Laserfiche WebLink
ALS Enuironmenta1 <br /> CERTIFICATE OF ANALYSIS <br /> CLIENT: GeoEngineers, Inc. DATE: 7/23/2020 <br /> 1101 Fawcett Ave. S., Suite 200 ALS SDG#: EV20070042 <br /> Tacoma, WA 98402 WDOE ACCREDITATION: C601 <br /> CLIENT CONTACT: Jacob Letts <br /> CLIENT PROJECT: Smith St. Mill <br /> I LABORATORY BLANK RESULTS <br /> MB-07142OW- Batch 155482 -Water by SW8260C Prepared 07/14/20 00:00 <br /> n-Butylbenzene SW8260C ND U UG/L 2.0 0.16 0.48 07/14/20 DLC <br /> 1,2-Dichlorobenzene SW8260C ND U UG/L 2.0 0.12 0.37 07/14/20 DLC <br /> 1,2-Dibromo-3-Chloropropane SW8260C ND U UG/L 10 0.0085 0.027 07/14/20 DLC <br /> 1,2,4-Trichlorobenzene SW8260C ND U UG/L 2.0 0.13 0.38 07/14/20 DLC <br /> Hexachlorobutadiene SW8260C ND U UG/L 2.0 0.17 0.50 07/14/20 DLC <br /> Naphthalene SW8260C ND U UG/L 2.0 0.12 0.36 07/14/20 DLC <br /> 1,2,3-Trichlorobenzene SW8260C ND U UG/L 2.0 0.13 0.38 07/14/20 DLC <br /> SPIKE CONTROL LIMITS ANALYSIS ANALYSIS <br /> SURROGATE METHOD %REC QUAL ADDED RESULT MIN MAX DATE BY <br /> 1,2-Dichloroethane-d4 SW8260C 102 5.00 5.11 71 130 07/14/20 DLC <br /> Toluene-d8 SW8260C 99.0 5.00 4.95 80 120 07/14/20 DLC <br /> p-Bromofluorobenzene SW8260C 99.8 5.00 4.99 78 120 07/14/20 DLC <br /> U-Analyte analyzed for but not detected at level above reporting limit. <br /> MB-07132OW- Batch 155432 -Water by SW8270DSIM Prepared 07/13/20 00:00 <br /> LIMITS ANALYSIS ANALYSIS <br /> ANALYTE METHOD RESULTS QUAL UNITS RL MDL PQL DATE BY <br /> Naphthalene SW8270DSIM ND U UG/L 0.020 0.00078 0.0024 07/13/20 JMK <br /> 2-Methylnaphthalene SW8270DSIM ND U UG/L 0.020 0.0017 0.0052 07/13/20 JMK <br /> 1-Methylnaphthalene SW8270DSIM ND U UG/L 0.020 0.0010 0.0030 07/13/20 JMK <br /> Acenaphthylene SW8270DSIM ND U UG/L 0.020 0.0025 0.0074 07/13/20 JMK <br /> Acenaphthene SW8270DSIM ND U UG/L 0.020 0.0036 0.011 07/13/20 JMK <br /> Fluorene SW8270DSIM ND U UG/L 0.020 0.0011 0.0033 07/13/20 JMK <br /> Phenanthrene SW8270DSIM ND U UG/L 0.020 0.0021 0.0063 07/13/20 JMK <br /> Anthracene SW8270DSIM ND U UG/L 0.020 0.0027 0.0082 07/13/20 JMK <br /> Fluoranthene SW8270DSIM ND U UG/L 0.020 0.00061 0.0018 07/13/20 JMK <br /> Pyrene SW8270DSIM ND U UG/L 0.020 0.0013 0.0038 07/13/20 JMK <br /> Benz[a]anthracene SW8270DSIM ND U UG/L 0.020 0.0010 0.0031 07/13/20 JMK <br /> Chrysene SW8270DSIM ND U UG/L 0.020 0.0021 0.0062 07/13/20 JMK <br /> Benzo(b)fluoranthene SW8270DSIM ND U UG/L 0.020 0.0030 0.0091 07/13/20 JMK <br /> Benzo(k)fluoranthene SW8270DSIM ND U UG/L 0.020 0.0049 0.015 07/13/20 JMK <br /> Benzo(a)pyrene SW8270DSIM ND U UG/L 0.020 0.0023 0.0069 07/13/20 JMK <br /> Indeno(1,2,3-cd)pyrene SW8270DSIM ND U UG/L 0.020 0.0018 0.0055 07/13/20 JMK <br /> Dibenzo(a,h)anth racene SW8270DSIM ND U UG/L 0.020 0.0036 0.011 07/13/20 JMK <br /> Benzo(ghi)perylene SW8270DSIM ND U UG/L 0.020 0.0020 0.0060 07/13/20 JMK <br /> SPIKE CONTROL LIMITS ANALYSIS ANALYSIS <br /> SURROGATE METHOD %REC QUAL ADDED RESULT MIN MAX DATE BY <br /> Terphenyl-d14 SW8270DSIM 109 2.50 2.73 50 147 07/13/20 JMK <br /> U-Analyte analyzed for but not detected at level above reporting limit. <br /> Page 16 <br /> ADDRESS 8620 Holly Drive, Suite 100, Everett,WA 98208 [ PHONE 425-356-2600 425-356-2626 <br /> ALS Group USA,Corp dba ALS Environmental <br /> www.aisgiobal.com <br /> RIGHT SO1-UTI43f15 -I-I. I-I�1 1-1 <br />