Laserfiche WebLink
BOEING COMMERCIAL AIRPLANE GROUP <br /> EVERETT FIRE PANEL REPLACEMENT <br /> BUILDING 45-213 <br /> BOEING EVERETT FACILITY <br /> 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 <br /> MICINITY MAP LOCATION MAP SITE PLAN INDEX OR DRAWINGS <br /> GENERAL <br /> • 45-213-GO GO COVER SHEET - 04.28.23 <br /> BOEING EVERETT FACILITY ELEGTR�GAL <br /> • 45-213-LOA EOA ELECTRICAL LEGEND & ABBREVIATIONS A 04.28.23 <br /> • 45-213-E260 E260 BUILDING 213 FIRE ALARM SYSTEM PLAN A 04.28.23 <br /> PROJECT <br /> LOCATION • 45-274-E60 E60 BUILDING 274 FIRE ALARM SYSTEM PLAN A 04.28.23 <br /> MREFf • 45-213-E506 E506 FIRE ALARM SYSTEM DETAILS A 04.28.23 <br /> U F- F- 45-6 <br /> 4,F 5 <br /> 45-52 <br /> 101 <br /> 45-6 <br /> 45-0345-04 <br /> EXISTING MAJOR 102 <br /> C+ BOEING FACIUDES <br /> P O D ,103 45-997 1 <br /> Cl Y I� <br /> 45-999 N <br /> 119 <br /> ELLEVUE 0 9� 104 45-99> 45-06 <br /> 118 45-02 <br /> 105 <br /> mE 90 c� Q ISI n <br /> I <br /> RENTON _ 1e0 <br /> N 6 i ()�f mEn sm <br /> KENT N7 n _ q a <br /> g LJ g o o- n� 19e POND <br /> UBDRN LLLIIII o_s6 o g <br /> 0 5 m 201 °as-sa <br /> MIL -° - 202 <br /> TACOMA 40_� <br /> Y °� � � <br /> PDGF EER DESCRIPTION OR WORK <br /> I <br /> r �"' THE SCOPE OF THIS PROJECT IS TO UPGRADE THE EXISTING BUILDING FIRE ALARM SYSTEM. <br /> 7 <br /> — *NOTE BUILDING 213 FACP PROVIDES DETECTION FOR BUILDINGS 211 & 274. <br /> F1 <br /> THE WORK TO BE PERFORMED INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: <br /> 1. REMOVE OLD FOCUS PANEL, AND ASSOCIATED HARDWARE. PROVIDE AND INSTALL NEW DIGITAL <br /> �fR ADDRESSABLE BUILDING FACE. <br /> oPop 2. PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDING FACE. SEE SHEET E506 FOR <br /> FfINE FIELD <br /> a� �� H INSTALLATION DETAILS. <br /> o 3. INSTALL NEW SMOKE DETECTOR ABOVE FACE. <br /> — <br /> _ 4. REPLACE EXISTING FIRE ALARM DEVICES WITH NEW COMPATIBLE DEVICES IN BUILDING 203. SEE <br /> 5 SN0H0M� 111� CDU�X - SHEET 1E260 FOR INSTALLATION DETAILS. <br /> Li 5-70 5. REPLACE EXISTING FIRE ALARM DEVICES WITH NEW COMPATIBLE DEVICES IN BUILDING 274. SEE <br /> SHEET 1E60 FOR INSTALLATION DETAILS. <br /> o RPS PROJECT SITE (I[[11gIiIII[III➢ 6. PROVIDE AND INSTALL NEW HORN/STROBE. <br /> 111 <br /> �M <br /> PROJECT TEAM <br /> 3 OWNER: BOEING EVERETT FACILITY ELECTRICAL: BOEING EVERETT FACILITY <br /> N N N 3003 WEST CASINO ROAD 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 EVERETT, WASHINGTON 98203 <br /> PROJECT MANAGER: RAY RIMORIN PROJECT MANAGER: LARRY HILL <br /> TEL: 425.330.1807 TEL: 425.328.5309 <br /> mDRAWN A SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY <br /> 3 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE N <br /> THIS DESIGN AND/OR CHECKED COVER SHEET A 04.28.23 0 <br /> NEW FIRE MONITORING PANEL REPLACEMENT 27851053 VIED TT 07.22.22 By SHEET SEQUENCE Na. a <br /> Y m PEaTIDIs APPROVED N IN TITLE EVERETTFIRE PANEL REPLACEMENT � <br /> 0 A SHOP DRAWINGS AGGW/J$ 04.28.23 BOE//VG APPROVED BY DEPT. DATE v <br /> w <br /> o CHECKED G <br /> ete Lin�amen APPROVED BUILDING 45-213 JOB NO. COMP NO. <br /> APPROVED ARCHITECTURAL MASTER EVERETT, WA. DWG NO. 45-213-GO <br />