3003 W CASINO RD BLDG 40-30 2023-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-30
>
3003 W CASINO RD BLDG 40-30 2023-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2023 8:09:23 AM
Creation date
11/30/2023 6:34:37 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-30
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> SYSTEM SEQUENCE OF OPERATION SEE SHEET EO FOR LEGEND AND ABBREVIATIONS <br /> 1. ALARM CONDITION: A <br /> Ior <br /> 1.1 ACTIVATION OF ANY ALARM SHALL CAUSE THE FOLLOWING: <br /> a. Alarm indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display ALARM POINT LOCATION INFORMATION. <br /> d. Activate FACP DACT, transmit ALARM signal to Central Station monitoring company. <br /> 2. SUPERVISORY CONDITION: <br /> 2.1 ACTIVATION OF ANY SUPERVISORY CONDITION SHALL CAUSE THE FOLLOWING: GENERAL NOTES <br /> a. Supervisory indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display SUPERVISORY POINT LOCATION INFORMATION. <br /> d. Activate FACP DACT, transmit SUPERVISORY signal to Central Station monitoring company. <br /> 3. TROUBLE CONDITION: <br /> 3.1 ACTIVATION OF ANY TROUBLE CONDITION SHALL CAUSE THE FOLLOWING: <br /> a. Trouble indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display TROUBLE CONDITION. <br /> d. Activate FACP DACT, transmit TROUBLE signal to Central Station monitoring company. <br /> REFERENCE DRAWINGS <br /> FIRE ALARM SYSTEM SEQUENCE OF OPERATION <br /> SCALE: NONE E506-4 <br /> BILL OF MATERIALS <br /> PART # ITEM DESCRIPTION UNIT QTY. <br /> ARIES NETLINK FIRE ALARM CONTROL PANEL (EXISTING) EA 1 <br /> 70-610001-001 ADDRESSABLE CONTACT INPUT DEVICE EA 28 <br /> 40-30/31 WEST BILL OF MATERIALS n CONSTRUCTION NOTES <br /> SCALE: NONE E506-4 <br /> ARIES NETLINK POWER SUPPLY AND BATTERY SIZE CALCULATION - 40-30/31 BUILDING <br /> TOTAL STAND-BY CURRENT PER SYSTEM: 0.369 AMPS <br /> TOTAL ALARM CURRENT PER SYSTEM: 0.545 AMPS <br /> ENTER STAND-BY HOURS: 48 HOURS <br /> ENTER ALARM TIME: 10 MINUTES <br /> AMPERE HOUR REQUIRED: 17.81 AH <br /> TOTAL AMP HOUR REQUIRE(DERATING FACTOR 1.2): 22.00 AH <br /> BATTERY SIZE REQUIRED PER SYSTEM (TWO(2) BATTERIES REQUIRED): 22 AH <br /> 2-TIERED MAIN OR EXPANSION ENCLOSURE, MAX. 20 AMPS* 15 AMPS <br /> EXPANSION ENCLOSURE(S) REQUIRED? YES <br /> NUMBER OF ENCLOSURE(MAIN/EXPANSION) REQUIRED: 1 <br /> NUMBER OF POWER MANAGEMENT UNIT(PMU) BOARD REQUIRED: 1 <br /> NUMBER OF POWER SUPPLY UNIT(PSU) REQUIRED: 1 <br /> TOTAL TOTAL <br /> ITEM STANDBY STANDBY ALARM ALARM <br /> NO DESCRIPTION QTY (AMPS) (AMPS) (AMPS) (AMPS) <br /> 1 VICE(WITH KEYBOARD/DISPLAY) 1 0.15830 0.15830 0.30000 0.30000 <br /> 2 DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT) EXPANSION CARD 1 0.02400 0.02400 0.03700 0.03700 <br /> 3 REMOTE DISPLAY CONTROL MODULE(RDCM) 1 .090000 0.09000 0.09100 0.09100 <br /> 4 SMARTONE PHOTOELECTRIC SMOKE DETECTOR OS-PS 7 0.00015 0.00105 0.00022 0.00154 <br /> 5 SMARTONE CONTACT INPUT MODULE(AI'S, N/0) 47 0.00058 0.02726 0.00058 0.02726 <br /> 6 POWER MANAGEMENT UNIT(PMU) BOARD#1, MAX. 10.8 AMPS 1 1 0.07000 1 0.07000 1 0.09000 0.09000 <br /> TOTALS <br /> EVTFA40-30/31 WEST FIRE ALARM CONTROL PANEL BATTERY CALCULATIONS <br /> SCALE: NONE E50`6-4 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATED SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY ,f,$, Q$20 23 <br /> THIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM DETAILS 30391984 A 08/21/23 <br /> A EVERETf 40-30/31 BLDG FIRE PANEL EXPANSION 30391984 FASDESIGN AGOW/PL 08/21/23 K.M. 08/21/23 SHEET SEQUENCE NO. <br /> SPECIFICATION IS APPROVED ry IN TITLE E506 4 <br /> APPROVED BY DEPT. DATE K.M. 08/18/23 EVERE T FIRE PANEL REPLACEMENT <br /> CHECKED <br /> E eau° APPROVED BUILDING 40-031 <br /> APPROVED EVERETT, WA, DWG NO. 40-031-E506-4 <br />