• GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION,LOAD CENTER,AND/OR AMBIENT TEMPERATURE SPECIFICATIONS SOLAR MODULE SPECIFICATIONS <br /> DISCONNECTS.DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ <br /> (AUTHORITY HAVING JURISDICTION).PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CONDUCTOR CONDUCTOR TEMPERATURE <br /> RECORD AMBIENT TEMP VMP IMP VOC ISC #OF <br /> • WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN LOW TEMP (HIGH TEMP 2%) RA EP(ON ROOF) RATE(OFRF ROOF)ATURE MANUFACTURER/MODEL# (V) (A) (V) (A) COOF V CENT MODULES <br /> TO INVERTER. HYUNDAI SOLAR HIS-S400YH(BK) CAPST°NE <br /> • PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE 7° 29° 90° 75° (400W) 37.7 10.61 45.3 11.25 0.268%/K 25 S O L A R <br /> PROTECTED IN A CONDUIT,RACEWAY,OR ARMORED PROTECTIVE SHEATHING(NEC 250.64). <br /> • THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE SYSTEM SIZE:-25 x 40OW=10.000 kWDC MODULE DIMENSION 75.74"L x 40.86"W x 1.37"D P.O Box 715 <br /> NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 13 x 768VA=9.984 kWAC REDMOND,WA 98073 <br /> • ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC INVERTER SPECIFICATIONS Contractor License:CC CAPSTS18830S <br /> Electrical License:EC CAPSTS1868JD <br /> 300.6 C1,310.8 D). NOMINAL OUTPUT NOMINAL OUTPUT <br /> • ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. MANUFACTURER/MODEL# QUANTITY VOLTAGE CURRENT <br /> • ALL CONDUIT SHALL BE EMT OR PVC 3/4"IN DIAMETER UNLESS OTHERWISE STATED. <br /> SERVICE INFO. AP SYSTEMS DS3-L 13 240 VAC 3.20A <br /> NOTE: <br /> 3/4"OR GREATER EMT OR PVC UTILITY PROVIDER: SNOPUD <br /> CONDUIT RUN INSIDE ATTIC MAIN SERVICE VOLTAGE: 240V <br /> MAIN PANEL BRAND: SIEMENS <br /> NOTE:THE VISIBLE,LOCKABLE,LABELED AC DISCONNECT MAIN SERVICE PANEL: (E)200A <br /> IS LOCATED WITHIN 1OFT OF UTILITY METER <br /> MAIN CIRCUIT BREAKER RATING: (E)200A <br /> MAIN SERVICE LOCATION: EAST METER NO.-1000619945 <br /> SERVICE FEED SOURCE: OVERHEAD VERSION <br /> DESCRIPTION DATE REV <br /> INITIAL RELEASE 11/01/2023 UR <br /> 05 x AP SYSTEMS DS3-L MICRO-INVERTERS WITH 10 PV MODULES IN BRANCH CIRCUIT#1 <br /> ® ® O AC DISCONNECT SHALL BE LOCATED <br /> •• • <br /> WITHIN 10'OF UTILITY METER BI-DIRECTIONAL <br /> UTILITY METER <br /> 1-PHASE,3-W, <br /> ____ 120V/24OV,60Hz ANNUAL PRODUCTION <br /> ESTIMATE 5,686 kWh's <br /> 7T <br /> (05)AP SYSTEMS DS3-L MICRO-INVERTERS(240V) I <br /> 03 x AP SYSTEMS DS3-L MICRO-INVERTERS WITH 06 PV MODULES IN BRANCH CIRCUIT#2 (N)125A SOLAR LOAD <br /> CENTER q <br /> (N)JUNCTION BOX <br /> ET <br /> I <br /> s s I <br /> -------------- 20AI2P <br /> (N) 60A FUSED VISIBLE, <br /> LINE SIDE TAP PROJECT NAME <br /> WL <br /> am $Mae <br /> L2 L LOCKABLE,LABELED AC <br /> (03)AP SYSTEMS DS3-L MICRO-INVERTERS(240V) I DISCONNECT,WITH 60A <br /> 03 x AP SYSTEMS DS3-L MICRO-INVERTERS WITH 06 PV MODULES IN BRANCH CIRCUIT#3 I L1 L1 <br /> 20A/2P FUSES,240 VAC <br /> I ( SERVICE PANEL, <br /> I L2 L 200A - <br /> qP 20AI2P 120/2 RATED,L1 60A FUSES 120/24oV wI 20A/2P L1 L1 w (r) OL2 L IF - L2 L2 (E)MAIN BREAKER QO <br /> — Lij <br /> -------- ------------- ---------------i 200A/2P,240V LwN/ <br /> (03)AP SYSTEMS DS3-L MICRO-INVERTERS(240V) L1 7 N N L 1_ OD O O <br /> 02 x AP SYSTEMS DS3-L MICRO-INVERTERS WITH 03 PV MODULES IN BRANCH CIRCUIT#4 I L2 L [" LL <br /> 88 — — — — Q O7 00 z W <br /> —��— f— -- J G > m Lf') W <br /> r- -- w O rn O <br /> -------------- -------------------------------- A B C 0 co O <br /> O (=) _Lr) Ujj U <br /> (02)AP SYSTEMS DS3-L MICRO-INVERTERS(240V) EXISTING � <br /> J Uj 0- <br /> � <br /> TERMINATOR CAP ON LAST CABLE GROUNDING w <br /> CONNECTOR AC TRUNK CABLE(TYP) - SYSTEM w Q Q <br /> Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire <br /> Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type <br /> A OPEN AIR 4 12 AWG TRUNK CABLE 90°C 30 1.0 N/A 30.00 05 3.20 1.25 20.00 06 AWG BARE CU <br /> SHEET NAME <br /> B 3/4" EMT g 10 AWG THWN-2 90°C 40 1.0 0.70 28.00 05 3.20 1.25 20.00 10 AWG THWN-2 ELECTRICAL LINE <br /> OR PVC DIAGRAM & <br /> C 3/4" EMT 3 6 AWG THWN 75°C 65 1.0 1.0 65.00 13 3.20 1.25 52.00 10 AWG THWN CALCULATION <br /> OR PVC SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> 1 ELECTRICAL LINE DIAGRAM WITH CALCULATION PV-4 <br /> SCALE: NTS <br />