Laserfiche WebLink
Drew Martin <br /> From: Grace Lounsbury <Grace.Lounsbury@MG2.com> <br /> Sent: Thursday, February 3, 2022 12:58 PM <br /> To: Drew Martin <br /> Cc: Angela Balmer <br /> Subject: [EXTERNAL] RE: City of Everett Permit Services: 6617 Associated Blvd (B2107-038) - <br /> Revision after Issuance <br /> CAUTION:This email originated from outside of the organization. Do not click links or open attachments unless you <br /> recognize the sender and know the content is safe. <br /> Thank you Drew, <br /> Per this email I can confirm that is all correct and we do not need the permit revision.Thank you!! <br /> Grace Lounsbury RA <br /> Associate <br /> MG2 <br /> 206-962-6694 <br /> From: Drew Martin <dmartin@everettwa.gov> <br /> Sent:Thursday, February 03, 2022 12:55 PM <br /> To: Grace Lounsbury<Grace.Lou nsbury@MG2.com> <br /> Subject: City of Everett Permit Services: 6617 Associated Blvd (B2107-038)- Revision after Issuance <br /> Hello, Grace. <br /> This email recaps our discussion regarding the submitted revision. We require you to reply with a confirmation of the <br /> information stated herein and approval to void the submitted revision. The following approval to perform work applies <br /> to the proposed scope-of-work(SOW) described herein, and shall not be understood or otherwise construed to approve <br /> other work, whether or not similar in scope or nature,to proceed without first obtaining specific authorization from the <br /> City of Everett Permit Services (City). <br /> Per our telephone discussion today, it was clarified that the proposed SOW revisions are limited to a temporary <br /> construction condition. The temporary condition involves constructing three vehicle openings (approximately 12.5'x10') <br /> by demolishing openings through an interior non-structural, non-bearing metal stud wall on Grid L.I. Based on this <br /> SOW, we do not require the issued permit to be revised. The proposed SOW is a temporary condition and is considered <br /> as contractor means-and-methods to perform the work included in the approved construction drawings for this <br /> permit. The associated temporary roll-up door and mechanical ventilation similarly do not require a permit. Any and all <br /> associated electrical work should be performed under a valid permit associated with the approved building permit. <br /> The contractor shall obtain signed and sealed details prepared by the architect-of-record (AOR)and engineer-of-record <br /> (EOR)to repair the openings and return the wall to its pre-existing condition. The strength and performance of the wall <br /> shall be equal or greater to its original condition, and shall comply with all requirements of the building code in effect fo r <br /> this project. These details do not need to be submitted to the City for review unless requested by the building <br /> inspector. The contractor shall coordinate with the building inspector on-site during one of the regularly scheduled <br /> inspections, prior to closing the openings, and provide a copy of this correspondence. <br />