My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-242 2023-11-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-242
>
3003 W CASINO RD BLDG 45-242 2023-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 11:13:35 AM
Creation date
11/22/2023 6:59:29 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-242
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FACP BATTERY CALCULATIONS PEM POWER CABLE (SUPPLIED <br /> STANDBY ALARM <br /> COMPONENTS QTY. ©5 WITH PEM) <br /> CURRENT CURRENT <br /> AFC-100(FACP) 1 0.13000A 0.22000A <br /> UD-2000(DACT) 1 0.01600A 0.02300A <br /> SLC DEVICES SUPERVISORY ALARM <br /> CURRENT CURRENT <br /> PAD-PD 4 CL00030A 0.00030A 0.00120A 0.00120A <br /> PAD-HD 2 0.00030A 0.00030A 0.00060A 0.00060A <br /> PAD-DUCT 0 0.00030A 0.00030A 0.000OOA O.o000OA <br /> PAD100-PSSA/PSDA z O.00020A 0.00020A 0.00060A 0.00060A 3 3/4"C - 2#14THHN,1#14G 'Z 0 <br /> PAD100-RM 0 O.00o24A 0.00024A 0.000OOA O.000OOA TG-PEM RED <br /> PAD100-MIM 2 0.00020A 0.00040A 0.00040A 0.00080A 1 <br /> PAD100-DIM 0 0.00024A 0.00024A o.000OOA o.000OOA FACP EVF-FA-45-242 I TG 7 ES <br /> STANDBY CURRENT cURRRRNT (BY FIRE ALARM VENDOR) DON 1 1 4 7 <br /> NAC CKT 1(AUX PWR) 0.018A 0.11000A 0.01800A 0.11 OOOA <br /> NAC CKT 2 O.00A 0.26200A 0.000OOA 0.26200A R <br /> OLOOA 0.000OOA o.000OOA o.00000A 3 <br /> SLC ALARM LED O.00A 0,036 OA 11.00000A 0.03600A T <br /> TOTAL 0.16700A 0.65420A <br /> TOTAL STANDBY CURRENT DRAW- 0.167 AMPS DG STC2 STCI TRIP BATT AG <br /> X STANDBY TIME 48 HOURS 1 2 1 2 3 4 5 6 1 2 3 1 2 G <br /> STANDBY AMP HOUR TOTAL- 8.016 AH 0� 00� 0� <br /> TOTAL ALARM CURRENT DRAW- 0.654 AMPS <br /> X ALARM TIME 0.167 HOURS <br /> RED EDL(AS NEEDED) <br /> ALARM AMP HOUR TOTAL= 0.110 AH <br /> STANDBY AH + ALARM AH = 8.13 AH <br /> X DE-RATING FACTOR 1.20(207) <br /> TOTAL AH REQUIRED= 9.75 AH <br /> MINIMUM BATTERY SIZE NEEDED: 10 AH 3/4"C - (1) PHONE CABLE, <br /> BATTERY SIZE PROVIDED: 12 AH (1) 2 CONDUCTOR FPL OR REFERENCE DRAWINGS <br /> NOTE: 0.167 EQUALS 10 MINUTES OF ALARM TIME <br /> APPROVED EQUAL <br /> 45-242-E260 FIRE ALARM PLAN VIEW <br /> FACP VOLTAGE DROP CALCULATION <br /> CIRCUIT SUPPLY ALARM OHMS NGT TOTAL LAST DEVICE ;DROP <br /> LTAG C v //�� CONSTRUCTION NOTES <br /> NAME VOLTAGE CURRENT WIRE TYPE 3.00 F FEET RESISTANCE VOLTAGE % IRE ALARM S STEM COMMUNICATIONS D ETAI E <br /> NAct(Aux) 20.4 voc 0.110 A g14Awc soup 3.07 to 0.0614 20.393 voc 0.03% � PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> NAC2 20.4 voc 0.262 A #14AWG SOLID 3.07 118 0.7245 20.21 VDC 0.93% SCALE: NONE E260 E566 THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> N/A 20.4 VDC 0.000 A #14Awc SOLID 3.07 0 0 00.00 voc 0% SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> COMPATIBLE WITH AT&T CELL SERVICE. <br /> N/A 20.4 VDC 0.000 A #14AWG SOLID 3.07 0 0 00.00 VDC 0% <br /> STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> o� ooh DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> COGFS Q TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. BUILDING FACP. <br /> �A� QS QS �� ya� �FFG� �FFG� �FFG� COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. <br /> �WF <br /> jvs <br /> * POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> MONITORED BY YCO ANDSTEP 3: IF ACCEPTABLE SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> F F S S S S CELLULAR CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE MODULE AND WIRE AS SHOWN. MAINTAIN <br /> :09 08 1:07 L1:06 L1:05 L1:04 L1:03 L1:02 L1:01 ANAL G PHON LINE DIALER SIGNAL SENT TO CENTRAL WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. MANUFACTURER'S REQUIRED 1 4 SEPARATION <br /> LRIMARY� TG-7FS-A BOEING FIRE DEPARTMENT /STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE BETWEEN POWER AND COMMUNICATION WIRING. <br /> 45-242 FACP *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE, AS SHOWN. FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED PROVIDE PHENOLIC 15CD 30CD 30CD NAC2 WITHIN 20FT OF EACH OTHER. BACKGROUND, THAT RADS:WHITE LETTERING, RED <br /> STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM <br /> ANALOG PHONE LINE BUILDING FACP. "FIRE ALARM CELLULAR DIALER" <br /> (SECONDARY) STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER [5:�, PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> EVT-FA-45-242 THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> SOLE PATH FOR FIRE COMMUNICATIONS. CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> IS NOT SUITABLE AT FACP LOCATION. UPDATE BOM <br /> LXS2V27-242/7b" *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> ORDINANCES. TO BOEING ENGINEER. <br /> © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> BUILDING C IRE A LAR M SYSTEM B S E R WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> SCALE: NONE E506 CELLULAR COMMUNICATOR INSTALLATION SEQUENCE "FIRE ALARM CELLULAR ANTENNA" <br /> SCALE: NONE E260 E506 7� INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> q SETTINGS AND CELLUAR PHONE NUMBER. PROVIDE45-242 BUILDING SYSTEM FACP POINTS PRINTED LABEL, HANDWRITTEN INFORMATION IS NOT <br /> ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. INFORMATION TO BOEING ENGINEER. <br /> L1:001 1 SMK @ FACP FACP SMOKE DETECTOR - A3/E260 <br /> _1:002 2 SMK OFFICE NORTH OFFICE NORTH SMOKE DETECTOR - A2/E260 <br /> L1:003 3 SMK OFFICE CENTER OFFICE CENTER SMOKE DETECTOR - A3/E260 <br /> _1:004 4 SMK OFFICE SOUTH OFFICE SOUTH SMOKE DETECTOR - A4/E260 BILL �F MATERIALS <br /> ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> L1:005 HEAT WOMENS RESTROOM WOMENS R.R. HEAT DETECTOR - B1/E260 <br /> 5 <br /> _1:006 5 HEAT MENS RESTROOM MENS R.R. HEAT DETECTOR - Al/E260 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> _1:007 7 MAN PULL DR E1 N.E. EXIT MANUAL PULL - B1/E260 2 1 3992769 POTTER UD-2000 DACT CARD <br /> L1:008 8 MAN PULL DR E2 EAST EXIT MANUAL PULL - B3/E260 3 6 3992732 POTTER PAD100 6" BASE <br /> L1:009 9 SV45-47 HI LO AIR SPRINKLER HI/Low AIR SWITCH - 35/E260 4 4 3992770 POTTER PAD200 PHOTO DETECTOR <br /> L1:010 10 SV45-47 WE SPRINKLER WE PRESSURE SWITCH - B5/E260 5 2 3992735 POTTER PAD100 HEAT DETECTOR(1350 FIXED) <br /> 6 1 2 3992720 POTTER PAD100 PULL STATION <br /> 7 2 3992700 POTTER PAD100-MIM <br /> BUILDING FACP POINTS LIST 8 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> 9 2 BK-PC2RL SYSTEM SENSOR HORN/STROBES <br /> SCALE: NONE El06 10 2 BK-SCRL SYSTEM SENSOR STROBES <br /> 11 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> 12 1 SSU0068 TELGUARD FIRE ALARM STORAGE CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL BATE <br /> HIS DESIGN AND/ CHECKED FIRE ALARM SYSTEM DETAILS 27851053 A 04.28.23 0 <br /> NEW FIRE MONITORING PANEL REPLACEMENT 27851053 MDK TT 09.20.22 o <br /> SPECIFICATION IS APPROVED SHEET <br /> A SHOP DRAWINGS AGOW/JS 04.28.23BOE//VG® <br /> APPROVED BY DEPT. DATE TITLE E506 <br /> CHECKED <br /> e <br /> Lin e BUILDING 45-242 JOB NG DMP NG. <br /> .mE.amm�wmn=„tea APPROVED <br /> APPROVED ELECTRICAL MASTER EVERETT, WA DWG NO. 45-242-E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.