My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5118 SEAVIEW WAY 2023-11-28
>
Address Records
>
SEAVIEW WAY
>
5118
>
5118 SEAVIEW WAY 2023-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2023 11:56:50 AM
Creation date
11/14/2023 6:25:00 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAVIEW WAY
Street Number
5118
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
im Ism- s-C <br /> MATERIALS TESTING&CONSULTING,INC. <br /> Bob Reese - Foundation Repair - 22BO23 - Field Report: Concrete: Report <br /> #F274502 <br /> CLIENT Bob Reese DATE 02/01/2022 <br /> PROJECT LOCATION 5118 Seaview Way Everett WA 98225 PERMIT #B2111-026 <br /> Inspection Information: <br /> Inspection Date: Time Onsite: 10:00 Weather 40 Overcast <br /> 02/01/2022 AM Conditions: <br /> Inspection Performed: Concrete <br /> Subcontractor: Matvey Foundation Repair Continuous or Periodic: Continous <br /> Sheets: S2.0 Location/Area: New Footings <br /> Details: N Level/Elevation: Surface existing garage <br /> Approved Plans Dated: <br /> Remarks: <br /> CONCRETE PLACEMENT: Continuous Inspection <br /> Drawings indicate that they conform to 2015 IBC, Seismic Design Category D. <br /> MTC inspector on site, as requested, to observe the placement of approximately 2 CY of concrete supplied by Standwood <br /> ready Mix into footings at the location noted above. <br /> One set of five (4"x 8") cylinders was cast for compressive strength test specimens. <br /> Concrete was placed via wheelbarrow,was mechanically consolidated with mechincal vibrator, and finished by hand <br /> To the best of MTC inspector's knowledge, the above-described work was performed in general accordance with project <br /> specifications and approved plans. <br /> Images: <br /> Ll <br /> 04 <br /> P P".TO W I COLUMN <br /> UPLOADED: 02/01/2022 14:03:22 UPLOADED: 02/01/2022 14:03:23 <br /> As a mutual protection to clients,the public and ourselves,all reports are submitted as the confidential property of clients,and authorization for publication of statements,conclusions or extracts from or regarding our reports is reserved pending our written approval. <br /> Environmental•Geotechnical Engineering•Special Inspection•Non-Destructive Testing•Materials Testing <br /> BurlingtonjOlympia IBellinghamlSilverdaleITukwila <br /> 360.755.1990 <br /> www.mtc-inc.net <br /> Bob Reese-Foundation Repair-22B023,02/0112022,#F274502,Page 1 of 2 <br />