STRUCTURAL INFORMATION: STRUCTURAL NOTES: PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5"SPLICE <br /> ROOF TYPE (1): <br /> ROOF TYPE: Comp Shingle <br /> SHEATHING TYPE: PLYWOOD BLUE RAVEN <br /> FRAMING TYPE: Rafter None <br /> FRAMING SIZE: 2x6 @ 24" OC <br /> 1403 N. Research Way <br /> CEILING JOIST SIZE: 2x4 @ 24"OC 23" 72" MAX. - Orem, UT 84097 <br /> ATTACHMENT: SFM Infinity Flashkit MAX. LANDSCAPE <br /> 800.377.4480 <br /> RACKING: Unirac SFM Infinity WWW.BLUERAVENSOLAR.COM <br /> @ 48"OC Portrait/72"OC Landscape PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE CONFIDENTIAL-THE INFORMATION <br /> HEREIN CONTAINED SHALL NOT BE <br /> NUMBER OF ATTACHMENTS: 21 USED FOR THE BENEFIT OF ANYONE <br /> EXCEPT BLUE RAVEN SOLAR NOR <br /> PV MODULE COUNT: 8 ModulesSHALL IT BE DISCLOSED IN WHOLE OR <br /> IN PART TO OTHERS OUTSIDE <br /> TOTAL ARRAY AREA: 163.2 ft2(20.4ft2/panel) RECIPIENTS ORGANIZATION,EXCEPT <br /> TOTAL ROOF AREA: 2204.78 ft2 IN CONNECTION WITH THE SALE AND <br /> USE OF THE RESPECTIVE EQUIPMENT, <br /> ARRAY/ROOF AREA: 7.4% N N WITHOUT THE WRITTEN PERMISSION <br /> ARRAY WEIGHT: 400 lbs(50 lbs/panel) 23 48" MAX. - OF BLUE RAVEN SOLAR LLC. <br /> DISTRIBUTED LOAD: 2.45 Ibs/ft2 MAX. PORTRAIT <br /> POINT LOAD: 19.05 lbs/attachment 'NOTE:LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY ATTACHMENT SPACING- FRONT VIEW -RACKING ATTACHMENTS TO BE STAGGERED NABCEP <br /> BASED ON FIELD CONDITIONS.MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER C <br /> ENGINEER OF RECORD SPECIFICATIONS. SCALE: 3/4" = V-0" CERTIFIED <br /> UNIRAC SFM INFINITY UNIRAC SFM MICRORAIL/SPLICE A PV INSTALLATION <br /> PV MODULE PROFESSIONAL <br /> Scott Gurney <br /> REC SOLAR REC420AA PURE-R 77 #PV-011719-015866 <br /> PV MODULE B PORTRAIT <br /> CONTRACTOR: <br /> 17UNIRAC SFM SLIDER BRS FIELD OPS <br /> � � <br /> ROOF STRUCTURE 800-377-4480 <br /> (E) ROOF MODULE <br /> Oo SHEATHING WIDTH <br /> FLASHING � A <br /> _ U U <br /> (1)5/16" STAINLESS STEEL LAG BOLT zz BQ 0 <br /> WITH 2-1/2" MIN. EMBEDMENT LANDSCAPE <br /> AND FLAT WASHER 2Y2" MIN. EMBED. 18° O OM <br /> 00 <br /> WIDTH <br /> co <br /> _ MODULE <br /> WIDTH � N 01) cV M <br /> Q > O W W <br /> MIDDLE/TOP STANDOFF DETAIL ATTACHMENT SPACING- SIDE VIEW Z __ 0, N N <br /> A (E) BUILDING STRUCTURE D N <br /> SCALE: 3" = V-0" SCALE: 1/2" = V-0" 00 �r <br /> W }' O M W W <br /> REC SOLAR REC420AA PURE-R p U j co <br /> PV MODULE O j.- >. >. <br /> Sister upgrade is required for N Y LO C. N U) <br /> (MP1) on all rafters that directly :3E � > v v <br /> UNIRAC SFM TRIMRAIL support solar PV. Stitch new Sealed For U I— r— W Q <br /> FLASHING 2x6 DF#2 (min) to existing Existing Roof& DRAWING BY: <br /> UNIRAC SFM SLIDER AND member. See detail for Attachment Only p Cq L Brendan Fillmore <br /> SH <br /> TRIMRAIL ROOF ATTACHMENT ROOF additional information. `�► WAS <br /> SHEATHING PLOT DATE: <br /> a+ September 20, 2023 <br /> (1)5/16" STAINLESS STEEL LAG BOLT PROJECT NUMBER: <br /> WITH 2-1/2" MIN. EMBEDMENT 864080 <br /> AND FLAT WASHER 21/2" MIN. EMBED. 46056 <br /> �FCjSTERb� �<v� SHEET NAME: <br /> �rs"'ONAL - STRUCTURAL <br /> BOTTOM STANDOFF DETAIL REVISION PAGE NUMBER <br /> SCALE: 3" = V-0" (E) BUILDING STRUCTURE 9/20/23 0 PV4 <br />