My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-279 2023-11-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-279
>
3003 W CASINO RD BLDG 45-279 2023-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:53:44 PM
Creation date
11/29/2023 1:49:47 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-279
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FACP BATTERY CALCULATIONS <br /> COMPONENTS QTY. STANDBY ALARM PEM POWER CABLE (SUPPLIED <br /> CURRENT CURRENT WITH PEM) <br /> NETLINK (FACP) 1 0.15830A 0.30000A 6 5 3 4 <br /> (DACT) 1 0.02400A 0.03700A <br /> SLC DEVICES SUPERVISORY ALARM <br /> CURRENT CURRENT <br /> DS-PS 2 O.oO015A 0.00022A 0.00030A 0.00044A <br /> DS-HFS 0 O.oO015A 0.00022A 0.000OOA 0.000OOA <br /> DUCT 0 O.oO040A 0.00044A 0.000OOA 0.000OOA <br /> 84-330002-001 1 0.00058A 0.00058A 0.00058A 0.00058A <br /> 70-407008-001 0 0.00024A 0.00024A O.00000A 0.00700A - 2 <br /> 70-200200-001 0 0.00020A 0.00040A O.ODDOGA O.000OOA [j_:::-3/4"C 2#14THHN,1#140 TG-PEM <br /> 70-408004-001 0 0.00024A 0.00024A O.000OOA O.000OOA <br /> STANDBYALARM <br /> CURRENT C <br /> .11OOO0. <br /> T FACP EVi-FA-45-729 TG-71C <br /> S <br /> NAC CKT 1(AUX PWR) 0.018A 0.11000A 01800A 0.11000A <br /> NAC CKT 2 o.00A 0.28100A o.000OOA 0.40800A (BY FIRE ALARM VENDOR) <br /> o.00A o.000OOA O.00000A o.000OOA R <br /> SLC ALARM LED O.00A 0.03600A 0.000OOA O.000OOA JG TOTAL 0.20118A 0.85602A <br /> TOTAL STANDBY CURRENT DRAW= 0.2012 AMPS ❑ T <br /> X STANDBY TME 48 HOURS DC STC2 STCI TRIP BATT AC <br /> STANDBY AMP HOUR TOTAL= 9.657 AH <br /> TOTAL ALARM CURRENT DRAW= 0.856 AMPS 1 2 1 2 3 4 5 6 Fl-2--31 1 2 <br /> 00 0 �0 BB <br /> X ALARM TIME 0.167 HOURS <br /> ALARM AMP HOUR TOTAL= 0.143 AH -_K <br /> STANDBY AH + ALARM AH = 9.80 AH RE0 EOL(ns nEcoEo) <br /> X DE-RATING FACTOR 1.20(20%) <br /> TOTAL AH REQUIRED= 11.76 AH <br /> MINIMUM BATTERY SIZE NEEDED: 12 AH <br /> BATTERY SIZE PROVIDED: 12 AH <br /> NOTE: 0.167 EQUALS 10 MINUTES OF ALARM TIME (1) G - (1) PHONE GABLE, <br /> (1) 2 CONDUCTOR FPL OR <br /> APPROVED EQUAL <br /> FACP VOLTAGE DROP CALCULATION <br /> CIRCUIT SUPPLY ALARM OHMS NGT TOTAL LAST DEVICE VOLTAG <br /> NAME VOLTAGE CURRENT WIRE TYPE 1000 F. FEET RESISTANCE VOLTAGE DROP% <br /> NAC1(AUX) 20.4 VDC 0.110 A #14AWG SOLID 3.07 10 0.0614 20.393 VDC 0.03% <br /> NAC2 20.4 VDC 0.408 A #14AWG SOLID 3.07 42 0.2579 20.30 VDC 0.52% FIRE ALARM SYSTEM COMMUNICATIONS DETAIL CONSTRUCTION NOTES <br /> N/A 20.4 VDC 0.000 A #14AWG SOLID 3.07 0 0 00.00 VDC o% SCALE: NONE 117260 17506 <br /> N/A 20.4 VDC 0.000 A #14AWG SOLD 3.07 0 0 00.00 VDC 0% PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> COMPATIBLE WITH AT&T CELL SERVICE. <br /> 41 � PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> Q O O GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> 4c ocn� STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON BUILDING FACP. <br /> MONITORED BY TYCO AND DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> F 1:03 S _1:02 S _1:01 ANAL G PHON LINh SIGNAL SENT TO CENTRAL STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS <br /> (PRIMARY BOEING FIRE DEPARTMENT TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. POWER SUPPPOWER AND LY•PROVIDETH NPOWERMAND17EXPANSION BUILDING FACP <br /> WP45-729 FACP SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE,AS SHOWN. COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR MODULE AND WIRE AS SHOWN. MAINTAIN <br /> NAC2 APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> 110CD 135CD BETWEEN POWER AND COMMUNICATION WIRING. <br /> STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR <br /> CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> ANALOG PHONE LINE WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. BACKGROUND, THAT READS: <br /> (SECONDARY) STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE <br /> EVF-FA-45-729 FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED "FIRE ALARM CELLULAR DIALER" <br /> WITHIN 20FT OF EACH OTHER. <br /> PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM <br /> A'/10b" BUILDING FACP. STRENGTH IN ACCORDANCE WITH DETAIL 2 INSTALL <br /> CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A IS NOT SUITABLE AT FACP LOCATION. UPDATE BOM <br /> SOLE PATH FOR FIRE COMMUNICATIONS. WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> BUILDING FIRE ALARM SYSTEM RISER TO BOEING ENGINEER. <br /> SCALE: NONE E506 * 6 FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ <br /> ORDINANCES. WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> "FIRE ALARM CELLULAR ANTENNA" <br /> INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE PRINTED <br /> AND G17ANDW PHONE NUMBER. PROVIDE <br /> PRINTED LABEL, HANDWRITTEN INFORMATION IS NOT <br /> 45-729 BUILDING SYSTEM FACP POINTS SCALE: NONE 17260 E506 ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> INFORMATION TO BOEING ENGINEER. <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. <br /> L1:001 122 SMK OFFICE N FACP SMOKE DETECTOR - B3/E260 BILL OF MATERIALS <br /> _1:002 123 SMK OFFICE S OFFICE WEST SMOKE DETECTOR - 33/260 ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> L1:003 124 MAN PULL DR W1 OFFICE CENTER SMOKE DETECTOR - A2/260 1 1 76-800100-001 KIDDE ARIES FIRE ALARM CONTROL PANEL <br /> 2 1 76-800015-001 KIDDE ARIES DACT CARD <br /> BUILDING FACP POINTS LIST 3 2 DS-SB KIDDE DETECTOR BASE <br /> SCALE: NONE E506 4 2 DS-PS KIDDE PHOTO DETECTOR <br /> 5 1 84-330002-001 KIDDE DOUBLE ACTION PULL STATION <br /> 6 2 SLA1106 POWERPATROL 12VDC 12 AH BATTERIES <br /> 7 1 BK-P2RL SYSTEM SENSOR HORN/STROBES <br /> 1 8 1 1 BK-P2RK 11SYSTEM SENSOR IWEATHERPROOF HORN/STROBE <br /> 9 1 1 TG-7FS-A TELGUARD IATT CELLULAR DIALER <br /> 10 1 1 ISSU00689 SPACEAGE IFIRE ALARM DOCUMENT CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEAGGBPTAB LTY <br /> NEW FIRE MONITORING PANEL REPLACEMENT 27851053 MDK TT 09.19.22 SPDRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> HIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM DETAILS 27851053 A 04.28.23 0 <br /> ECIFICATION IS APPROVED SHEET <br /> A SHOP DRAWINGS AGOW/JS 04.28.23 BOElrw" m APPROVED BY DEPT. DATE ENGINEER TITLE E506 <br /> CHECKED <br /> ete Linamen APPROVED BUILDING 45-729 JOB N0. COMP NO. <br /> Gu� ma."� APPROVED ELECTRICAL MASTER EVERETT, WA DWG NO. 45-729-E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.