ol <br /> HA LAK VI W T RRAC APARTM NTS <br /> � G <br /> � 0 10 <br /> CD <br /> FIRE ALARM SYSTEM W <br /> yw <br /> EVERETT, WASHINGTON oQ <br /> oo � <br /> SHEET # SHEET TITLE ai a <br /> qD <br /> FA-01 SYSTEM INFORMATION <br /> FOR SIEMENS SYSTEM: <br /> FA-02 TYPICAL WIRING & MOUNTING DETAILS DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED <br /> QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT <br /> WITH DEVICES ADDRESS. <br /> FA-03 SYSTEM CALCULATIONS FIRE ALARM FC901-U3 SIEMENS FH901-R3 66" A.F.F. <br /> NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS 1 FACP CONTROL PANEL TO TOP <br /> FA-04 BASEMENT & FIRST FLOORS FIRE ALARM LAYOUTS DEVICE 1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. m <br /> © REMOTE BOOSTER PAD-5-9A SIEMENS PAD-S-ENCL 66" A.F.F. <br /> 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 2 "a POWER SUPPLY To TOP t <br /> FA-05 SECOND FLOOR FIRE ALARM LAYOUT & RISER DIAGRAM SMOKE DETECTOR OP921 W/ SIEMENS 4S DEEP CEILING <br /> 3 BRDANCHWGSSAPERM CIRCUIT <br /> WIRING IS SUPERVISED. NO PARALLEL 2 O (ADDRESSABLE-PHOTO) DB-11 BASE W/ 1G RING <br /> 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL HEAT DETECTOR H1921 W/ SIEMENS 4S DEEP CEILING <br /> ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 4 �" (ADDRESSABLE) DB-11 BASE W/ 1G RING o <br /> 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, DUAL OPTICAL/H/CO OOHC941 W/ SIEMENS 4S DEEP CEILING <br /> SHEET INDEX STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) 23 s " (ADDRESSABLE-PHOTO) ABHw-4s BASE w/ 1G RING <br /> ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. R w <br /> MANUAL PULL STATION XMS-D SIEMENS 4S DEEP 48" A.F.F. w o <br /> 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT 8 ❑F (ADDRESSBLE) W/ 1G RING TO CENTER w <br /> AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 FIRE ALARM <br /> 43 �p LOW FREQUENCY LFS-F-W SIEMENS 4S DEEP 80" A.F.F. a <br /> 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, SOUNDER W/ IG RING TO BOTTOM o <br /> TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, WP FIRE ALARM SYSEM SENSOR PROVIDED 80" A.F.F. <br /> AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. (7)E HORN/STROBES, WP P2WK 80 BOTTOM <br /> N <br /> TYPE OF WORK: BUILDING FIRE ALARM SYSTEM E (EXISTING) <br /> 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED <br /> END-OF-LINE <br /> DRAWINGS FOR "AS BUILT" PURPOSES. -- RESISTOR a N <br /> o � <br /> REPLACE EXISTING WIRELESS CWSI SYSTEM WITH HARDWIRED SIEMENS ADDRESSABLE SYSTEM. 9. FOR SDDINONALD/OR INSTALLATION <br /> INSTRUCTIONS, REFER TO CATALOG CUT 6 BATTERY <br /> AT ERAH SLA1270 PCIFICBATTERIES WER <br /> HEAT DETECTORS WILL BE REPLACED WITH COMBINATION SMOKE/HEAT/CO DETECOTORS WITH LOW FREQUENCY BASES. aQaa <br /> EXISTING EXTERIOR HORN/STROBES WILL BE INTERFACED TO NEW PANEL. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS <br /> NEW PULL STATION WILL BE INSTALLED BY FIRE PANEL. MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, <br /> SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER <br /> SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT <br /> SCOPE OF WORK DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. O <br /> 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT <br /> OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 0 <br /> 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE z <br /> ACTIVATION DEVICE. Lu <br /> 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. Q <br /> WIRE SCHEDULE AND CONDUIT FILL CHART <br /> WIRE DESIGNATION 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY Q <br /> GENERATOR. a <br /> 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER Q g co <br /> SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. U LU H 0 <br /> EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION U)wcro O <br /> A ANNUNCIATOR NETWORK TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) FOR PROTECTION DURING CONSTRUCTION. >_c <br /> D DATA LINE - ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL Q U)P� U. <br /> P POWER Two #14 FPLR RED (JACKET) TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 2 <br /> S SIGNALING CIRCUIT - FEED TWO #14 FPL/FPLR RED (JACKET) CHAPTER 7. W g F-W �J <br /> S, SIGNALING CIRCUIT - RETURN TWO #14 FPL/FPLR RED (JACKET) 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT W Cocc <br /> w L <br /> T NAC TRIGGER Two #14 FPLR RED (JACKET) AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR g; 7 W <br /> CONDUIT FILL CHART OTHER BACK BOXES OF DIFFERENT CIRCUITS. w LL <br /> 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND <br /> No. of covoucroRs VOLTS WIRE slzE TYPE DIMENSIONS AREA AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO w <br /> TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 FINAL EQUIPMENT TRIM. Y <br /> TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 <br /> TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A ui <br /> PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. <br /> CONDUIT FILL 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE <br /> CALCULATE: THE: TOTAL AREA of THE: WIRE BEING RUN IN THE: CONDUIT FROM THE: TABLE: OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES w <br /> ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM AFTER COMPLETION OF THEIR INSTALLATION. <br /> THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. T <br /> 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH I_ <br /> CONDUIT SIZE MAXIMUM FILL IT IS LOCATED. (V/,� <br /> 1/2'„ .12 SQUARE INCH 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. <br /> 3/4 .21 SQUARE INCH <br /> 1" IN <br /> .34 SQUARE CH SCALE:NOT TO SCALE <br /> 1-1/4" .60 SQUARE INCH DRAWN BY: <br /> 1-1'�2" .82 SQUARE INCH C. ENGSTFELD <br /> 21.34 SQUARE INCH <br /> AARON E. MAUS DESIGNED BY: <br /> FIGURES ARE BASED ON 409 CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. NICET LEVEL III L. ALLEN <br /> DATE:06/16/23 <br /> CERT. #133903 EXP. 03/01/2024 BACKROUND PLAN PROVIDED BY <br /> SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED <br /> THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END JOB NUMBER:69966-1 <br /> SHEET <br /> WIRE DESIGNATION GENERAL NOTES SYMBOLS LEGEND FA-01 <br /> Proprietary & Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved <br />