Laserfiche WebLink
ALS Enuironme ntal <br /> CERTIFICATE OF ANALYSIS <br /> CLIENT: GeoEngineers, Inc. DATE: 10/19/2020 <br /> 1101 Fawcett Ave. S., Suite 200 ALS JOB#: EV20100044 <br /> Tacoma, WA 98402 ALS SAMPLE#: EV20100044-04 <br /> CLIENT CONTACT: Jacob Letts DATE RECEIVED: 10/08/20 <br /> CLIENT PROJECT: Smith St. Mill COLLECTION DATE: 10/8/2020 <br /> CLIENT SAMPLE ID TRIP BLANK WDOE ACCREDITATION: C601 <br /> SAMPLE DATA RESULTS <br /> DILUTION LIMITS ANALYSIS ANALYSIS <br /> ANALYTE METHOD RESULTS QUAL UNITS FACTOR RL MDL PQL DATE BY <br /> 1,1,1,2-Tetrachloroethane SW8260C ND U UG/L 1 2.0 0.092 0.28 10/12/20 DLC <br /> Ethylbenzene SW8260C ND U UG/L 1 2.0 0.097 0.29 10/12/20 DLC <br /> m,p-Xylene SW8260C ND U UG/L 1 4.0 0.19 0.57 10/12/20 DLC <br /> Styrene SW8260C ND U UG/L 1 2.0 0.075 0.22 10/12/20 DLC <br /> o-Xylene SW8260C ND U UG/L 1 2.0 0.086 0.26 10/12/20 DLC <br /> Bromoform SW8260C ND U UG/L 1 2.0 0.072 0.22 10/12/20 DLC <br /> Isopropyl benzene(Cumene) SW8260C ND U UG/L 1 2.0 0.099 0.30 10/12/20 DLC <br /> 1,1,2,2-Tetrachloroethane SW8260C ND U UG/L 1 2.0 0.048 0.14 10/12/20 DLC <br /> 1,2,3-Trichloropropane SW8260C ND U UG/L 1 2.0 0.0060 0.018 10/12/20 DLC <br /> Bromobenzene SW8260C ND U UG/L 1 2.0 0.13 0.38 10/12/20 DLC <br /> n-Propylbenzene SW8260C ND U UG/L 1 2.0 0.15 0.46 10/12/20 DLC <br /> 2-Chlorotoluene SW8260C ND U UG/L 1 2.0 0.15 0.44 10/12/20 DLC <br /> 1,3,5-Trimethylbenzene SW8260C ND U UG/L 1 2.0 0.15 0.44 10/12/20 DLC <br /> 4-Chlorotoluene SW8260C ND U UG/L 1 2.0 0.14 0.43 10/12/20 DLC <br /> Tert-Butyl benzene SW8260C ND U UG/L 1 2.0 0.16 0.48 10/12/20 DLC <br /> 1,2,4-Trimethylbenzene SW8260C ND U UG/L 1 2.0 0.14 0.43 10/12/20 DLC <br /> Sec-Butylbenzene SW8260C ND U UG/L 1 2.0 0.16 0.48 10/12/20 DLC <br /> p-Isopropyltoluene SW8260C ND U UG/L 1 2.0 0.16 0.47 10/12/20 DLC <br /> 1,3-Dichlorobenzene SW8260C ND U UG/L 1 2.0 0.13 0.40 10/12/20 DLC <br /> 1,4-Dichlorobenzene SW8260C ND U UG/L 1 2.0 0.13 0.39 10/12/20 DLC <br /> n-Butylbenzene SW8260C ND U UG/L 1 2.0 0.16 0.48 10/12/20 DLC <br /> 1,2-Dichlorobenzene SW8260C ND U UG/L 1 2.0 0.12 0.37 10/12/20 DLC <br /> 1,2-Dibromo-3-Chloropropane SW8260C ND U UG/L 1 10 0.0085 0.027 10/12/20 DLC <br /> 1,2,4-Trichlorobenzene SW8260C ND U UG/L 1 2.0 0.13 0.38 10/12/20 DLC <br /> Hexachlorobutadiene SW8260C ND U UG/L 1 2.0 0.17 0.50 10/12/20 DLC <br /> Naphthalene SW8260C ND U UG/L 1 2.0 0.12 0.36 10/12/20 DLC <br /> 1,2,3-Trichlorobenzene SW8260C ND U UG/L 1 2.0 0.13 0.38 10/12/20 DLC <br /> SPIKE LIMITS ANALYSIS ANALYSIS <br /> SURROGATE METHOD RESULTS QUAL ADDED RESULT MIN MAX DATE BY <br /> 1,2-Dichloroethane-d4 SW8260C 109 5.00 5.44 71 130 10/12/20 DLC <br /> Toluene-d8 SW8260C 99.0 5.00 4.95 80 120 10/12/20 DLC <br /> p-Bromofluorobenzene SW8260C 104 5.00 5.22 78 120 10/12/20 DLC <br /> U-Analyte analyzed for but not detected at level above reporting limit. <br /> Page 12 <br /> ADDRESS 8620 Holly Drive,Suite 100, Everett,WA 98208 1 PHONE 425-356-2600 1 FAX 425-356-2626 <br /> ALS Group USA,Corp dba ALS Environmental <br /> www.aisgiobal.com <br /> RIGHT SU1-UTIOf15 -(moi.1 I•nrf t rlEF <br />