My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-279 2023-11-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-279
>
3003 W CASINO RD BLDG 45-279 2023-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:53:44 PM
Creation date
11/29/2023 1:49:47 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-279
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REGULATORY INFORMATION INTEGRATION OF DETECTORS <br /> North American CAN/ULC-S529-09, UL 268, UL 268A, DS-PS detectors can be mixed in any order with SmartOne <br /> standards FM Approvals 3230 legacy detectors on a Kidde Fire Systems intelligent control unit <br /> UL/cUL smoke 0.9 to 3.50%/ft. (2.95 to 11.48%/m) running SmartOne protocol. <br /> sensitivity range obscuration (Open Area Use <br /> 0.9 to 2.0%/ft.(2.95 to 6.56%/m)obscuration COMPATIBLE CONTROL UNITS <br /> (In-Duct Use) Kidde ARIES NETLink <br /> NOTE: Detector sensitivity is selected at Kidde ARIES <br /> s <br /> control unit or with remote configuration Kidde PEGAsys <br /> software. Fenwal FenwaINET 8000-ML <br /> Default is 2.0%/ft(Alarm), 1.5%/ft(PreAlarm) Fenwal FenwaINET 6000 <br /> FCC compliance This device complies with part 15 of the FCC Fenwal FenwaINET 2000 <br /> Rules. Operation is subject to the following <br /> two conditions: (1)This device may not cause Chemetron MICRO MLX <br /> harmful interference, and (2)this device must Chemetron MICRO SLX <br /> accept any interference received, including <br /> DS Series detectors are compatible with FenwaINET 2000 <br /> interference that may cause undesired erferen. and PEGAsys control units running software version 82.4. <br /> �Industry Canada This Class A digital apparatus complies with Note that FenwaINET 2000 and PEGAsys control units are <br /> compliance Canadian ICES-003. no longer UL Listed or FM Approved. DS Series detectors <br /> have not been compatibility-tested on legacy control units <br /> older than FenwaINET 2000 and PEGAsys. <br /> -- - - - - - - - - 0 - - - - - - -- - - - - - - <br /> TO SMARTONE DS-PS or DS-HFS <br /> CONTROL UNIT CPD-7052,PSD-7152 DETECTOR TO <br /> OR or THD-7252 DETECTOR . NEXT <br /> ANOTHER DETECTOR <br /> DETECTOR i <br /> (Not Polarity <br /> Sensitive) 7 O <br /> - - - - - - - - - - - - - - - - - - - - - - - - <br /> Figure 1: Combining Legacy Detectors with DS Series Detectors <br /> (Class B, Style 4 Wiring Style Shown) <br /> NOTES: SOFTWARE NOTE: <br /> 1. Detectors are not polarity sensitive.Terminals 3 and 7 The DS-PS detector does NOT support configurable alarm <br /> (SmartOne)or Terminals 2 and 4(DS Series)can be settings below 0.9%/ft. If a DS-PS is configured with a thresh- <br /> reversed. old below 0.9%/ft.for Alarm or 0.7%/ft.for Pre-Alarm,the detec- <br /> 2. SmartOne and DS Series detectors can be installed in any for will operate at the lowest allowable setting. If the control unit <br /> order. is running software version 1.2.11 (for Single Loop panel) or <br /> 3. SLC loop is not sensitive to the location of the control unit software version 2.1.2 (for Multi-Loop panel) or later, the mes- <br /> (can be left or right end of loop). sage `INVALID THRESHOLD" will be reported on the Keypad/ <br /> 4. Four-wire loops will be wired as above, bringing loose end Display. However, if the control unit is running an older version <br /> of loop back to the control unit. of software, no message will be reported. <br /> K-76-101 3 ' Kidde <br /> Effective:January 2017 Fire Systems <br />
The URL can be used to link to this page
Your browser does not support the video tag.