Laserfiche WebLink
PM1-12 j+-'l + <br /> _,-PVMODULE MODULES I GENERAL ELECTRICAL P-A2EOA3 <br /> 40OW MICROINVERTER REF. QTY. MAKE AND MODEL PMAX PTC ISC I IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING NOTES <br /> PM1.12 12 HYUNDAI HIS-S400YH(BK) 40OW 376W 11.25A 10.61A 45.3V 37.7V -0.121V/°C(-0.27%/°C) 20A <br /> Q 0INVERTERS UTILITY HAS 24-HR UNRESTRICTED I I <br /> ANNA <br /> Q REF. QTY. MAKE AND MODEL AC VOLTAGE GROUND RATED POWER AX INPUT ACCESS TO ALL PHOTOVOLTAIC MAX OUTPUT CURRENT MAX INPUT CURRENT MVOLTAGE CEC WEIGHTED EFFICIENCY 1 � BLOSSOM SOLAR <br /> I I 11-12 1 12 1 ENPHASE IQ8A-72-2-US 240V NOT SOLIDLY GROUNDED 349W 1.45A 15.OA 60V 97.0% SYSTEM COMPONENTS LOCATED AT Ali <br /> 61 CI 61 C5 6 <br /> H H OCPDS PASS-THRU BOXES AND COMBINERS <br /> THE SERVICE ENTRANCE. <br /> 1 + 1 + Q REF. QTY. RATED CURRENT MAX VOLTAGE REF. QTY MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE CONDUCTORS EXPOSED TO <br /> cB1-2 2 15A 240VAC SUNLIGHT SHALL BE LISTED AS <br /> CBS 1 25A 240VAC JB1-2 2 TRANSITION BOX FOR 1 CIRCUIT 30A 240VAC 16000DC <br /> C1 1 ENPHASE IQ COMBINER 4W/IQ GATEWAY FOR 64A 240VAC 2 SUNLIGHT RESISTANT PER NEC <br /> PRODUCTION MONITORING ARTICLE 300.6(C)(1)AND ARTICLE <br /> I SYSTEM SUMMARY 310.10(D). <br /> I 1 1 BRANCH 1 BRANCH 2 RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2).PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY(DEFINED AS 3 FEET FROM THE POINT OF <br /> INVERTERS PER BRANCH 6 6 0 PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY)SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION.CONDUCTORS LOCATED CONDUCTORS EXPOSED TO WET <br /> JUNCTION BOX MAX AC CURRENT 8.70A 8.70A INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. LOCATIONS SHALL BE SUITABLE FOR <br /> L 1 JB1-2 MAX AC OUTPUT 2,094W 2,094W 3 <br /> r--� Q ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM,AS PER NEC 690.12(8)(2). USE IN WET LOCATIONS PER NEC <br /> ARRAY STC POWER 4,800W <br /> 2 3 ARRAY PTC POWER 4,516W 0 THE DC AND AC CONNECTORS OF THE ENPHASE I08A-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C).MATING CONNECTORS SHALL COMPLY ARTICLE 310.10(C). w <br /> MAX AC CURRENT 17A WITH NEC 690.33. U CD <br /> l AC COMBINER LLJ O <br /> I MAX AC POWER OUTPUT 4,188Wui <br /> L-- C1 DERATED AC POWER OUTPUT 4,188W Q THE ENPHASE IQ8A-72-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS(GEC)OR EQUIPMENT GROUNDING CONDUCTORS(EGC THE z <br /> r_ Al 1 BA 4 RATING INCLUDES GROUND FAULT PROTECTION(GFP).TO SUPPORT GFP,USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. ) GROUNDING NOTES w OQ <br /> I Q Q ALL EQUIPMENT SHALL BE 0 Q <br /> I 15A MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS.THEY ARE ROHS,OIL rte/ <br /> I RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL 3003 AND UL 9703. PROPERLY GROUNDED PER THE CO W <br /> I COMM 1 REQUIREMENTS OF NEC ARTICLES W W <br /> I GATEWAY ALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B)AND PART III OF <br /> I 4 © ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45.THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A)AND NEC 250.169 AND 250&690 <br /> SUBPANEL INSTALLED IN COMPLIANCE WITH NEC 250.64. PV MODULES SHALL BE GROUNDED Q c m <br /> I i CB3 I (E)GE MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE49.1VAT-6°C(-6.2°C-25°C)X-0.121V/C+45.3V=49.1 V). USING MODULE LUGS OR RACKING w c w <br /> L -� 25A 1201240V 10,3W <br /> ' 125ABUSAR(TOP-FED) ® ACAGGREGATIONPAN ELBUSBAR ANDTHEOVERCURRENT PROTECTI0NPROTECTINGTHEBUSBAR SHALL BESIZEDINACCORDANCEWITHNEC705.12(B)(3)(3). INTEGRATED GROUNDING CLAMPS <br /> F -J i 100A MAIN BREAKER 0 THE ENPHASE IQ COMBINER 4 CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 15A. Q J 00 �--J <br /> 1 2 AS ALLOWED BY LOCAL � � <br /> ' A PV BACKFEED OCPDS SHALL HAVE AN AMPERE INTERRUPTING CAPACITY THAT COMPLIES WITH THE REQUIREMENTS OF NEC 110.9 AND NEC 240.86(B) JURISDICTION.ALL OTHER EXPOSED <br /> I (E)100AI AAA <br /> �..�..� <br /> L___ _______i /V POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT,IN COMPLIANCE WITH NEC 705.12(8)(3)(1).OUTPUT IS BACKFED THROUGH BREAKER IN SUBPANEL.THE SUM OF 125%OF POWER METAL PARTS SHALL BE GROUNDED <br /> --- ------- /�'1 SOURCE(S)OUTPUT CURRENT(17A)AND THE MAIN BREAKER(100A)DOES NOT EXCEED THE BUSBAR RATING(125A).21A+100A<=125A USING UL-LISTED LAY-IN LUGS. �J <br /> r ' /'°� PV BREAKER MEETS NEC 690.12(C)REQUIREMENT FOR A RAPID SHUTDOWN INITIATION DEVICE INSTALLER SHALL CONFIRM THAT <br /> ' MAIN SERVICE PANEL <br /> -1- <br /> (E)SQUARE MOUNTING SYSTEM HAS BEEN <br /> _ I I 120124OV10,3w CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS <br /> E 2ooa 211ABUSBAR(TOP-FED) AMP. EVALUATED FOR COMPLIANCE WITH <br /> (E)EC L___ _______J 200A MAIN BREAKER CURRENT-CARRYING TEMP.CORR. CONT. MAX. DERATED TERM. TERM. 3 UL 2703"GROUNDING AND BONDING" <br /> G --- ---� ID TYP CONDUCTOR CONDUITICABLE CONDUCTORS IN OCPD EGC FACTOR FILL FACTOR CURRENT CURRENT BASE AMP. AMP TEMP. TEMP. LEN. V.D. <br /> CONDUIT/CABLE. (125%) RATING WHEN USED WITH PROPOSED PV <br /> KWHR ; UTILITY METER 12 AWG THHN/THWN-21NRATING MODULE. <br /> i 1 2 CABLE 2 15A 6 AWG BARE,COPPER 0.82(49°C) 1.0 8.7A 10.88A 30A 25A 900C 30A 78.7FT 0.56 <br /> I LINE I ENPHASEQCABLE,COPPER IF THE EXISTING MAIN SERVICE <br /> L___ 2 1 12 AWG THWN-2,COPPER 0.75'DIA.EMT 2 15A 12 AWG THWN-2,COPPER 1.0(27°C) 1.0 8.7A 10.88A 30A 30A 75'C 25A 46.3FT 0.66% <br /> 3 1 12 AWG THWN-2,COPPER 0.75'DIA.EMT 2 15A 12 AWG THWN-2,COPPER 1.0(27°C) 1.0 8.7A 10.88A 30A 30A 75'C 25A 31AFT 0.45% PANEL DOES NOT HAVE A <br /> 4 1 8AWG THWN-2,COPPER 0.75"DIA.EMT 2 25A 10 AWG THWN-2,COPPER 1.0(27°C) 1.0 17.4A 21.75A 55A 55A 75-C 50A 29.2FT 0.33% VERIFIABLE GROUNDING <br /> 4 ELECTRODE,IT IS THE <br /> CONTRACTOR'S RESPONSIBILITY TO <br /> INSTALL A SUPPLEMENTAL <br /> GROUNDING ELECTRODE. <br /> AC SYSTEM GROUNDING <br /> ELECTRODE CONDUCTOR(GEC) <br /> 5 SHALL BE A MINIMUM SIZE#8AWG <br /> WHEN INSULATED,#8AWG IF BARE <br /> WIRE. <br /> EQUIPMENT GROUNDING <br /> CONDUCTORS SHALL BE SIZED <br /> ACCORDING TO NEC ARTICLE 690.45, SINGLE-LINE DIAGRAM <br /> 6 AND BEA MINIMUM OF#10AWG <br /> WHEN NOT EXPOSED TO DAMAGE, PROJECT ID: COEB4F-1 <br /> AND#6AWG SHALL BE USED WHEN DATE: 1118123 <br /> EXPOSED TO DAMAGE CREATED BY: K.P. <br /> GROUNDING AND BONDING <br /> CONDUCTORS,IF INSULATED,SHALL CHECKED BY: P.H. <br /> 7 BE COLOR CODED GREEN,OR REVISIONS <br /> MARKED GREEN IF#4AWG OR <br /> LARGER <br /> SINGLE-LINE DIAGRAM <br /> PV-3 SCALE: NTS PV-3 <br />