My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4729 VIEW DR 2023-12-08
>
Address Records
>
VIEW DR
>
4729
>
4729 VIEW DR 2023-12-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2023 2:54:18 PM
Creation date
11/28/2023 7:03:05 AM
Metadata
Fields
Template:
Address Document
Street Name
VIEW DR
Street Number
4729
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l <br /> Robert and Lisa Flake JN 16005 <br /> January 27, 2016 Page 3 <br /> SEISMIC CONSIDERATIONS <br /> In accordance with the International Building Code (IBC), the site soil profile within 100 feet of the ground <br /> surface is best represented by Soil Profile Type D (Stiff Soil). As required by the SBC, the design criteria <br /> presented in this report consider the effects of a one-in-100-years seismic event for slope stability. <br /> The site soils in the area of the proposed structures are not susceptible to seismic liquefaction because of their <br /> dense nature. This statement regarding liquefaction includes the knowledge of the determined peak ground <br /> acceleration noted above. <br /> CONVENTIONAL FOUNDATIONS <br /> As discussed in the General section, special requirements are in order for the eastern foundations of the <br /> garage. The remaining proposed structure can be supported on conventional continuous and spread footings <br /> bearing on undisturbed, medium-dense to dense native soil, or on structural fill placed above this competent <br /> native soil. See the section entitled General Earthwork and Structural Fill for recommendations regarding <br /> the placement and compaction of structural fill beneath structures. Adequate compaction of structural fill should <br /> be verified with frequent density testing during fill placement. Prior to placing structural fill beneath foundations, <br /> the excavation should be observed by the geotechnical engineer to document that adequate bearing soils have <br /> been exposed. We recommend that continuous and individual spread footings have minimum widths of 16 and <br /> 24 inches, respectively. Footings should also be bottomed at least 18 inches below the lowest adjacent finish <br /> ground surface. The local building codes should be reviewed to determine if different footing widths or <br /> embedment depths are required. Footing subgrades must be cleaned of loose or disturbed soil prior to pouring <br /> concrete. Depending upon site and equipment constraints, this may require removing the disturbed soil by <br /> hand. <br /> An allowable bearing pressure of 3,000 pounds per square foot (psf) is appropriate for footings supported on <br /> competent native soil. A one-third increase in this design bearing pressure may be used when considering <br /> short-term wind or seismic loads. For the above design criteria, it is anticipated that the total post-construction <br /> settlement of footings founded on competent native soil will be less than one inch. <br /> Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and the bearing <br /> soil, or by passive earth pressure acting on the vertical, embedded portions of the foundation. For the latter <br /> condition, the foundation must be either poured directly against relatively level, undisturbed soil or be <br /> surrounded by level structural fill. We recommend using the following ultimate values for the foundation's <br /> resistance to lateral loading: <br /> Parameter ULTIMATE <br /> Value <br /> Coefficient of Friction 0.50 <br /> Passive Earth Pressure 350 pcf <br /> Where: (i)pcf is pounds per cubic foot,and(ii)passive <br /> earth pressure is computed using the equivalent fluid <br /> density. <br /> If the ground in front of a foundation is loose or sloping, the passive earth pressure given above will not be <br /> appropriate. We recommend maintaining a safety factor of at least 1.5 for the foundation's resistance to lateral <br /> loading, when using the above ultimate values. <br /> GEOTECH CONSULTANTS,INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.