My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST INDEX HALL 2023-12-29
>
Address Records
>
TOWER ST
>
2000
>
INDEX HALL
>
2000 TOWER ST INDEX HALL 2023-12-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 9:15:26 AM
Creation date
12/1/2023 1:34:09 PM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
INDEX HALL
Notes
LAWN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ld <br />fl- <br />/ I !n <br />IE(E)=117!5 10"RCP <br />\ <br />®\ <br />6" DIP PER <br />F <br />n <br />CITY GIs <br />= <br />(APPROXIMATE <br />\ <br />LOCATION) <br />\ <br />2 <br />—.as <br />as <br />was <br />aS <br />S <br />1 II <br />/125 <br />1 <br />SDMH RIM=123.96 <br />I R \ <br />')6 <br />IE(W)=115.36 <br />8"PVC <br />IRS <br />IVY <br />IE(N)=113.96 <br />10"STEEL <br />/ <br />F <br />IE(SE)=119.06 <br />6"PVC <br />26 <br />/ <br />N <br />r 127 <br />I I <br />126 <br />I 1 <br />TWEE <br />O <br />1 <br />/ 130 <br />214 <br />s� <br />I <br />i <br />\i <br />\1\ <br />I J <br />1 <br />I <br />6" ISO 0 1.1% <br />/so <br />I C <br />/ 70LF 3/4" TYPE K <br />/ COPPER <br />NNW)-)=1119.50 �""PVC <br />IE(NE9.9:�1/4�PVC <br />A 3 \ <br />Vv� A <br />v <br />I <br />9 <br />\ LP h\ P p P P <br />\ X ❑ P <br />\ Y <br />\ ELEC HH <br />\ <br />YD 1 \ <br />RIM:121.6 \ <br />IE:119.9 (SE) 4" \ <br />IE:119.7 (SW) 6" <br />4"S000.68%� \ <br />^1 \ <br />120.2 <br />\ <br />\ <br />\ <br />\ <br />GRAVEL TRENCH <br />CONC <br />�I 2I.4-Q\/ <br />IT 131.672J - <br />1� d— d 10' TRE6 d �\ ❑ELEC HH <br />m O <br />� SION� O \ HC SIGN d REE- <br />iREE \ <br />p 1 STEPS CONC <br />I \ <br />0 G b b & 6� <br />z G & <br />G <br />1 \ i <br />\, CB RIM=122.41 <br />TW:133.60 <br />� nlnl.l q� co IE(N)=117.91 10"PVC <br />SCALE <br />IN <br />FEET <br />10 <br />0 <br />10 <br />20 <br />CA, 0AI P <br />Archi[eafure & Plannin <br />LEGEND 1011 SW KIJCKITAT WAY, STE.208 <br />SEATTLE, WA 98134 1 (206) 631-8442 <br />W WATER MAIN PIPE hops:/Aw .mps.mm <br />CONSULTANT <br />SD STORM PIPE <br />YARD DRA1Ne • " 1 <br />C501 T7M 9ud 92H <br />Ph 4Z-38W r711 <br />GRAVEL TRENCH DRAIN( mrd01A1[tm.m <br />C501 <br />PROFESSIONALSTPMP <br />COE CITY OF EVERE17 <br />CONSTRUCTION NOTES: <br />t� 7 CONNECT TO STORM SEWER PIPE WITH WYE FITTING <br />O2 3/4" SERVICE SADDLE CONNECTION PER COE STD DETAIL 501 <br />(1) 3/4" HOSE BIB/YARD HYDRANT. SEE DETAIL 5/C501 <br />® PROVIDE 1" ORIFICE PLATE. SEE DETAIL 3/C501 <br />NOTES: <br />1. BEFORE COMMENCING CONSTRUCTION OF WATER, <br />EXCAVATE TO VERIFY LOCATION AND INVERT ELEVATION <br />OF THE WATER PIPES TO BE CONNECTED TO PROPOSED <br />SYSTEM. IF A CONFLICT EXISTS, CONTACT THE ARCHITECT <br />IMMEDIATELY. <br />2. BEFORE COMMENCING CONSTRUCTION OF STORM SYSTEM <br />VERIFY LOCATION OF EXISTING STORM PIPE AND INVERT <br />ELEVATION. IF CONFLICT EXISTS, CONTACT THE ARCHITECT <br />IMMEDIATELY. <br />3. SEE DETAIL A/C501 FOR TYPICAL TRENCH SECTION. <br />4. THE CONTRACTOR SHALL USE A PRIVATE UTILITY LOCATING <br />SERVICE TO IDENTIFY ALL UTILITIES PRIOR TO ANY <br />EXCAVATION. <br />5. PROTECT EXISTING UTILITIES TO REMAIN DURING <br />CONSTRUCTION. <br />UTIUTY CROSSING NOTES: <br />INSTALL WATER SVC BELOW IRRIGATION WITH 6 <br />VERTICAL CLEARANCE MINIMUM <br />STANDARD WATER NOTES: <br />1. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY <br />MEANS OF AN APPROVED BACKFLOW PREVENTION DEVICE PRIOR TO <br />SATISFACTORY FLUSHING, TESTING, DISINFECTION, AND RECEIPT OF <br />SATISFACTORY BACTERIOLOGICAL TEST RESULTS. <br />2. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE <br />PUBLIC WORKS DEPARTMENT AT THE DEVELOPER'S EXPENSE. THE PUBLIC <br />WORKS DEPARTMENT SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS <br />NOTICE FOR EACH CONNECTION. THE PUBLIC WORKS DEPARTMENT SHALL <br />THEREAFTER DETERMINE THE DATE AND TIME AT WHICH THE CONNECTION <br />SHALL BE MADE. <br />3. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT <br />STANDARDS. <br />4. A PRE -CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO <br />THE START OF CONSTRUCTION. THE CITY OF EVERETT PUBLIC WORKS <br />CONSTRUCTION DIVISION MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR <br />TO COMMENCEMENT OF CONSTRUCTION. <br />5. THE DEVELOPER OR THE DEVELOPERS AUTHORIZED AGENT SHALL NOTIFY <br />THE PUBLIC WORKS DEPARTMENT OF A PERSON WHO CAN BE CONTACTED <br />REGARDING PROBLEMS DURING CONSTRUCTION ON A 24 HOUR BASIS. <br />6. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL <br />SEPARATION BETWEEN POTABLE AND NON -POTABLE CONVEYANCE <br />SYSTEMS. <br />7. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC WORKS <br />DEPARTMENT PERSONNEL ONLY. ALL VALVES, NEW AND EXISTING, SHALL <br />BE ACCESSIBLE AT ALL TIMES. <br />jj EVERETT <br />2000 TOWER STREET <br />EVERETT,WA98201 1 (425)3883100 <br />hfps:lly .evemfm.edu <br />W <br />cri <br />W U) <br />J Z <br />U � <br />L W <br />r <br />0 <br />a wN <br />CO <br />~ Lu <br />1 W <br />04 <br />04 ~ J H <br />O <br />04 <br />w <br />it uJ 0_ <br />W w <br />o W� LNw <br />A <br />u, <br />w <br />X <br />HEFT NO. I TITLE: <br />CU 101 <br />STORM AND <br />UTILITIES —PLAN <br />M City of Everett <br />EVERETT Reviewed for Permit 07/09/2022 <br />....".... PROJECT NUMBER: 2022-1 T4 G (1-1) <br />
The URL can be used to link to this page
Your browser does not support the video tag.