My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1021 NORTH PARK DR 2023-11-28
>
Address Records
>
NORTH PARK DR
>
1021
>
1021 NORTH PARK DR 2023-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:47:09 PM
Creation date
11/9/2023 7:48:39 AM
Metadata
Fields
Template:
Address Document
Street Name
NORTH PARK DR
Street Number
1021
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL DATA <br /> OPER VOLTS* COMPR FAN MIN WIRE MIN WIRE MAX MAX MAX FUSE** <br /> UNIT SIZE V/PH MCA SIZEt SIZEt LENGTH LENGTHorCKT BRK <br /> MAX MIN LRA RLA FLA 60°C 75°C ft.(m)$ ft.(m)$ AMPS <br /> 60°C 75°C <br /> 018-A 48.0 9.0 0.50 11.8 14 14 67(20.4) 64(19.5) 20 <br /> 024-A 58.3 13.5 0.70 17.6 14 14 46(14.0) 43(13..l) 25 <br /> 030-A 64.0 12.8 0.70 16.7 14 14 44(13.4) 41 (12.5) 25 <br /> 036-A 208/230/1-60 253 197 77.0 14.1 0.50 18.1 12 12 57(17.4) 54(16.5) 30 <br /> 042-A 112.0 17.9 1.20 23.6 10 10 85(25.9) 81 (24.7) 40 <br /> 048-A 109.0 19.9 1.20 26.1 10 10 70(21.3) 67(20.4) 40 <br /> 060-A 1 1135.0 21.4 1.20 28.0 8 10 91 (27.7) 56(17.1) 40 <br /> *Permissible limits of the voltage range at which the unit will operate satisfactorily <br /> t If wire is applied at ambient greater than 30°C,consult table 310-16 of the NEC(NFPA 70). The ampacity of non-metallic-sheathed cable(NM),trade <br /> name ROMEX,shall be that of 60°C conditions,per the NEC(NFPA 70)Article 336-26.If other than uncoated(no-plated),60 or 75°C insulation,copper <br /> wire(solid wire for 10 AWG or smaller,stranded wire for larger than 10 AWG)is used,consult applicable tables of the NEC(NFPA 70). <br /> t Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%. <br /> **Time-Delay fuse. <br /> FLA -Full Load Amps <br /> LRA -Locked Rotor Amps <br /> MCA -Minimum Circuit Amps <br /> RLA -Rated Load Amps <br /> NOTE:Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. <br /> All motors/compressors contain internal overload protection. <br /> Complies with 2010 requirements of ASHRAE Standards 90.1 <br /> A-WEIGHTED SOUND POWER LEVEL (dBA) <br /> Unit Size- Standard TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) <br /> Voltage,Series Rating(dBA) 125 250 500 1000 2000 4000 8000 <br /> 018-A 73 49.5 58.5 64.5 69.0 63.0 59.5 52.4 <br /> 024-A 74 54.5 62.0 67.0 71.5 66.0 62.0 53.0 <br /> 030-A 74 56.0 62.5 66.0 68.5 64.5 61.0 53.5 <br /> 036-A 72 52.0 61.0 64.0 66.0 61.0 58.5 51.5 <br /> 042-A 74 56.5 61.5 65.0 1 66.5 63.5 61.0 56.5 <br /> 048-A 73 58.0 61.0 65.0 66.0 62.0 58.0 51.0 <br /> 060-A 74 56.5 62.5 66.5 68.0 63.0 59.5 51.5 <br /> NOTE: Tested in accordance with AHRI Standard 270-08(not listed in AHRI). <br /> CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) <br /> UNIT SIZE-VOLTAGE,SERIES REQUIRED SUBCOOLING°F(°C) <br /> 018-A 10(5.6) <br /> 024-A 10(5.6) <br /> 030-A 10(5.6) <br /> 036-A 10(5.6) <br /> 042-A 9(5.0) <br /> 048-A 10(5.6) <br /> 60 <br /> 9(5.0) <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.