Laserfiche WebLink
AIF <br /> Permit#: FA2305-024 r , <br /> Site Address: 1402 SE Everett Mall Way <br /> EVERETT ApplicantFireless Fii ie lnc. FIRE PROTECTION INC. <br /> V Application Date:05/26/2023 17410 Ash Way,Ste 8 <br /> CENTRAL STATION REPORTING ZONES Description: Wireless Fire AlarmCommunirator Lynnwood,WA 98037 <br /> 425-290-9600 <br /> ZONE # ZONE DESCRIPTION Review Status: 1st Review by City BPeer Reviewers FPISEATTLE.COM <br /> Review Date: 06/05/2023 <br /> 1 GENERAL ALARM <br /> 3 SUPERVISORY <br /> ` TW iw EAES RADO NSTALLATCN EverettDept.Per Re [47v, <br /> Status:Approved <br /> Reviewed <br /> CONTACT ID AES-FA05 06/05/2023i1o8:59� <br /> EVERETT , WA AM NEPA®000805173 <br /> ROY L CATS <br /> OPERATIONAL MATRIX AES INSTALLATION DETAIL SHEET INDEX QPOTECT70y <br /> # C Nn <br /> SHEET SHEET DESCRIPTION �+ ^r <br /> Y ^' <br /> FA 0.0 FIRE ALARM NFPA AES INSTALLATION b <br /> `�J Y <br /> SYSTEM OUTPUTS CFPS <br /> Required Fire Sadety Control PROJECT DETAILS <br /> #1473 <br /> Central Supervising Station roe <br /> 1. THE EXISTING BUILDING IS FULLY-SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ALARM CONTROL <br /> Control Unit Annunciation ,� ® O ° PANEL(FARENHYT SERIES IFP-2000) LOCATED IN THE BUILDINGS RISER ROOM. <br /> °C r <br /> O O O O ° Co 2. A NEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88-ULP) IS BEING INSTALLED, SIGNALS WILL BE e <br /> C y o m� TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah BATTERY WILL BE #n <br /> m c°j m`y m ® INSTALLED IN THE NEW AES RADIO. e# a <br /> y <br /> WIRE TO BEI 3. THE FOLLOWING SIGNALS SHALL BE TRANSMITTED TO THE CENTRAL SUPERVISING STATION : ZONE 1: v Z w <br /> yC yJ¢_�� CONDUIT _ OO OO OO GENERAL ALARM, ZONE 2: SUPERVISORY, ZONE 3:TROUBLE. F N w <br /> °m Qo 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. <br /> wN <br /> cm o� � ` c°o� ° `� 0 000000 o x CONTACT INFO o v x <br /> cm Q aQ m° .01. <br /> i rc <br /> PROPERTY OWNER FIRE ALARM CONTRACTOR a <br /> �49 BRIXTON EVERETT, LLC FIRE PROTECTION INC u o'. <br /> e? <br /> o <br /> -10 Q 2 �° o ❑ C/O JONES LANG LASALLE 17410 ASH WAY, Ste 8 z m 219 C <br /> �8 P.O. BOX 82618 LYNNWOOD, WA 98037 o u F o <br /> GOLETTA, CA 93118 CONTACT : DAVID MOW M 3 rc f <br /> 0 o CONTACT : AJ WOOLSEY PHONE 425.290.9600 ;w o <br /> BATTERY PHONE x a 425.231.0799 o rc w a o <br /> 12VDC 12ANP <br /> CODE INFORMATION REVISION RECORD <br /> SYSTEM INPUTS A BIC D E I F G H I <br /> 1 Manual Fire Alarm Pull-Station X X X X 1 DATE/DESCRIPTION <br /> 2 Smoke Detectors X X X X 2 AES-7707 RADIO CO1VIVIJNICATOR AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> 4 3 Unused X X X X 3 <br /> 4 Unused X X X X X 4 BUILDING USE AND OCCUPANCY B - FULLY SPRINKLED <br /> a 5 Duct Detectors X X 5 STANDARDS: 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> 11 1) 6 Unused X X 6 CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> 7 Fire Alarm AC Power Failure X X 7 REMOTE SUPERVISING STATION : STANLEY SECURITY, INC. <br /> M 8 Fire Alarm System Low Battery X X 8 PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION, INC. <br /> H 9 Open Circuit XX 9 PARCEL NUMBERS : 28051800401800 <br /> 10 Ground Fault X X 10 <br /> A B C D E F G H I INSTALLATION NOTES <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> VICINITY MAP 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> EXISTING FARE HYTSERIESIFP-2000 FIRE ALARMCONIItOLPAi�L DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). <br /> 5. THE SYSTEM WILL BE 1009 PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND <br /> PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> INSPECTION. DATE: 05/25/2023 <br /> 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL PROJECT NAME <br /> DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT <br /> c (NFPA72, SECTION 10.5.5.2). <br /> / Q <br /> BOULEVARD uL ow LL DEVICE INSTALLATION REQUIREMENTS J 00 <br /> J fV <br /> _ \ TIRE ALARM DEVICE INSTALLATION REQUIREMENTS a a CO <br /> NOT PERMITTED d a <br /> BSUPPORT RACKET DIFFUSER HERE 4" Lu <br /> T ACT W <br /> -eox <br /> RIVERCRESTi GRID II LIJW LL W <br /> V LL W <br /> -+-"/ 1. FA DEVICE CEILING W Z_ LUQ' <br /> 1402 SE Everett Mall SMOKE > LU <br /> 1 f I t DETECTOR 4•• W Q W W <br /> Way,Everett,WA 98201 MINIMUM 3' > <br /> r-EaStrT10DS I - AWAY FROM NOT PERMITTED t2.• CN ll.l <br /> -1 EVERETT MALL H S HVAC DIFFUSERS "ERE SMOKE <br /> 1 <br /> 96 SFIVBr f FACP ROOM <br /> Fres I <br /> OUTDOOR _ <br /> HORN/STROBE MAX HEIGHT 92"A.F.F <br /> MIN HEIGHT 82"A.FE SHEET TITLE <br /> Jorth 'EFF <br /> nwood Mill --JL FAA <br /> •�Creek. j - - FIRE ALARM <br /> d MilCreE!I( I' ® O° _ PROJECT DETAILS <br /> N A F.F 60"A.F.F PULL <br /> 48"AF.F <br /> Not to Scale <br /> SHEET NUMBER <br /> NI " L FA 0.0 <br />