My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 SE EVERETT MALL WAY ANGRY CRAB SHACK 2024-01-08
>
Address Records
>
SE EVERETT MALL WAY
>
1321
>
ANGRY CRAB SHACK
>
1321 SE EVERETT MALL WAY ANGRY CRAB SHACK 2024-01-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2024 7:22:11 AM
Creation date
11/8/2023 8:00:29 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1321
Tenant Name
ANGRY CRAB SHACK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATED SPECIFICATIONS <br />NOTE: NOT ALL SPECIFICATION SECTIONS MAYBE NEEDED FOR THIS PROJECT. CONTRACTOR TO APPLY SPEC. SECTIONS AS APPLICABLE TO SCOPE OF WORK. <br />GENERAL MECHANICAL <br />NOTE: <br />CONTRACTOR" MEANS "MECHANICAL CONTRACTOR" WHEN REFERENCED <br />ANYWHERE IN THE MECHANICAL CONSTRUCTION DOCUMENTS, UNLESS WORK <br />AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE MECHANICAL AND <br />GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. <br />"NEEDED", "PROVIDE" AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE <br />CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT <br />REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. <br />THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO VERIFY A <br />COMPLETE AND FULLY OPERATIONAL EXISTING MECHANICAL SYSTEM. THE <br />MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL <br />AND EQUIPMENT NECESSARY TO COMPLETE VERIFY THE FINAL OPERATING <br />CONDITIONS. <br />PERMITS AND FEES: THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY <br />FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE <br />MECHANICAL SCOPE OF WORK. <br />CODES: PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT <br />MECHANICAL CODE, STATE AND LOCAL CODES / ORDINANCES AND AHJ. ALL <br />WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN <br />CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, <br />ORDINANCES AND AHJ, THE MOST STRINGENT STANDARD (IN THE OPINION OF <br />THE ENGINEER) SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY <br />CODE, AHJ, DRAWINGS AND SPECIFICATIONS, AS A MINIMUM STANDARD, <br />WITHOUT ANY EXTRA COST. <br />THE MECHANICAL CONTRACTOR SHALL COORDINATE REQUIRED MECHANICAL <br />WORK WITH OTHER TRADES AND THE OWNER. <br />STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH <br />APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, <br />ASHRAE, NFPA, OTHER APPLICABLE AGENCIES AND AHJ, AS APPLICABLE TO <br />EACH INDIVIDUAL UNIT OR ASSEMBLY. <br />SITE EXAMINATION: THE MECHANICAL CONTRACTOR SHALL THOROUGHLY <br />EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK AND PIPING WILL BE <br />INSTALLED AND SHALL REPORT ANY CONDITION THAT PREVENTS THE PROPER <br />INSTALLATION OF THE MECHANICAL WORK. <br />AIR HANDLING EQUIPMENT & MATERIALS <br />ALL AIR HANDLING & HVAC SYSTEMS ARE EXISTING ARE INTENDED TO BE <br />RE -USED. THE CONTRACTOR SHALL INSPECT AND SERVICE THE EXISTING <br />SYSTEMS AND COMPONENTS NOTIFYING THE OWNER IF REPAIRS OR <br />REPLACEMENT OF EQUIPMENT OR SYSTEM COMPONENTS ARE NEEDED. <br />OPERATIONAL AIRFLOWS ARE CALLED OUT IN THE PERMIT DOCUMENTS. THE <br />CONTRACTOR SHALL VERIFY THAT THE EXISTING SYSTEM CAN MEET THESE <br />REQUIREMENTS. IF THERE ARE DEFICIENCIES THE CONTRACTOR SHALL NOTIFY <br />THE OWNER AND WORK WITH THE ENGINEER OF RECORD TO INITIATE SYSTEM <br />CHANGES TO RESTORE SYSTEMS TO AIRFLOWS AS NEEDED. <br />DUCTWORK AND ACCESSORIES <br />SHEETMETAL DUCTWORK: ALL DUCTWORK IS EXISTING AND SHALL BE <br />EXAMINED BY THE CONTRACTOR FOR COMPLETENESS AND CONDITION. <br />REQUIRED REPAIRS OR REPLACEMENTS SHALL BE PRESENTED TO THE OWNER. <br />CONTROLS <br />EXISTING CONTROLS SHALL REMAIN AND BE RE -USED. THE CONTRACTOR <br />SHALL TEST AND VERIFY - INFORMING THE OWNER OF DEFICIENCIES AND <br />POTENTIAL REPAIRS AND/OR REPLACEMENT. AWAIT INSTRUCTIONS BEFORE <br />PROCEEDING WITH CHANGES. <br />TESTING, ADJUSTING, AND BALANCING <br />KITCHEN VENTILATION SYSTEMS: <br />VERIFY THE AIRFLOWS (EXHAUST AND MAKEUP AIR) MATCH CFMS DEFINED IN <br />THESE PLANS. IF THEY DO NOT, NOTIFY THE OWNER AND FOR FOR FURTHER <br />INSTRUCTIONS. <br />RESTAURANT SEATING AREA HVAC SYSTEMS: <br />NO WORK IN THIS AREA <br />SYSTEM COMMISSIONING <br />NOT REQUIRED. <br />GENERAL NOTES <br />1. ALL MECHANICAL SYSTEM ARE EXISTING AND BEING REUSED. <br />MECHANICAL SHEET INDEX <br />Sheet List Table <br />Sheet Number <br />Sheet Title <br />M0.01 <br />MECHANICAL SPECIFICATIONS <br />M2.01 <br />MECHANICAL HVAC PLAN <br />M5.01 <br />MECHANICAL DETAILS <br />MECHANICAL ABBREVIATIONS <br />MECHANICAL LEGEND <br />NOTE: NOT ALL SYMBOLS MAY BE USED IN THESE DRAWINGS. <br />MAX <br />MAXIMUM <br />MECH <br />MECHANICAL <br />MC <br />MEP <br />MECHAN CAL CONTRACTOR <br />MECHANICAL, ELECTRICAL <br />TYP. SUPPLY DUCT UP/DN <br />MFG <br />AND PLUMBING <br />MANUFACTURER <br />ON UP <br />NJ DUCT HEATER <br />AFF <br />ABOVE FINISHED FLOOR <br />MIN <br />MINIMUM <br />F"T L TYP. RETURN DUCT UP/DN <br />MANUAL VOLUME DAMPER <br />AHJ <br />AUTHORITIES HAVING <br />JURISDICTION <br />NTS <br />NOT TO SCALE <br />ON UP <br />o BACK DRAFT DAMPER <br />m <br />APPROX <br />APPROXIMATE <br />OSA <br />OUTSIDE AIR <br />El: [a TYP. EXHAUST DUCT UP/DN <br />BAROMETRIC DAMPER <br />BLDG <br />BUILDING <br />umi DUCT SMOKE DETECTOR <br />PM <br />PROJECT MANAGER <br />TURNING VANES <br />CLG <br />CEILING <br />MOTORIZED DAMPER <br />CONST <br />CONSTRUCTION <br />REF <br />REFERENCE <br />CD <br />CEILING DIFFUSER <br />REQ('D) <br />REQUIRE(D) <br />O THERMOSTAT <br />COMBINATION SMOKE AND FIRE <br />REV <br />REVISED/REVISION <br />DAMPER <br />DEG <br />DEGREES <br />RG <br />RETURN GRILLE <br />DTL <br />DETAIL <br />O SENSOR <br />SPIN -IN TAKE -OFF AND VOLUME <br />ON <br />DOWN <br />SHT <br />SHEET <br />DAMPER <br />DWG(S) <br />DRAWING(S) <br />SPECS <br />SPECIFICATION(S) <br />y SUPPLY AIR ARROW <br />SF <br />SQUARE FEET <br />o-> UNDERCUT DOOR <br />EA <br />EACH <br />SS <br />STAINLESS STEEL <br />EC <br />ELECTRICAL CONTRACTOR <br />RETURNAIRARROW <br />ELEC <br />ELECTR CAL <br />TEMP <br />TEMPORARY <br />EM <br />EMERGENCY <br />TYP <br />TYPICAL <br />OR (EX)EXISTING <br />EX <br />EXT <br />EXTERIOR <br />UNO <br />UNLESS NOTED OTHERWISE <br />EG <br />EXHAUST GRILLE <br />WH <br />WATER HEATER <br />12 X 8 <br />INDICATES UNLINED 12" z 8" O.D. SHEETMETAL <br />F&I <br />FURNISH & INSTALL <br />(1ST FIGURE SIDE SHOWN <br />FLR <br />FLOOR <br />2ND FIGURE SIDE NOT SHOWN) <br />FOOI <br />� <br />GIC <br />GENERAL CONTRACTOR <br />HR <br />HOUR <br />�l�llll IIIIIIII <br />FLEXIBLE DUCT <br />HVAC <br />HEATING VENTILATING &AIR <br />CONDITIONING <br />NECK SIZE <br />ILL <br />LANDLORD <br />LV <br />LOW VOLTAGE <br />XX—X <br />DIFFUSER TYPE, REF. SCHEDULE <br />XXXX <br />DESIGN CFM (WHERE APPLICABLE) CFM <br />SHOWN FOR RETURN ARE UNOCCUPIED MODE <br />CEILING DIFFUSER (FLOW ARROWS SHOWN <br />O <br />INDICATE DIRECTION OF AIR FLOWS) <br />E� <br />CEILING RETURN / EXHAUST GRILLE <br />1 <br />M0.0 <br />DETAIL MARK <br />DETAIL MARK <br />MX X <br />SHEET WHERE DETAIL IS SHOWN <br />XXXXX <br />EQUIPMENT MARK - SEE SCHEDULE <br />PROJECT SCOPE OF WORK <br />AN EXISTING BUILDING SHALL BE REMODELED FOR NEW TENANT. TWO EXISTING TYPE <br />1 HOODS SHALL REMAIN, ONE SHALL BE RE -USED, THE OTHER ABANDONED IN PLACE. <br />EXISTING HVAC UNITS AND DUCTWORK TO REMAIN AS -IS. THE ONLY MECHANICAL <br />SCOPE IS START UP AND BALANCE VERIFICATION OF THE EXISTING TYPE I HOOD <br />SYSTEM (SEE PLANS): ALSO DUCT CLEANING AND OPERATIONAL CHECK OF SYSTEM IS <br />NEEDED PER THESE PLANS. <br />VICINITY MAP <br />B9th St SE <br />BothA Everett <br />T <br />91 st <br />e se <br />� n <br />93,d at SE <br />m <br />9nth at <br />m <br />BtR HI BE <br />B"tetq1at, vyal <br />OQ4ER C. <br />v <br />5504 hw4 <br />t Cc <br />s`SJONALO <br />Y <br />U <br />a <br />U) <br />R. <br />Q _ <br />W <br />W ao <br />'§ <br />o U � <br />0 Z <br />> 3 <br />LU z 0 k <br />w <br />0w Z�N� <br />�w <br />IL Q a w <br />REVISIONS <br />52 <br />a <br />b SHEETTITLE <br />MECHANICAL <br />SPECIFICATIONS <br />rermit bet <br />C.O. <br />CHECKED BY, chm <br />SHEET <br />M0.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.