SYSTEM DESIGNATIONS EQUIPMENT/DEVICES RECEPTACLES ABBREVIATIONS GENERAL_ NOTES <br /> $ SINGLE POLE TOGGLE SWITCH DUPLEX,1 5A,1 20V,l 0,2P,3W, PARALLEL BLADE,GROUNDED. GE GENERAL ELECTRIC 1. CABLE TIES USED FOR LOW VOLTAGE TELEPHONE,PAGING OR DATA CABLES IN PLENUM <br /> HASH MARKS INDICATE THE QUANTITY OF CONDUCTORS GEN GENERATOR <br /> (#12 WIRE UNLESS OTHERWISE NOTED). IF UNMARKED $P SINGLE POLE TOGGLE SWITCH WITH PILOT LIGHT FOUR PLEX-2 DUPLEX 15A,10,2P,3W, PARALLEL BLADE GROUNDED. OF GROUND FAULT SPACES SHALL BE DESIGNED FOR USE IN PLENUM AREAS AND MEET UL94V-0 <br /> INSTALL 2#12 IN 1/2"CONDUIT *30 SINGLE, 30A, 48OV, 30, 4 POLE, WITH GFCI GROUND FAULT FLAMMABILITY REQUIREMENTS. <br /> PHASE CONDUCTORS $3 THREE-WAY TOGGLE SWITCH BACK BOX, GROUND THRU EXTRA POLE AND SHELL. CIRCUIT INTERRUPTER 2. ALL CONDUITS CROSSING THE BUILDING EXPANSION JOINT AT COL F-F' TO HAVE <br /> NEUTRAL CONDUCTOR(IF REQUIRED) $K KEY SWITCH 20 GRN GREEN <br /> GROUND CONDUCTOR(IF REQUIRED) DUPLEX,20A,120V,10,2P,3W, PARALLEL BLADE,GROUNDED GND GROUND EXPANSION COUPLINGS WITH 8" MOVEMENT. <br /> 3V34-1V-0A/7,9,11 $LV SWITCH FOR LOW-VOLTAGE SWITCHING SYSTEM HTR HEATER <br /> 3/4"C,3#8 PANEL PANEL/CIRCUIT RUN INDICATES THE NUMBER OF LOW VOLTAGE SWITCHES SIG WITDUPH ISOLATED OGROUND,, ORANGELLEL BLADE HGT HE 3. PROJECT SCOPE IS TO DEMOLISH THE EXISTING 350KW DIESEL FIRED GENERATOR <br /> CONDUIT/CONDUCTORS $LV(2) AS NOTED ON DRAWING. (EG. (2) INDICATES TWO PO HID HIGH INTENSITY DISCHARGE SET LOCATED IN BLDG 40-30 AND CONNECT THE EXISTING ELECTRICAL LOADS TO <br /> 2" UNLESS SWITCHES AT THIS LOCATION) FOUR PLEX-2 DUPLEX, 20A,10,2P,3W, PARALLEL BLADE GROUNDED. HZ HERTZ THE 750KW GENERATOR SET SERVING BLDG 40-21. THE EXISTING AUTOMATIC <br /> CONDUIT RUN EXPOSED, ALL CONDUITS 112" 20 HPS HIGH PRESSURE SODIUM TRANSFER SWITCH IS TO BE DEMOLISHED. NEW EMERGENCY AND STANDBY AUTOMATIC <br /> OTHERWISE REQUIRED OR NOTED $oc LIGHTING SWITCH WITH OCCUPANCY SENSOR SINGLE, 20A, 120V, 10, 2P, 3W, STRAIGHT BLADE, GROUNDED HV HIGH VOLTAGE TRANSFER SWITCHES AND DISTRIBUTION EQUIPMENT ARE TO BE PROVIDED. WORK <br /> ------- CONDUIT RUN CONCEALED IN WALLS, ABOVE CEILING, IN FLOOR 3o HORIZ HORIZONTAL SHALL INCLUDE THE SEPARATION OF EMERGENCY AND STANDBY LOADS. WORK SHALL <br /> SLAB OR UNDERGROUND $M MOTOR RATED SWITCH, 120V, 15A, 10 SINGLE, 30A, 120V, 10, 2P, 3W,STRAIGHT BLADE, GROUNDED HE HORSEPOWER INCLUDE MOVING BRANCH CIRCUITS AND FEEDERS FROM EXISTING PANELBOARDS TO <br /> 3o N NCH NEW AND/OR EXISTING PANELBOARDS THUS PROVIDING SEPARATION. WORK SHALL <br /> -T- TELEPHONE, 3/4" MINIMUM CONDUIT ONLY, UNLESS SIZED O PUSHBUTTON STATION SINGLE, 30A, 208V, 10, 2P, 3W, STRAIGHT BLADE, GROUNDED NFO INFORMATION INCLUDE THE ADDITION OF NEW ELECTRICAL DISTRIBUTION EQUIPMENT. THE NEW AND <br /> OTHERWISE <br /> -E- EMERGENCY CIRCUIT ® MANUAL MOTOR STARTER WITH OVERLOADS AND 20 SINGLE, 20A, 120/208V, 10, 3P, 4W, POLARIZED, SC AMPS SHORT CIRCUIT EXISTING ELECTRICAL EQUIPMENT, DEVICES, FIXTURES, RECEPTACLES, OUTLETS, <br /> JB JUNCTION BOX DISCONNECT SWITCHES, CABINETS, APPARATUS, ETC. ARE TO BE LABELED AND/OR <br /> PILOT LIGHT STRAIGHT BLADE, GROUNDED kcmil THOUSAND CIRCULAR MILLS <br /> -Fa- FIRE ALARM CIRCUIT RE-LABELED ACCORDING BE LABELED AND/OR RE-LABELED IS SHOWN IN THIS PLAN <br /> ® , 10, 3P, 4W, POLARIZED,MAGNETIC MOTOR STARTER s° SINGLE, 60A, 120/208V, KW KILOWATT <br /> / SET THEREFORE, CIRCUIT TRACING AND FIELD INVESTIGATIONS ARE NECESSARY TO <br /> -PA- PAGING CONDUIT WITH WIRE AS NOTED STRAIGHT BLADE, GROUNDED KWH KILOWATT HOUR COMPLETE LABELING WORK. <br /> COMBINATION STARTER, CIRCUIT BREAKER TYPE, KV KILOVOLT <br /> -G- COPPER GROUND WIRE, SIZE AS NOTED 30A UNLESS NOTED OTHERWISE 2, DUPLEX, 20A, 120V, 10, 2P, 3W, STRAIGHT BLADE, KVA KILOVOLT AMPS <br /> GROUND FAULT CIRCUIT INTERUPTING. 4. PROVIDE COMPLETE GENERATOR SET INSTALLATION PRIOR TO TAKING EXISTING <br /> -Lv- LOW VOLTAGE CONDUIT/WIRE ENCLOSED CIRCUIT BREAKER SIZE AS NOTED LGTH LENGTH GENERATOR SETS OFF-LINE. POWER OUTAGES ARE TO BE KEPT TO A MINIMUM. <br /> ON DRAWING FLOOR MOUNTED LST LABOR SAVING TANDEM <br /> -Fc- FIBER OPTIC, 3/4" MIN., WITH CABLE AS INDICATED, UNLESS FOUR PLEX-2 DUPLEX 15A, 10, 2P, 3W,PARALLEL BLADE GROUNDED. LT LIGHT <br /> SIZED OTHERWISE. NO CONDULET FITTINGS IN FIBER OPTIC ❑� DISCONNECT SWITCH, FUSED, 30=SWITCH RATING, LG LONG <br /> RUNS ALLOWED. 30/20 DOSCONNEC ATSWTCH, NON-FUSED, 30A INGX30 FLOOR MOUNTED MA MILLI AMP <br /> SINGLE, 30A, 208V, 10, 2P, 3W, TWISTLOCK, GROUNDED MAG MAGNETIC LABELING AND SIGN REQUIREMENTS, <br /> -c- COMMUNICATIONS CIRCUIT Q' UNLESS NOTED OTHERWISE IN CARPET MOUNTED COMBINATION COMM POWER MMAINTENANCE <br /> ® / MCC <br /> MOTOR CONTROL CENTER A. PROVIDE SIGNS AS REQUIRED FOR EMERGENCY AND OPTIONAL STANDBY SYSTEMS <br /> CONDUIT TURNED UP ® MOTOR CONTROLLER C WITH ONE DUPLEX 20A, 10, 2P, 3W, RECEPTACLES AND TEL/DATA JACKS MFG MANUFACTURER IN ACCORDANCE WITH WAC 296-466-700 AND WAC 296-466-702. <br /> CONDUIT TURNED DOWNEDCEILING MOUNTED 20A, 10, 2P, 3W RECEPTACLE,HUBBELL CAT NO 5362 MAX MAXIMUM B. PROVIDE EMERGENCY SYSTEMS EQUIPMENT IDENTIFICATION IN ACCORDANCE WITH <br /> CAPACITOR A MEZZ MEZZANINE WAC 296-4613-700. EXISTING PANELBOARDS THAT ARE DESIGNATED TO BECOME <br /> 1A CONDUIT IDENTIFICATION 0 TRANSFORMER, SIZE AND TYPE AS NOTED MIN MINIMUM <br /> IRE ALARM SYSTEM MG MOTOR-GENERATOR PART OF THE "EMERGENCY" SYSTEM SHALL BE RENAMED AND RE-LABELED TO <br /> CABLE TRAY, SIZE AS NOTED ON THE DRAWINGS MOTOR, 120V,10, SIZE AS NOTED MISC MISCELLANEOUS REFLECT THEIR EMERGENCY DESIGNATION AS INDICATED IN THE 'PANEL <br /> -V-t-r FLEXIBLE CONDUIT, 1/2" UNLESS NOTED OTHERWISE EQ <br /> ELEVATOR ALARM BELL MTD MOUNTED NOMENCLATURE' IDENTIFICATION BREAKDOWN SHOWN BELOW. <br /> 4 MOTOR, 208V, 30, SIZE AS NOTED ®Q FIRE ALARM HORN/STROBE, WALL OR CEILING N NEUTRAL NEC NATIONAL ELECTRIC CODE <br /> r1,F�J' PREWIRED FLEXIBLE CONDUIT PROVIDED WITH LIGHT FIXTURE C. EXISTING BACKUP SYSTEMS AND/OR EQUIPMENT SUCH AS FEEDERS, TRANSFER <br /> TYPE R, R-2, S AND S-2 AS LSTLABOR SAVING TANDEM MOTOR, 460V, 30, SIZE AS NOTED S SMOKE DETECTOR NO NORMALLY CLOSED SWITCHES, DISTRIBUTION SWITCHBOARDS, PANELBOARDS, ETC., THAT ARE TO <br /> LST (LABOR O NIC NOT IN CONTRACT REMAIN IN SERVICE BUT ARE NOT CLASSIFIED AS "EMERGENCY" SYSTEMS SHALL <br /> >� CONDUIT TO BE REMOVED © JUNCTION BOX, FIELD SIZED OR AS NOTED O HEAT DETECTOR NO NORMALLY OPEN BE RENAMED AND LABELED AS STANDBY SYSTEMS IN ACCORDANCE WITH THE <br /> EQUIPMENT TO BE REMOVED (EG. PANELBOARD) J❑ JUNCTION BOX, SQUARE 4" NS NEUTRAL SENSOR 'PANEL NOMENCLATURE' IDENTIFICATION BREAKDOWN SHOWN BELOW. <br /> 00 LXX MANUAL STATION, SUBSCRIPT INDICATES TYPE NTS NOT TO SCALE <br /> WP = WEATHERPROOF, IF" = EXPLOSIONPROOF D. ALL EXISTING FEEDERS, BRANCH CIRCUITS, BOXES, ENCLOSURES, EQUIPMENT, <br /> (E) EXISTING GROUNDING PIGTAIL No. OR # NUMBER RECEPTACLES, OUTLETS, ETC., THAT ARE FED FROM A RENAMED PANELBOARD OR <br /> ® PULLBOX, FIELD SIZED OR AS NOTED ❑AR XX WATERFPRELOW SWITCH, NO SUBSCRIPT = VANE TYPE OC ON CENTER SWITCHBOARD SHALL BE RE-LABELED TO MATCH THE NAMING USED FOR THE <br /> JB JUNCTION BOX, SPECIAL. FIELD SIZED OR AS NOTED "PD" = PRESSURETYPEOD <br /> W/DELAY OP POLE D OUTSIDE DIAMETER PANELBOARD OR SWITCHBOARD IN ACCORDANCE WITH THE ABOVE PARAGRAPHS AS <br /> DISTRIBUTION PA PUBLIC ADDRESS APPLICABLE TO "EMERGENCY" AND "STANDBY" SYSTEMS. <br /> N TELEPHONE OUTLET, WALL MOUNTED PS HI/LO AIR PRESSURE SWITCH PNL PANEL <br /> ® PANELBOARD, 480V, 30, 3W, PANELBOARD K DATA OUTLET, WALL MOUNTED % PERCENT <br /> El PUSHBUTTON STATION, TYPE AS NOTED ❑VS TAMPER SWITCH (VALVE SWITCH) PERP PERPENDICULAR PANEL NOMENCLATURE <br /> e PANELBOARD, 48OY/277V, 30, 4W, PANELBOARD, 0 OR PH PHASE <br /> _ ® REMOTE RELAY (OR MON/CTRL MODULE) <br /> SURFACE MOUNTED, FLUSH MOUNTED O THERMOSTAT PVC POLYVINYL CHLORIDE XE 3 V30-1 U D12-1-D <br /> © CONTACTOR, TYPE AS NOTED FATC FIRE ALARM TERMINAL CABINET PWR POWER <br /> v SUFFIX "-D" INDICATES DISTRIBUTION PANEL <br /> 1� PANELBOARD, 208Y/120V, 30, 4W, OR 30, SW PANELBOARD PF POWER FACTOR <br /> SURFACE MOUNTED, FLUSH MOUNTED © CONTROL PANEL FRCP FIRE ALARM CONTROL PANEL PE PRESSURE ELECTRIC SUFFIX "-1, -2, -3, ETC." IS USED TO <br /> Mcc MOTOR CONTROL CENTER ® RELAY PB PUSHBUTTON INDICATE MULTIPLE PANELS AT SAME LOCATION <br /> I INDICATES WALL MOUNTING PR PAIR WHICH ARE SAME VOLTAGE, FED FROM SAME <br /> PT POTENTIAL TRANSFORMER VAULT AND LOCATED ON SAME FLOOR <br /> [� SPECIAL PANEL AS NOTED O TELEPHONE AND DATA/POWER POLE QTY QUANTITY <br /> PROVIDED BY SYSTEMS FURNITURE MFR. RECP RECEPTACLE NOTE: IF SUFFIX "-A, -B, -C, ETC." IS BEING <br /> BUSWAY WITH BUSPLUG, CIRCUIT BREAKER REF REFERENCE USED INSTEAD OF "-1, -2, -3, ETC.", THEN <br /> SIZE AS NOTED 0 TELEPHONE AND DATA/POWER POLE REQ'D REQUIRED CONTINUE USING SUFFIX LETTERS FOR CLARITY <br /> PROVIDED BY ELECTRICAL CONTRACTOR ABBREVIATIONS RREV GS RIGID REVISION <br /> OGALVANIZED STEEL <br /> ® COMBINATION FLUSH FLOOR BOX WITH PANEL LOCATION AT NEAREST COLUMN <br /> SINGLE LINE DIAGRAM FOUR NEMA 5-15R OUTLETS A AMP DC DIRECT CURRENT RM ROOM LOCATION OF PANEL WHEN NOT ON FIRST FLOOR: <br /> AA AMBIENT AIR DED DEDICATED CIRCUIT SECT <br /> SECTION <br /> M = MEZZANINE U = 2ND FLOOR <br /> SHIS <br /> ® COMBINATION FLUSH FLOOR POKE-THRU WITH A/C AIR CONDITIONING DEG DEGREE P = PENTHOUSE UT = UTILIDOR <br /> CIRCUIT BREAKER, AIR, DRAW OUT FOUR NEMA 5-15R OUTLETS AC ALTERNATING CURRENT DET DETAIL SIM SIMILAR R = P1 PARKING FLOOR V = 3RD FLOOR <br /> AC-X AIR CONDITIONING UNIT - X DAM DIAMETER SPDT SINGLE POLE DOUBLE THROW S = P2 PARKING FLOOR W = 4TH FLOOR <br /> ® FUSESPST SINGLE POLE SINGLE THROW <br /> AUXILIARY SYSTEMS AF AMP FRAME DISC DISCONNECT SPEC SPECIFICATION T = TRUSS LEVEL X = 5TH FLOOR <br /> A.F.F. ABOVE FINISHED FLOOR DPDT DOUBLE POLE DOUBLE THROW TN = TUNNEL <br /> TRANSFORMER $V P.A. SYSTEM ATTENUATOR, WALL MOUNTED, AHU-X AIR HANDLING UNIT - X DPST DOUBLE POLE SINGLE THROW ST SHUNT TRIP <br /> 10 WATT RATING AT AMP TRIP DN DOWN SUB SUBSTATION SOURCE OF POWER: VAULT N0. <br /> AWG AMERICAN WIRE GAUGE DWG DRAWING SUSP SUSPEND <br /> S SW SWITCH FLIGHTLINE EXAMPLE: VS38M CURRENT TRANSFORMER FOR SUBSTATION S38 <br /> SPEAKER, RECESSED MOUNTED IN CEILING AMP AMPERE (E) EXISTING <br /> (EQ GONG, SIZE AS SPECIFIED APPROX APPROXIMATE EA EACH SYS SYSTEM VOLTAGE AND ASSOCIATED PANEL SYMBOL: <br /> _j_ GROUND ® ANNUNCIATOR ARCH ARCHITECT OR ARCHITECTURAL ELECT ELECTRIC <br /> AUTO AUTOMATIC EMT ELECTRICAL METALLIC TUBING TEL TELEPHONE ® 4 = 48OV, 3PH, 3W <br /> AUX AUXILIARY EVER EMERGENCY TR TRIP RELAY ® 3 = 480Y/277V, 3PH, 4W <br /> ® AMMETER ® TELEPHONE CABINET BOT BOTTOM ENGR ENGINEER T'STAT THERMOSTAT o 2 208Y/12OV, 3PH, 4W OR 120/24OV, 1 PH, 3W <br /> BLDG BUILDING EQUIP EQUIPMENT XFMR TRANSFORMER O 5 = 400 HZ, 575Y/331V, 3PH, 4W <br /> 0 VOLTMETER Q LIMIT SWITCH C DEGREE CENTIGRADE ETC ETCETERA TYP TYPICAL © 2 = 400 HZ, 200Y/1 15V, 3PH, 4W <br /> CAB CABINET EWC ELECTRIC WATER COOLER UH UNIT HEATER [� <br /> ENCLOSED CIRCUIT BREAKER 1 = 28 VDC <br /> ® COMBINATION FLUSH FLOOR BOX WITH CAT CATALOG EXIST EXISTING UG UNDERGROUND LON UNLESS OTHERWISE NOTED <br /> EPO VERT VERTICAL <br /> LL-i SIZE AS NOTED TELEPHONE/DATA/AV SYSTEM ROUGH-IN CB CIRCUIT BREAKER EXTR EXTERIOR PREFIX: <br /> CLG CEILING EXP EXPLOSION PROOF <br /> GENERATOR SET ❑� EMERGENCY POWER OFF CTR CENTER FA FORCED AIR V VOLT, VAULT (BLANK) NORMAL POWER PANEL <br /> _ <br /> GEN. SEE ELECTRICAL ONE-LINE CHWR CHILLED WATER RETURN FDR FEEDER WE WEATHERPROOF "I" = ISOLATED GND PANEL <br /> #3 DIAGRAMS EMERGENCY POWER OFF SYSTEM WH WATER HEATER "Z" = 400 HZ PANEL <br /> RELAY PANEL <br /> CHWS CHILLED WATER SUPPLY FIXT FIXTURE <br /> = <br /> GENERATOR SET EPS CKT CIRCUIT FLEX FLEXIBLE W WATT "XE" EMERGENCY PANEL <br /> SEE SITE PLAN O GROUND ROD COAX COAXIALFLR FLOOR W/ WITH "XL" = LEGALLY REQUIRED STANDBY PANEL <br /> COL COLUMN A FLUOR FLOURESCENT W/O WITH OUT "XS" = OPTIONAL STANDBY PANEL 1 <br /> 0_7 LOAD BREAK SW. C CONDUIT FT FOOT Z IMPEDANCE <br /> C.O. CONDUIT ONLY <br /> CONT CONTINUE *NOTE: SEE DRAWING 40-031-E506 <br /> CU COPPER FOR ADDITIONAL FIRE ALARM ABBREVIATIONS. <br /> CT CURRENT TRANSFORMER <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> TAH ACCEPTABILITY <br /> BNS R S.CHECKED <br /> Os 20 23 ELECTRICAL SYMBOLS AND ABBREVIATIONS 30391984 A 08/21/23 <br /> A EVERETT 40-30/31 BLDG FIRE PANEL EXPANSION 30391984 FASDESIGN AGOW/PL 08/21/23 A- 1 <br /> K.M. 09 21 23 SHEET SEQUENCE No. <br /> SPECIFICATIONIS APPROVED TITLE EOAPPROVED eY DEPT. DATE K.M. Oa is 23EVERETT FIRE PANEL REP AGEMENTCHECKED APPROVED BUILDING 40-030 JOB N0. COMP N0. <br /> 30391984 <br /> APPROVED EVERETT, Wq, DWG No. 40-030-EO <br />