Laserfiche WebLink
r <br /> INSTALLATION AND MAINTENANCE INSTRUCTIONS SILENT W <br /> 4/0 KNIGHT o <br /> by Honeywell <br /> 7550 Meridian Circle,Maple Grove,MN 55369-4927 <br /> 763-493-6455;800-328-0103 Fax:763-493-6475 <br /> SK-Monitor Module http://www.silentknight.com <br /> SPECIFICATIONS <br /> Normal Operating Voltage: 15 to 32 VDC <br /> Maximum Current Draw: 5.0 (LED on) usAverage Operating Current: 375pA pA(group poll),350 pA(direct poll),600 pAmps(communication,ID oi� <br /> EOL Resistance: 47K Ohms <br /> Max.IDC wiring resistance: 1,500 Ohms <br /> Maximum IDC Voltage: 11 Volts �On� <br /> Maximum IDC Current: 450pA MAR 1 ii L <br /> Temperature Range: 32°F to 120°F(0°C to 49°C) <br /> Humidity: 10% to 93% Non-condensing p��� �' <br /> Dimensions: 41/2"H x 4"W x 11/4"D(Mounts to a 4"square by 21/8"deep box.) (�'(T'Y OF EVE <br /> Accessories: SMB500 Electrical Box v+1 S�rVICBS <br /> permit <br /> BEFORE INSTALLING FIGURE 2.MODULE MOUNTING: <br /> This information is included as a quick reference installation guide.Refer to NOTE:For UL Listed security installations,the SK-Monitor must be mounted <br /> the control panel installation manual for detailed system information. If the within the control panel enclosure. <br /> modules will be installed in an existing operational system,inform the opera- <br /> tor and local authority that the system will be temporarily out of service.Dis- ®®j <br /> connect power to the control panel before installing the modules. �� ` <br /> NOTICE:This manual should be left with the owner/user of this equipment. \ �!' <br /> a / �- <br /> GENERAL DESCRIPTION I 4�e•7 �,� <br /> The SK-Monitor Module is intended for use in intelligent,two-wire systems, \ <br /> where the individual address of each module is selected using the built-in fti <br /> rotary switches.It provides either a Class A or Class B fault tolerant initiating <br /> device circuit(IDC)for normally open contact fire alarm and supervisory de — <br /> vices,or either normally open or normally closed security devices.The mod- /'_ I <br /> ule has a panel controlled LED indicator. ® �1t'''. ISOLATED <br /> COMPATIBILITY REQUIREMENTS I , . ,� QUADRANT <br /> To ensure proper operation,this module shall be connected to a compatible <br /> Silent Knight system control panel(list available from Silent Knight). I '...oi <br /> FIGURE 1.CONTROLS AND INDICATORS: <br /> I <br /> n n 1 . 0 0 % <br /> 4\ O <br /> d' Oe o . *I0 <br /> © C. <br /> C1066-00 <br /> WIRING <br /> T9 T2 NOTE: All wiring must conform to applicable local codes, ordinances, and <br /> regulations.This module is intended for power limited wiring only. <br /> T8 T3 <br /> 1. Install module wiring in accordance with the job drawings and appropri- <br /> T7 7 = - ^= - T4 ate wiring diagrams. <br /> T8 g`4� -,'= — 2. Set the address on the module per job drawings. <br /> K o 3. Secure module to electrical box(supplied by installer),as shown in Figure 2. <br /> cc- = TENS A ONES Qrammi() <br /> U o <br /> • <br /> U <br /> C1067-00 <br /> MOUNTING <br /> The SK-Monitor mounts directly to 4-inch square electrical boxes(see Figure <br /> 2).The box must have a minimum depth of 21/8 inches.Surface mounted elec- <br /> trical boxes(SMB500)are available from Silent Knight. <br /> SK-460-013 1 I56-3442-000 <br />