D. <br /> J� JUNCTION BOX 4S UNLESS NOTED OTHERWISE <br /> OS IONIZATION SMOKE DETECTOR <br /> HEAT DETECTOR FIXED 135° <br /> ❑F MANUAL STATION, DOUBLE ACTING <br /> ® STROBE ALARM <br /> ®Q AUDIBLE/VISUAL ALARM <br /> FIRE ALARM PANEL <br /> 5 4 3 2 1 ADT PANEL <br /> FAC CELLULAR COMMUNICATOR <br /> GENERAL NOTES <br /> 45-297 IS MONITORED BY 45-205 BUILDING FAC. <br /> BUILDING FA P <br /> — — I <br /> REFERENCE DRWAWINGS <br /> OM <br /> HEA WOMEN RESTROMAN PULL R N1 �— — — <br /> 1 45-205-1E60 POWER AND FIRE ALARM PLAN <br /> os, u:os ZONE #: 07, u:o7 2 2 1/2"C 2#14 vlEw <br /> 4 F 3 S <br /> 15CD _ _ _ _ SOK FA 45-205—E506 FIRE ALARM DETAILS <br /> LT!!!rr 6 /� 1/2„C 2#14— ZONE #: 01, 11:01 <br /> A CONSTRUCTION NOTES <br /> 71/2"C 2#14 SMK OFFICE W 30CD THIS FIRE ALARM DESIGN IS INTENDED TO BE A <br /> SMK OFFICE CENTER SMK OFFICE E PRELIMINARY DESIGN TO DIRECT A NICET CERTIFIED <br /> ZONE #: 02, L1:02 6 ZONE #: 03, L1:03 ZONE #: 04, L1:04 DESIGNER TO COMPLETE FINAL FIRE ALARM DESIGN IN <br /> HEAT MEN RE TROOM Q ®O 4 S 75CD ACCORDANCE WITH ALL APPLICABLE LAWS AND CODES. <br /> ZONE #: 06, L1:06 //�\ — — — — — — — — — APPLICATION FOR FIRE ALARM PERMIT USING FINAL <br /> 4 STAMPED DRAWINGS IS REQUIRED. <br /> 1/2"C 2#14 6 <br /> 4 REMOVE OLD FACP, FOCUS PANEL, AND ASSOCIATED <br /> 15CD HARDWARE. PROVIDE AND INSTALL NEW DIGITAL <br /> 6 ADDRESSABLE BUILDING FACP. PROVIDE PHENOLIC LABEL <br /> MAN PULII Si MAN PULL I3R S2 ON PANEL THAT READS: <br /> ZONE #: 08, -1:08 ZONE #: 09, L1:09 "45-205 FIRE ALARM CONTROL PANEL <br /> 4 F 4 F <br /> EVT—FA-45-205 <br /> 120 <br /> 120VAC FED FROM PANEL 'B'/11c” <br /> PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDIN <br /> FACP. SEE SHEET E506 FOR INSTALLATION DETAILS. <br /> INSTALL NEW SMOKE DETECTOR ABOVE FACP. <br /> ®REPLACE EXISTING FIRE ALARM DEVICE WITH NEW <br /> COMPATIBLE DEVICE. REUSE CONDUIT AND WIRE WHERE <br /> POSSIBLE. (TYP. 5 SMOKES, 3 MANUAL PULL STATIONS) <br /> FILL OUT AND RETURN ATTACHED BUILDING FACP <br /> POINTLIST TO ENGINEER A MINIMUM OF 3 WEEKS PRIOR <br /> TO FINAL ACCEPTANCE TESTING. <br /> ©PROVIDE NEW HORN/STROBE. NICET DESIGNER TO <br /> DETERMINE FINAL LOCATION AND QUANTITY AS REQUIRED <br /> BY CODE. <br /> SEE DRAWING 45-297-1E60 FOR 2 ADDITIONAL FIRE <br /> 1ST FLOOR FIRE ALARM PLAN ALARM POINTS. <br /> SCALE: 1/4"=1'—O" <br /> J <br /> l / 4' 2' 0 2' 4' 8' <br /> SCALE: 1/4" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEACCEPTAB-TY DRAWN AIL SUBTITLE CURRENT REVISION SYMBOL DATE N <br /> HIS DESIGN AND/OR CHECKED 1ST FLOOR FIRE ALARM PLAN 27851053 A 04.28.23 <br /> NEW FIRE PANEL REPLACEMENT 27851053 CSL MDK 08.19.22 SPECIFICATION IS APPROVED F- <br /> A "C SHEET 1 E260 <br /> A SHOP DRAWINGS AGOW�JS 04.28.23 m APPROVED BY DEPT. DATE <br /> CHECKED LL <br /> ete Linamen [ JOB N0. COMP NO. 'o <br /> APPROVED BUILDING �' 5 <br /> „mwma, 45-205-1E260 <br /> 11 APPROVED ELECTRICAL MASTER A/P STALL 103 EVERETT, WADwc No. 45-205-1E260 <br />