Laserfiche WebLink
BOEING COMMERCIAL AIRPLANE GROUP <br /> EVERETT FIRE PANEL REPLACEMENT Permit ti RA11202308 <br /> Site Address: 3003 W.Casino RD 45-205 <br /> Applicant: Alexander Gow <br /> Application Date:5/11/2023 <br /> Description: Replace Sprinkler Monitoring Panel <br /> BUILDING 45-205 Review Status tat Review by City&Peer Reviewers <br /> Review Date: 5/17/2023 <br /> L sT <br /> EVERETT `„�..RS�" <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 05/17/2023 12:16:17 <br /> PM <br /> BOEING EVERETT FACILITY <br /> 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 <br /> MICINITY MAP LOCATION MAP SITE PLAN INDEX OR DRAWINGS <br /> GENERAL <br /> • 45-205—GO GO COVER SHEET — 04.28.23 <br /> BOEING EVERETT FACILITY ELECTR�GAL <br /> • 45-205-LOA EOA ELECTRICAL LEGEND & ABBREVIATIONS A 04.28.23 <br /> • 45-205-E260 E260 BUILDING 205 FIRE ALARM SYSTEM PLAN A 04.28.23 <br /> PROJECT <br /> LOCATION • 45-297-E60 E60 BUILDING 297 FIRE ALARM SYSTEM PLAN A 04.28.23 <br /> MREFr • 45-205—E506 E506 FIRE ALARM SYSTEM DETAILS A 04.28.23 <br /> U F- F- 45-6 <br /> 4, 45-52 <br /> F 5 <br /> 101 <br /> 45-6 <br /> 45-0345-04 <br /> EXISTING MAJOR 102 <br /> G BOEING FACIUDES <br /> P O D ,103 45-997 1 <br /> Cl Y I� <br /> 45-999 <br /> 9 0 <br /> N 9� 104 45-99 45-06 <br /> ELLEVUE 118 45-02 <br /> los <br /> aE 90 c� Qn <br /> o eo <br /> RENTON <br /> 7 ® J ..w� s 107 .1 6.e <br /> KENT <br /> gAI IT o o- ins 19e POND <br /> UBURN M LLLIIII o_s6 o g <br /> 0 5 10 ® E3 �- 201 °4s-5a <br /> — TACOMA 40_� <br /> Y <br /> PDGF EER DESCRIPTION OR WORK <br /> I <br /> THE SCOPE OF THIS PROJECT IS TO UPGRADE THE EXISTING BUILDING FIRE ALARM SYSTEM. <br /> m *NOTE BUILDING 205 FACP PROVIDES DETECTION FOR BUILDINGS 205 & 297. <br /> PROJECT SITE THE WORK TO BE PERFORMED INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: <br /> 1. REMOVE OLD FOCUS PANEL, AND ASSOCIATED HARDWARE. PROVIDE AND INSTALL NEW DIGITAL <br /> �fR ADDRESSABLE BUILDING FACE. <br /> oPop 2. PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDING FACE. SEE SHEET E506 FOR <br /> INSTALLATION DETAILS. <br /> FrINE FIELD a� oFIR LAKE <br /> 3. INSTALL NEW SMOKE DETECTOR ABOVE FACE. <br /> 4. REPLACE EXISTING FIRE ALARM DEVICES WITH NEW COMPATIBLE DEVICES IN BUILDING 203. SEE <br /> _ TY5 SNOHOMI COU _ I SHEET 1E260 FOR INSTALLATION DETAILS. <br /> N PROJECT SITE cul 5. REPLACE EXISTING FIRE ALARM DEVICES WITH NEW COMPATIBLE DEVICES IN BUILDING 297. SEE <br /> o �' �\ [III�IIIIIIII SHEET 1E60 FOR INSTALLATION DETAILS. <br /> 6. PROVIDE AND INSTALL NEW HORN/STROBE. <br /> wm <br /> PROJECT TEAM <br /> 3 OWNER: BOEING EVERETT FACILITY ELECTRICAL: BOEING EVERETT FACILITY <br /> \ N N N 3003 WEST CASINO ROAD 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 EVERETT, WASHINGTON 98203 <br /> PROJECT MANAGER: RAY RIMORIN PROJECT MANAGER: LARRY HILL <br /> TEL: 425.330.1807 TEL: 425.328.5309 <br /> m A SUBTITLE CURRENT REVISION SYMBOL GATE <br /> 3 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY N <br /> THIS DESIGN AND�OR CHECKED COVER SHEET A 04.28.23 0 <br /> NEW FIRE MONITORING PANEL REPLACEMENT 27851053 MDK TT 07.22.22 a <br /> Ym SPECIFICATIONIs APPRovED N IN TITLE EVERETTFIRE PANEL REPLACEMENT G� <br /> 0 A SHOP DRAWINGS AGOW/J$ 04.28.23 BOE//VG APPROVED BY ByDEPT. DATE SHEET SEQUENCE Na. <br /> GO w <br /> o CHECKED <br /> ete Lin�amen APPROVED BUILDING 45-205 JOB N0. COMP N0. <br /> APPROVED ARCHITECTURAL MASTER EVERETT, WA. DWG NO. 45-205-GO <br />