My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-211 2023-11-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-211
>
3003 W CASINO RD BLDG 45-211 2023-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:31:56 PM
Creation date
11/29/2023 1:28:03 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-211
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FACP BATTERY CALCULATIONS <br /> COMPONENTS orv. CUBRENT CURRENT REM POWER CABLE (SUPPLIED <br /> AFC-100(FACP) 1 0.13000A 0.22000A WITH PEM <br /> UD-2000(DACT) 1 0.01600A 0.02300A 6 5 3 4 <br /> SLC DEVICES SUPERVISORY ALARM <br /> CURRENT CURRENT <br /> PAD-PD 6 0.00030A 0.00030A 0.00180A 0.00180A 1 <br /> PAD-HD 2 0.00030A 0.00030A 0.00060A 0.00060A <br /> PAD-DUCT 0 0.00030A 0.00030A 0.000OOA O.Oo000A <br /> PAD100-PSSA/PSDA 3 O.00020A 0.00020A 0.00060A 0.00060A <br /> PAD100-RM 0 0.00024A 0.00024A O.000OOA O.000OOA <br /> PAD-MIM 00.00020A 0.00040A o.000OOA O.000OOA L3/4"C - 2#14THHN,1#14G Z B <br /> PAD100-DIM 0 0.00024A 0.00024A O.000OOA O.o0000A TG-PEM STANDBY ALARM <br /> CURRENT CURRENT �K <br /> NAC CKT 1(AUXPWR) o.018A 0.11000A 0.01800A 0.11007A FACP EVT-FA-45-211 TG-7ES <br /> NAC CKT 2 O.GOA 0.28100A O.000OOA 0.28100A <br /> o.00A o.00000A o.00000A 2! IA (BY FIRE ALARM VENDOR) GRN 1 4 7 <br /> SLC ALARM LED O.GOA 0.03600A O.000GOA <br /> 0.0360OA R <br /> TOTAL 1 0.15700A 0.67300A 3 <br /> TOTAL STANDBY CURRENT DRAW- 0.157 AMPS T <br /> X STANDBY TIME 48 HOURS <br /> STANDBY AMP HOUR TOTAL- 7.536 AH DG STC2 STGI TRIP BATT AG <br /> TOTAL ALARM CURRENT DRAW- 0.673 AMPS 1 2 1 2 3 4 5 6 1 2 3 1 2 G <br /> X ALARM TIME 0.167 HOURS �� �� BB <br /> ALARM AMP HOUR TOTAL= 0.112 AH <br /> STANDBY AH + ALARM AH = 7.65 AH RLK <br /> X DE-RATING FACTOR 1.20(207) RE0 EOL(q5 NEEDED) <br /> TOTAL AH REQUIRED= 9.1S AH <br /> MINIMUM BATTERY SIZE NEEDED: 10 AH <br /> BATTERY SIZE PROVIDED: 12 AH <br /> NOTE: 0.167 EQUALS 10 MINUTES OF ALARM TIME <br /> 3/4"C - (1) PHONE CABLE, <br /> (1) 2 CONDUCTOR FPL OR <br /> APPROVED EQUAL <br /> FACP VOLTAGE DROP CALCULATION CONSTRUCTION NOTES <br /> CIRCUIT SUPPLY ALARM OHMS NGT TOTAL LAST DEVICE VOLTAG <br /> NAME VOLTAGE CURRENT WIRE TYPE 000 F. EEET RESISTANCE VOLTAGE DROP% [j�::, PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> NAC1(AUX) 20.4 VDC 0.110 A #14AWG SOLID 3.07 10 0.0614 20.393 VDC 0.03% THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> NAC2 20.4 VDC 0.281 A #14AWG SOLID 3.07 103 0.6324 20.22 VDC 0.88% SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> N/A 20.4 VDC 0.000 A #14AWG SOLID 3.07 0 0 00.00 VDD 0% EIRE ALARM SYSTEM COMMUNICATIONS DETAIL COMPATIBLE WITH AT&T CELL SERVICE. <br /> N/A 20.4 VDC 0.000 A #14AWG SOLID 3.07 0 0 00.00 VDC 0% SCALE: NONE 7260 E506 <br /> PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> �� �o�S STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> � �F`4 0� 0 DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. BUILDING FACP. <br /> C31 <br /> �O� \GFS \GFS �Qd STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS 3� PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> QJ QJ �F QJ �F �F TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> F F S F S S S CELLULAR MONITORED BY YCO AND APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. MODULE AND WIRE AS SHOWN. MAINTAIN <br /> 1:09 _1:06 _1:05 1:08 _1:04 1:07 _1:02 _1:03 _1:01 ANALOG PHON LINE DIALER SIGNAL SENT TO CENTRAL STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> RIM A RI TG-7FS-A BOEING FIRE DEPARTMENT CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE BETWEEN POWER AND COMMUNICATION WIRING. <br /> 45-211 FACP <br /> TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE, AS SHOWN. WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. 4 PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> NAC2 STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE BACKGROUND, THAT READS: <br /> 15CD 15CD 30CD 75CD FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED <br /> WITHIN 20FT OF EACH OTHER. "FIRE ALARM CELLULAR DIALER" <br /> OHO ��0 <br /> ANALOG PHONE LINE STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> (SECONDARY) BUILDING FACP. STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> Q& ov EVT-FA-45-211 STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED ASA NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> 41L <br /> clsSOLE PATH FOR FIRE COMMUNICATIONS. IS NOT SUITABLE AT FACP LOCATION. UPDATE BOM <br /> WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> L :11 SL1:10 <br /> B/11c TO BOEING ENGINEER. <br /> SLC 3/4"C - 4#12 *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ 6 FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> ORDINANCES. <br /> WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> BUILDING FIRE ALARM SYSTEM RISER "FIRE ALARM CELLULAR ANTENNA" <br /> SCALE: NONE 17506 <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> SCALE: NONE E260 17506 PRINTEDS LABEL, HANDWRITTENHANDWR TTEELLUAR ON EINFORMATION PIS ROVIDE <br /> 45-211 BUILDING SYSTEM FACP POINTS ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> INFORMATION TO BOEING ENGINEER. <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. <br /> L1:001 1 SMK @ FACP FACP SMOKE DETECTOR - B3/E260 <br /> L1:002 2 SMK OFFICE WEST OFFICE EAST SMOKE DETECTOR - A1/260 <br /> L1:003 3 SMK OFFICE CENTER OFFICE CENTER SMOKE DETECTOR - A2/260 <br /> _1:004 4 SMK OFFICE WEST OFFICE WEST SMOKE DETECTOR - A3/260 <br /> L1:005 5 HEAT WOMEN RESTROOM WOMENS R.R. HEAT DETECTOR - A5/260 BILL OF MATERIALS <br /> _1:006 6 HEAT MEN RESTROOM MENS R.R. HEAT DETECTOR - A5/260 ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> L1:007 7 MAN PULL DR N1 N.E. EXIT MANUAL PULL - A3/260 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> L1:008 8 MAN PULL DR N1 N.W. EXIT MANUAL PULL - A4/E260 2 1 3992769 POTTER UD-2000 DACT CARD <br /> _1:009 9 MAN PULL DR S1 SOUTH EXIT MANUAL PULL - 34-17260 3 8 3992732 POTTER PAD100 611 BASE <br /> L1:010 10 45-298 SMK EAST BLDG. 298 EAST SMOKE DETECTOR - Ai/lE60 4 6 3992770 POTTER PAD200 PHOTO DETECTOR <br /> L1:011 11 45-298 SMK WEST BLDG. 298 WEST SMOKE DETECTOR - A3/lE60 1 5 2 3992735 POTTER PAD100 HEAT DETECTOR(135° FIXED) <br /> 6 3 3992720 POTTER PAD100 PULL STATION <br /> 7 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> BUILDING FACP POINTS LIST 8 2 BK-P2RL SYSTEM SENSOR HORN/STROBES <br /> SCALE: NONE 17506 9 2 BK-SCRL SYSTEM SENSOR STROBES <br /> 10 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> 11 1 SSU00689 SPACEAGE FIRE ALARM STORAGE CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> NEW FIRE MONITORING PANEL REPLACEMENT 27851053 CSL MDK 09.15.22 THIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM DETAILS 27851053 .28.23 0 <br /> SPECIFICATION IS APPROVED SHEET <br /> BOE//VG® E506 <br /> A SHOP DRAWINGS AGOW/JS 04.28.23 APPROVED BY DEPT. DATE TITLE <br /> CHECKED <br /> ete L nBUILDING 45-211 JOB Na. DMP Na. <br /> .mE.amm�wmn=,�a APPROVED <br /> APPROVED ELECTRICAL MASTER EVERETT, WA DWG No. 45-211-17506 <br />