Step 6: Elevators PASS FAIL N/A <br /> 1. Elevator Technician- Elevator technician must be on site for the following test to ❑ ❑ ❑ <br /> take place. <br /> 2. FACP-Actuation from the elevator hoistway, elevator machine room, elevator ❑ ❑ ❑ <br /> machinery space, elevator control space, or elevator control room smoke <br /> detectors, or other automatic fire detection shall cause a separate and distinct <br /> visible annunciation at the building FACP and remote annunciators to alert fire <br /> fighters that the elevators are no longer safe to use. <br /> 3. Recall-Test detector(s) located at elevator lobby that will initiate elevator recall: ❑ ❑ ❑ <br /> (Elevator lobby detectors must be within 21 feet of each elevator door.) <br /> • Verify recall to a primary floor <br /> • Verify recall to alternate floor <br /> • Verify illumination of"Fire Hat" <br /> 4. Machine Room Detector-Test detector(s) located in shaft & elevator machine <br /> room: <br /> • Verify recall to designated floor <br /> • Verify flashing illumination of"Fire Hat" <br /> 5. Heat Detectors- Heat Detectors installed in a shaft or machine room and used for ❑ ❑ ❑ <br /> shunt trip (shut down elevator power) activation shall be located within 2 feet of <br /> each sprinkler head and have both a lower temperature rating and a higher <br /> sensitivity as compared to the sprinkler. <br /> Step 7: Initiation Devices PASS FAIL N/A <br /> 1. FACP-Test individual devices to ensure proper operations and annunciation at the ❑ ❑ ❑ <br /> panel with the correct device location. <br /> Smoke Detectors: <br /> 2. Sample Test-The fire inspector will select a sample of Smoke Detectors at ❑ ❑ ❑ <br /> random to be tested by using smoke or a listed aerosol. (minimum of one per floor <br /> and no less than 10%of the devises shall be tested) <br /> 3. Trouble-The fire inspector will select a minimum of one smoke detector at ❑ ❑ ❑ <br /> random to be disconnected to verify a trouble signal is received at the FACP. <br /> 4. Addressable-All smoke detectors are addressable models. ❑ ❑ ❑ <br /> 5. Wall Mount-Wall-mounted smoke detectors must be installed between 4 and 12 ❑ ❑ ❑ <br /> inches from the ceiling measured to the nearest edge of the detector. <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 I Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.