Laserfiche WebLink
• • <br /> 9/,7 <br /> :i I it, :+sing the"Fly-In"Method,place your thumbs down.It makes the job easier to hot weather,to let go of the sticky <br /> WinterGuard.(Thanks to Mike Dempsey ofEafle Riser,1W.) <br /> there are no wrinkles.Once adhered,they will not blow off the • WinterGueed may not come in contact with excessive amounts of <br /> roof,They do not leak around nails driven through them,because petroleum solvent-based cements,such as asphalt phtstic cement. <br /> the thick layer of polymer-modified asphalt coating is designed to For use with WinterGuard,CertainTeed recommends urethanes or <br /> be sticky and flexible,so it seals around the nails that puncture it. polymer-modified cements.Use such materials sparingly, <br /> Therefore,these underlayments are not lust water-resistant,they are + Du not apply over shingles.With the exception of certain roof <br /> waterproof.But they must be applied fully adhered to a clean,dry penetration flashing details do not apply over water-resistant <br /> wood deck,in accordance with the manufacturer's specifications,in underlayment' <br /> order to get the promised performance.And nails must be properly + if necessuy,you may apply new WinterGuard overall older existing <br /> set according to manufacturer's requirements. piece of WSU;however,be sure the following conditions are met in <br /> HOW i5 Wl#7E12Gl3ARD MADE AND HOW DOES IT WORK? order for the WincerGuardwarranty to remain in force: <br /> WinterGuard i<._.-ompusitr materiel of acphai[and elastume it: •The nndertyiag roof deekmus.be acceptable and in good condition. <br /> polymers reinforced with a fiber;pa s membrane it is formed into •The existing WSU must have a smooth,clean surface.Nail holes <br /> arolled sheet.The rubberized asphalt provides ihr eaterproohng. can be present,but all shingles,nails,etc must be removed <br /> The polymers make the asphalt elastic and sticky all the wit, throug t and the existing WSU surface swept clean. <br /> the membrane This means WinterGuard has the_biltri: both •The surface of the existing WSU must be primed with an <br /> stretch end cling,and not rip when stressed It seal,like a guskei ASSTM D41 asphalt primer in order to achieve proper <br /> around is is driven through it,it sticks to a clean roof deck like glue adhesion when applying all surface style versions of <br /> and is warranted to remain effective for the life of the nevi 4apilsih WinterGuard. <br /> shingle system applied over it,up to 50 years. •All laps must be offset between the existing WSU and new <br /> WinterGuard by at team S". <br /> HERE ARE SOME OTHER FACTS •"Feather'the high edge of the WinterGuard over the existing <br /> WSU to avoid telegraphing its double thickness. <br /> ABOUT 1NTEG H A RD <br /> �_..__.,.. Note:CertainTeed is not responsible for and disclaims any and <br /> all liability for any damage caused by incompatibility of its <br /> • WinterGuarde)is available in two different surface styles— WinterGuard products when applied over WSff from other <br /> sand and granular.WinterGuard-HT(high tack and high manufacturers. <br /> temperature)has a film surface,it is more flexible than sand • Do not use WinterGuard as a permanently exposed roofing surface <br /> or granular surfaced WinterGuard and can withstand high because it will begin to degrade after too much exposure to <br /> temperature roof applications,Including metal or tile. ultraviolet light.However,after being properly applied to an <br /> *+ WinterOuar0 Metal is also film-surfaced and designed for use with acceptable deck,WinterGuard can be left exposed for three to <br /> metal or mechanically fastened tile roof applications. six months(depending on the weather)prior to the installation <br /> and 3' of the roofing shingles—without significantly damaging <br /> • The standard roll of WinterGuard is 65'in length <br /> WnterGuard's performance in the finished system.When <br /> wide.One standard roll contains 195 square feet of material. exposing WinterGuard for more than one day,we strongly <br /> Sand-surfaced WinterGuard and WinterGuard HT also comes in recommended that you: <br /> a handy"Short Roll"that is 32 tr•long and 3'wide.It contains <br /> 97 Ili square feet of material. • Press down all laps with a wallpaper seam roller to assure immediate <br /> adhesion.End laps should be 6".Side laps for film and granular <br /> • A roll of WinterGuard Metal is 61'in length and 39W wide surfaced should be 4";sand surfaced requires a 6'side lap. <br /> rientalnfng 200 square feet of material, <br /> • Use additional fasteners to hold the sheet in place(especially if <br /> • During installation,an initial light"tack"(stickiness)makes cool,windy weather is anticipated). <br /> WinterGuard easy to lift if you accidentally put it in the wrong place. <br /> The aggressive"tack"of WinterGuard-HT is not as forgiving. • Close-off holes and joints in the roots,since the finished roofing system <br /> and its flashing components will not be in place to prevent leakage. <br /> + Once WinterGuard is installed,however,it locks right after <br /> being warmed by the sun.If an immediate seal is desired,press • Prior to roofing over the exposed WinterGuard,inspect It for <br /> overlaps firmly with a roller.A heavy-duty wallpaper scum roller damage and replace or recover any worn areas.tf any fasteners <br /> or"J"roller works well. are removed,the WinterGuard must be replaced or the holes <br /> must be filled with one of the adhesives mentioned above so that <br /> CdUTION: it remains watertight. <br /> • To help prevent shingles from fusing to the waterproofing underpay- <br /> ment,you can cover sand or granular-surfaced WinterGuard with a <br /> layer of feltunderiayment or use film-surfaced WinterGuard HT or <br /> WinterGuard Metal.Although not required,adopting this practice <br /> .Nomi•Datle County atzeptancc requires the amazon of winlerGaard see mcchanidty <br /> will serve the property owner and your fellow roofing contractor toteucd aso tett or i43 true sheet,and not&Gtcctlr to thedeek Such application is acceptable <br /> well when it comes time for the next re-roof. only when required by local wile In arc where ice damming does not•ruse.Doing du mg not <br /> orlect the pronto,limited wurane.. <br /> I EhtTii\rEFU stif!t,,.f IPPei6iiri k'y vttlt ,tt 43 <br />