Laserfiche WebLink
BOEING COMMERCIAL AIRPLANE GROUP <br /> EVERETT FIRE PANEL REPLACEMENT Permit#: FA2305-006 <br /> Site Address: 3003 W Casino Rd 45-201 <br /> Applicant: Alexander Gow <br /> Application Date:5/17/2023 <br /> Description: Replace Sprinkler Monitoring Panel <br /> BUILDING 45 201 Review Status 1st Review by City&Peer Reviewers <br /> Review Date: 5/17/2023 <br /> L <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 05/17/2023 12:03:00 <br /> PM <br /> BOEING EVERETT FACILITY <br /> 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 <br /> MICINITY MAP LOCATION MAP SITE PLAN INDEX OR DRAWINGS <br /> GENERAL <br /> • 45-201—GO GO COVER SHEET — 04.28.23 <br /> BOEING EVERETT FACILITY ELECTR�GAL <br /> • 45-201-LOA EOA ELECTRICAL LEGEND & ABBREVIATIONS A 04.28.23 <br /> • 45-201-E260 E260 BUILDING 201 FIRE ALARM SYSTEM PLAN A 04.28.23 <br /> PROJECT <br /> LOCATION • 45-276-E60 E60 BUILDING 276 FIRE ALARM SYSTEM PLAN A 04.28.23 <br /> MREFf • 45-201—E506 E506 FIRE ALARM SYSTEM DETAILS A 04.28.23 <br /> U F- F- 45-6 <br /> 4, 45-52 <br /> F 5 <br /> 101 <br /> 45-6 <br /> 45-0345-04 <br /> EXISTING MAJOR 102 <br /> G BOEING FACIUDES <br /> P O D ,103 45-997 1 <br /> Cl Y I� <br /> 45-999 <br /> 9 0 <br /> N 9� 104 45-99 45-06 <br /> ELLEVUE 118 45-02 <br /> los <br /> aE 90 c� Qn <br /> o eo <br /> RENTON <br /> N 6 i ()�f man sm <br /> ® J ..w� s 107 .1 6.e <br /> KKENT7 <br /> gAI IT o o- n� 10e POND <br /> UBURN M LLLIIII o_s6 o g <br /> 0 5 10 7 �- 1 °45-5e <br /> MILS p o <br /> p ss rM 202 <br /> — TACOMA 40_� <br /> Y PROJECT SITE <br /> PDGF E ER °� �` °s & & & DESCRIPTION OR WORK <br /> I <br /> THE SCOPE OF THIS PROJECT IS TO UPGRADE THE EXISTING BUILDING FIRE ALARM SYSTEM. <br /> *NOTE BUILDING 201 FACP PROVIDES DETECTION FOR BUILDINGS 201 & 276. <br /> FT <br /> THE WORK TO BE PERFORMED INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: <br /> a MTs i — <br /> 4 ® " 1. REMOVE OLD FOCUS PANEL, AND ASSOCIATED HARDWARE. PROVIDE AND INSTALL NEW DIGITAL <br /> �fR ADDRESSABLE BUILDING FACP. <br /> oPo.o 2. PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDING FACP. SEE SHEET F506 FOR <br /> INSTALLATION DETAILS. <br /> FrINE FIELD 3. INSTALL NEW SMOKF DETECTOR ABOVF FACP. <br /> PROJECT SITE j 4. REPLACE EXISTING FIRE ALARM DEVICES WITH NEW COMPATIBLE DEVICES IN BUILDING 201. SEE <br /> SNOHONI COU SHEET 1F260 FOR INSTALLATION DETAILS. <br /> 5 �A, <br /> � 5. REPLACE EXISTING FIRE ALARM DEVICES WITH NEW COMPATIBLE DEVICES IN BUILDING 276. SEE <br /> [III�IIIIIIII SHEET 1E60 FOR INSTALLATION DETAILS. <br /> 6. PROVIDE AND INSTALL NEW HORN/STROBE. <br /> wm <br /> PROJECT TEAM <br /> 3 OWNER: BOEING EVERETT FACILITY ELECTRICAL: BOEING EVERETT FACILITY <br /> \ N N N 3003 WEST CASINO ROAD 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 EVERETT, WASHINGTON 98203 <br /> PROJECT MANAGER: RAY RIMORIN PROJECT MANAGER: LARRY HILL <br /> TEL: 425.330.1807 TEL: 425.328.5309 <br /> m A SUBTITLE CURRENT REVISION SYMBOL GATE <br /> 3 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY N <br /> THIS DESIGN AND/OR CHECKED COVER SHEET A 04.28.23 0 <br /> NEW FIRE MONITORING PANEL REPLACEMENT 27851053 MDK TT 07.22.22 SHEET SEQUENCE <br /> Y m PEaTIDBy Is DEPRovED N IN TITLE EVERET FIRE PANEL REPLACEMENT G� <br /> 0 A SHOP DRAWINGS AGOW/J$ 04.28.23 BOE//VG APPROVED BY DEPT. DATE v <br /> w <br /> o CHECKED <br /> ete Lin�amen APPROVED BUILDING 45-201 JOB NO. COMP NO. <br /> APPROVED ARCHITECTURAL MASTER EVERETT, WA. DWG NO. 45-201-GO <br />