• <br /> Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at <br /> energycode©energy.wsu.edu or(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Proposed 2 bedrooms and utility room garage conversion,interior Carmelo N Laviste <br /> alterations,bathroom remodel,4 bedrooms,1.5 bath addition and <br /> existing lower floor into an adult family home. <br /> Heating System Type: 0 All Other Systems i! Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word'Instructions" <br /> Design Temperature <br /> Instructions _._ wµ :.:.w Design Temperature Difference(AT) 47 <br /> Everett 1C r AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> iilht:iaa:tll€)`i Conditioned Floor Area(sq ft) 1,283 <br /> Average Ceiling Height Conditioned Volume <br /> itlstructioiis Average Ceiling Height(ft) 7.8 10,050 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> U 0.20 0.200 40 7.99 <br /> Skylights U-Factor X Area = UA <br /> lrlet.ructions 0.50 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> instructions <br /> t:^R a9 0.026 962 25.01 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> lnstruc non$ <br /> 'Select R-Value No selection <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> instructions • <br /> R.21 Intermediate 0.056 998 55.90 <br /> Floors U-Factor X Area UA <br /> Instructions No selection <br /> Select R-Value ► <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions <br /> Select R•value . No selection <br /> Slab Below Grade(see Figure 1) F-Factor X Len th UA <br /> instructions 4 <br /> Select conditioning . No selection <br /> Slab on Grade(see Figure 1) F-Factor X Len s th UA <br /> instriictic"l' € 0.540 149 80.46 <br /> .. R-10 Perimeter <br /> Location of Ducts <br /> instructions Duct Leakage Coefficient <br /> Unconditioned Space '► <br /> 1.10 <br /> Sum of UA 169.36 <br /> Envelope Heat Load 7,960 Btu/Hour <br /> Figure 1. Sum of UA x AT <br /> Air Leakage Heat Load 5,101 Btu/Hour <br /> •= Volume x 0.6 x AT x 0.018 <br /> Above Grade Building Design Heat Load 13,061 Btu/Hour <br /> • Air leakage+envelope heat loss <br /> Building and Duct Heat Load 14,367 Btu/Hour <br /> Ducts in unconditioned space:sum of building heat loss x 1.10 <br /> Ducts in conditioned space:sum of building heat loss x 1 <br /> Maximum Heat Equipment Output 17,959 Btu/Hour <br /> Building and duct heat loss x 1.40 for forced air furnace <br /> Building and duct heat loss x 1.25 for heat pump <br /> (07/01/13) <br />