My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4920 COLBY AVE 2023-11-28
>
Address Records
>
COLBY AVE
>
4920
>
4920 COLBY AVE 2023-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2023 2:54:20 PM
Creation date
11/17/2023 6:38:35 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4920
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifically: 1) the system is designed for the local wind speed; 2) the ground snow load does not exceed 70 psf; 3) <br /> the total dead load of all items is less than 4 psf (actual value is approximately2.65 psf); 4) Modules are not <br /> mounted more than 18" off the roof; and 5) Supports are installed such that the dead load is spread across roof- <br /> framing members and does not exceed 50 lbs at any point. <br /> Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading <br /> has been used to verify the adequacy of the connection specified above. Connection locations should be in <br /> accordance with design drawings. <br /> Conclusion <br /> The roof structure need not be altered for either gravity or lateral loading. Therefore, the existing structure is <br /> permitted to remain unaltered. Connections to the roof must be made per the "Roof Connection Details" section <br /> above. Copies of all relevant calculations are enclosed. <br /> Limitations and Disclaimers <br /> The opinion expressed in this letter is made in reliance on the following assumptions: the existing structure is in <br /> good condition; the existing structure is free from defects in design or workmanship; and the existing structure was <br /> code-compliant at the time of its design and construction. These assumptions have not been independently <br /> verified, and we have relied on representations made by the property owner and his or her agents with respect to <br /> the foregoing. The undersigned has not inspected the structure for patent or latent defects. <br /> Electrical engineering is beyond the scope of this analysis. Solar panels must be installed per manufacturer <br /> specifications. Structural design and analysis of the adequacy of solar panels, racks, mounts, rails, and other <br /> components is performed by each component's respective manufacturer and the undersigned makes no statement <br /> of opinion regarding such components. This letter and the opinions expressed herein are rendered solely for the <br /> benefit of the permitting authority (city or county building department), and may not be utilized or relied on by any <br /> other party. <br /> If you have any questions or concerns, please contact our office at (855)-709-1181, or email <br /> Austen.Morfin@solgenpower.com. <br /> Sincerely, <br /> Trevor A. Jones, P.E. <br /> OR <br /> A\ 0o N Ns/N <br /> F0 <br /> z <br /> 201148 8 Q7 <br /> RFGIs \� <br /> FSS/ONAUEN� <br /> 10/6/2023 <br />
The URL can be used to link to this page
Your browser does not support the video tag.