My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1402 SE EVERETT MALL WAY BASE FILE 2023-11-29
>
Address Records
>
SE EVERETT MALL WAY
>
1402
>
BASE FILE
>
1402 SE EVERETT MALL WAY BASE FILE 2023-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 8:45:25 AM
Creation date
11/22/2023 7:13:27 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1402
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications Approved Releasing Solenoids <br /> Physical Manufacturer Part number Rating Current Freq <br /> Flush Mount Dim: 14.75"W x 25"H x 4"D Asco T8210A107 24 VDC 3 A max 0 Hz <br /> (37.5 W x 63.5 H x 10.16 D cm) Asco 8210G207 24 VDC 3 A max 0 Hz <br /> Overall Dimensions:1 6"W x 26.4"H x 4.65"D Ordering Information <br /> (40.6 W x 67 H x 11.8 D cm) <br /> IFP-2000 Intelligent Fire Alarm Control Panel <br /> Weight: 28 lbs. (12.8 kg) IFP-2000HV High Voltage (240VAC) Intelligent Fire <br /> Color: Red Alarm Control Panel <br /> RPS-2000 Intelligent Fire Alarm Control Panel <br /> Environmental without built in display <br /> Operating Temperature: 32°Fā 120°F (0°Cā49°C) RPS-2000HV High Voltage (240VAC) Intelligent Fire <br /> Humidity: 10%ā93% non-condensing d Is rP a display Panel without built-in <br /> Electrical SBUS Accessories <br /> IFP-2000 AC: 120 VAC, 50/60 Hz, S.OA RA-2000 Red Remote Annunciator. Four line LCD <br /> annunciator with 40 characters per line <br /> IFP-2000HV AC: 240 VAC, 50/60 Hz, 2.5A RA-2000GRAY Gray Remote Annunciator Four line LCD <br /> Total Accessory Load: 9A @ 24 VDC power-limited annunciator with 40 characters per line <br /> Standby Current: 290 mA 5815XL Signal Line Circuit (SLC) Expander <br /> Alarm Current: 530 mA RPS-1000 6 amp Intelligent Power Module with 6 <br /> flexputs <br /> Battery Charging Capacity: 17 to 55 AH 5496 6 amp intelligent Power Module <br /> Battery Size: 18 AH max. allowed in control panel cabinet. 5824 Serial/Parallel Printer Interface Module <br /> Larger capacity batteries can be housed in RBB or AB-55 5880 LED 1/0 Module <br /> accessory cabinet. 5865-3 &5865-4 LED Fire Annunciators <br /> 5883 Relay Interface Board <br /> Flexput Circuits IDP Devices <br /> Eight circuits that can be programmed individually as: <br /> Notification Circuits: 3A per circuit @ 24 VDC, power-limited See the spe IDP devices <br /> ecification sheets listed below for a complete <br /> Auxiliary Power Circuits: 3A per circuit @ 24 VDC, power- <br /> listing of th <br /> limited 350361 Intelligent Device Protocol devices <br /> specification sheet <br /> Initiation Circuit: 100 mA per circuit @ 24 VDC, power-limited Hochiki Devices <br /> See the specification sheets listed below for a complete <br /> Indicator Lights listing of the Hochiki devices <br /> General Alarm (Red): On when in alarm 350360 Hochiki (SD) Device Protocol devices <br /> Supervisory(Yellow): On when a supervisory condition exists specification sheet <br /> System Troubles (Yellow): On when a trouble condition exists Networking Accessories <br /> IFP-RPT-FO Network repeater board for fiber optic <br /> System Silenced (Yellow): On when an alarm, trouble or IFP-RPT-UTP Network repeater board for twisted pair <br /> supervisory condition has been silenced but not yet cleared wire <br /> System Power(Green): Off for AC failure; On when power IFP-RPT-UTP-KIT Wired twisted pair network repeater card <br /> systems are normal and cabinet kit. <br /> IFP-RPT-FO-KIT Fiber optic network repeater card and <br /> Telephone cabinet kit. <br /> Requirements: FCC Part 15 & Part 68 approved Miscellaneous Accessories <br /> Jack: RJ31X(two required) 5655 Silent Knight Software Suite -2. <br /> Provides programming, upload <br /> Approvals /download, and event reporting <br /> NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central RBB Remote Battery Box Accessory Cabinet. <br /> Station; Remote Signalling; Local Protective Signalling Use for backup batteries up to 35 AH. <br /> Dimensions: 16"W x 10" H x 6" D <br /> Systems;Auxiliary Protected Premises Unit; &Water Deluge (40.64 W x 25.4 H x 15.24 D cm) <br /> Releasing Service. Suitable for automatic, manual, waterflow, AB-55 Remote Battery Box Accessory Cabinet. <br /> sprinkler supervisory(DACT non-coded)signalling services Use for backup batteries that are <br /> Other Approvals: UL Listed, FM Approved, City of New York, 35 AH -55AH. <br /> and CSFM Dimensions: 20"W x 12" H x 7.5" D <br /> (50.8 W x 30.48 H x 19.05 D cm) <br /> SILENT This document is not intended to be used for installation purposes.We try to keep <br /> our product information up-to-date and accurate.We cannot cover all specific <br /> KNIGHT applications or anticipate all requirements.All specifications are subject to change <br /> without notice. For more information, contact Silent Knight 12 Clintonville Road, <br /> Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. <br /> by Honeywell www.farenhyt.com Made in the U.S.A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.