL INDIRECT DRAIN DISCHARGES SHALL OCCUR OVER CLEAR AREA OF FLOOR SINK AND <br />3. ALL FLEXIBLE INDIRECT DRAIN LINES FOR APPLIANCES SHALL BE INSTALLED PER CODE/AHJ <br />COPPER <br />NOT OVER GATE. <br />AND MANUF. REQUIREMENTS. SUPPORT LINES SO THERE ARE NO SAGS OR DIPS IN LINE. <br />4. SLOPE ALL PIPES PER CODE AND F&i TRAPPED INDIRECT DRAIN AND VENT IF REQUIRED BY <br />CODE AND/OR AHJ (NOT SHOWN). <br />T Y P . C 0 N D E N S AT E / <br />INK INDIRECT DRAIN <br />EQUIP. INDIRECT DRAIN <br />PRIMER TRAP <br />� <br />n <br />n <br />4 Scale: NTS <br />J Scale: NTS <br />V Scale: NTS <br />NOTE: SCHEMATIC -ADAPT AS NEEDED FOR EXACT SITUATION. <br />(193) <br />RIFY"D, ITBID. <br />Z <br />N <br />2 ° °° <br />0 0 <br />W ° J S <br />W 5 0 <br />Co <br />J <br />a <br />2 <br />2 <br />W � <br />W <br />J <br />W <br />° o <br />a ,� <br />/1 J m <br />Y a F- Q <br />v U 3 <br />N <br />2 z Li N <br />W a >uj <br />0 <br />'L ; N <br />c?aE z C. <br />aQ a <br />504K <br />oys�ae° <br />SS�aNAL <br />w <br />Qz <br />w Qo <br />0 U z <br />w z (7 WK <br />m w <br />K W <br />Z m u <br />a I- Q a �w <br />REVISIONS <br />SHEET TITLE <br />PLUMBING DETAILS <br />Permit Set <br />,a. <br />DESIGNER john H-Iu, <br />CHECKED BY Chn.—I <br />SHEET <br />P5.01 <br />