Laserfiche WebLink
,- <br /> ARCHITECTURAL REPAIRS FOR :.t' 'X D ' 1 SYMBOLS NOTES <br /> ',is!‘4,•."'14$,.•.";'.,V6';-----2- ''.. <br /> FAMILY TREE APARTMENTS BLDG G ,-4) -1,, COLUMN LINE GRID INDICATOR GENERAL SYMBOLS Project <br /> 10110 19TH AVE SE R301 EVERETT,WA 98208 .,,.,t,„-. , L:,. .., .,Q00,,,:. , „A„,,,--,- .. 1: , ALPHABETIC IN SEQUENCE & AND North <br /> I, ., '''Per: -rCou --•'5(1,j;- i '. :. e - <br /> NORTH ARROW <br /> IC :-..) -, 1- . p •INVERCIIEST -,. '. @ AT <br /> DRAWING LIST REVISION DRAWING LIST REVISION r <br /> ," : , <br /> Interoty S....I.,' _ '. ,..'Jai.: '''-:-/:' -V't ' <br /> 7.1 -!' ,,.: ' ,.-.,., r 2.:.,•.,,,..,_,-:-.,n=-:-54. 1,, ! - _ 0 c(COLUMN LINE ID et, CENTER LINE <br /> # NUMBER <br /> G000 DRAWING LIST,PROJECT SCOPE. - •• -: ,to • e _. -., 0 DIAMETER <br /> DESIGN CRITERIA % PERCENT <br /> A101 PARTIAL FLOOR PLANS - ' --"is FAMILY TREE , I. ...;• *4. .140.,,- = EQUAL TO I 1"' REFERENCE <br /> 0 NUMERIC IN SEQUENCE BOUNDARY <br /> A501 DETAILS - ' ."-':' ''APARTMENTS •-• Il '4 /0"."-Ct/- <br /> IN CREEKS.: A "' > GREATER THAN I I <br /> . <br /> < LESS THAN <br /> \-1 0 6 1. Ls, i r•-\\ !I;A, '' -af,..:teir-Clti ...'.'..'. ••16 .r ', <br /> : .... --- ,,...r.- DOOR OPENING IDENTIFIER _?_ GREATER THAN OR EQUAL TO i I DETAIL DESIGNATION <br /> (NUMBER) <br /> 37;:N <br /> .-...:, '.. <br /> / ' • - 'Fir. . , <br /> %5 .0q:C" '''.4 II;; - '‘' <br /> t itfli'' 0-..----DOOR ID LESS THAN OR EQUAL TO <br /> It PROPERTY LINE •-- - gli <br /> DRAWING NUMBER OF <br /> 117 <br /> (NUMBER) / PER THE SHEET WHERE THE <br /> '' .' ,- ,..'.h-•"' *174 . nt .t.41- '. Pi WI . r';-.-!‘ 4 <br /> \ STATION EQUIPMENT DETAIL IS SHOWN <br /> ! , ' ,14.,,C, . ".*. .1,. ' -'1 ,! , EQUIPMENT IDENTIFIER BREAKLINE <br /> 1 mAy 1 1 2023 J ., . at. <br /> . A.i.• ' 41 Asil"'. - -, -A .stc- ELEVATION POINT <br /> 0-...-EQUIPMENT ID 0 1ST FLOOR PLAN <br /> U. ALIGN <br /> (- 1-ry OF r.--.,-4, <br /> EVERE I h- 0 VICINITY PLAN <br /> SCALE NTS ROOM IDENTIFICATION ABBREVIATIONS <br /> ADDL ADDITIONAL <br /> ..,_"1.-; -A O XXXX -ROOM NAME BTWN BETWEEN <br /> Permit Services <br /> ixxxxi-ROOM NUMBER DBL DOUBLE <br /> ', • ' I ,IIIIII' en I EA EACH SECTION DESIGNATION <br /> -cri.,,,ii- APPROXIMATE EJ EXPANSION JOINT LOCATION E (LETTER) <br /> EXISTING Ai I DRAWING NUMBER OF <br /> / • OF PROPERTY LINE WALLTYPE IDENTIFIER FV FIELD VERIFY <br /> BUILDING DATA -* 1117 THE SHEET WHERE THE <br /> •• IN INFORMATION NO. REVISED FOR DATE DI IY-M- <br /> ADDRESS 10110 19TH AVE SE#R200 EVERETT.WA 98208 ' ' fr -- 0 7-WALL TYPE ID KSI KIPS PER INCH DETAIL IS SHOWN - <br /> MAX MAXIMUM - <br /> PARCEL 28051900100200 . ' 11•1111110MMOIIIMIIMIIIIIMIUMIE•11 MIN MINIMUM 2. <br /> _ <br /> 3.. 110 Ar yherc _ ... . ' WINDOW IDENTIFIER N NEW <br /> STORIES' 3 <br /> • ' • V.,..1., . - 4 <br /> '7 . NTS NOT TO SCALE -4. <br /> YEAR BUILT 1994 • , :,:.--, Its : rjrn7, : ;-, I e-WINDOW TYPE ID O.C. ON CENTER ELEVATION ORIENTATION - <br /> SLOPE IDENTIFIER PSF POUNDS PER SQUARE FOOT <br /> 5. <br /> I 41' . PL PLATE <br /> USE GROUP: R-2 PSI POUNDS PER SQUARE INCH <br /> d". NU <br /> DRAWING NUMBER OF 7. <br /> or • . • / *. • <br /> CONSTR.TYPE. VB THE SHEET WHERE THE <br /> -0 ./0 ,•41P- -.7S..- . '. '''% I PT PRESERVATIVE(PRESSURE)TREATED <br /> RISK CATEGORY: II -- ' - . 1 Illim. R&R REMOVE AND REPLACE DETAIL IS SHOWN <br /> - . '--'-' - .-' ', '.... • - i' t - <br /> 12 REDO REQUIRED i=•zi RimKus <br /> .._ Au-7- r--: nob-11•4 <br /> Or .....-SLOPE ID <br /> SIM SIMILAR <br /> 1 7 - <br /> I Z": I <br /> t STL STEEL <br /> 1 12 <br /> TA TRIBUTARY AREA REVISION IDENTIFIER ELEVATION IDENTIFICATION <br /> DOVVN OR UP 16932 WOODINVILLE REDMOND ROAD NE A105 <br /> 1 16 4% 4 . „. , „ , , ,. . ..•,:.%1ILY TREE TS TUBE STEEL <br /> 1 ' PAR-VENTS U NO UNLESS NOTED OTHERWISE A T.O. WOODINVILLE,WA 95072 <br /> 4 ibbriak aiuki;-'14 . .i.......k.. , i 0 VIF VERIFY IN FIELD EXPEPT@RIMKUS.COM <br /> W/ WITH <br /> 0 SCHEMATIC SITE PLAN 0 WE WOOD SCREW <br /> CD SEAL 71,45111-8 <br /> DESIGN CODE CRITERIA PROJECT SCOPE GENERAL NOTES <br /> 1. CONSTRUCTION SHALL FOLLOW THE REQUIREMENTS OF THE FOLLOWING CODES AND AMENDMENTS AS 1.THE INTENT OF THESE DRAWINGS IS TO REPAIR WALL AND 1.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND <br /> ADOPTED BY THE STATE OF WASHINGTON AND EVERETT CITY 2021 WASHINGTON STATE BUILDING CEILING FINISHES DUE TO WATER DAMAGE. ACCESSIBILITY PRIOR TO BEGINNING WORK ANY DISCREPANCIES ‘4•VVIaiinif$9,0:44. <br /> CODE AND THE WASHINGTON STATE EXISTING BUILDING CODE WITH LOCAL BUILDING CODE FOUND SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT <br /> 2.THE DRAWINGS DETAIL THE SCOPE OF ARCHITECTURAL WORK. ARCHITECT/ENGINEER ANY NECESSARY ADJUSTMENTS SHALL BE <br /> AMENDMENTS. MADE PER PROJECT ARCHITECT/ENGINEER'S WRITTEN DIRECTION <br /> 3.THERE ARE NO ADDITIONS OR RECONFIGURATIONS OF THE FLOOR PLAN Additional Permits Are Require ' DI <br /> 2.ALL DESIGN CHANGES SHALL BE SUBMITTED IN WRITING FOR REVIEW NO. ISSUED FOR DATE(Y-M.. <br /> BY THE PROJECT ARCHITECT/ENGINEER .. <br /> 4.THE INTERIOR FLOOR,WALL AND CEILING FINISHES WILL BE 3.ALL WRITTEN DIMENSIONS PER PLAN TAKE PRECEDENCE OVER For This Project To Include: <br /> APPROVED DEMOLISHED AND REPLACED IN-KIND DUE TO FIRE AND WATER <br /> DAMAGE SCALED DIMENSIONS DO NOT SCALE DRAWINGS <br /> 4.CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES 3. <br /> 4. <br /> INVOLVED -5. <br /> Office of Community, Planning&Economic Development 5.CONSTRUCTION DETAILS AND FEATURES SHOWN ON DRAWINGS ARE in Plumbing 133 Sprinkler <br /> _ <br /> PLANNING DEPARTMENT TYPICAL AND SHALL BE APPLIED GENERALLY THROUGHOUT THE <br /> ENTIRE PROJECT AT SIMILAR CONDITIONS M Mechanical IA] Fire Alarm 6. <br /> 6.NOTES AND DETAILS LABELED AS TYPICAL,IF INCLUDED,SHALL BE PROJECT <br /> USED UNLESS SPECIFIC NOTES AND DETAILS ARE SHOWN <br /> ELSEWHERE WHERE THEY ARE TO BE APPLIED R1 Electrical -4- -pc,' ,41_ 4,..p. ARCHITECTURAL REPAIR FOR <br /> FAMIY TREE APARTMENTS <br /> NaMc-Drr algila IV DATE: h.03 7.ALL MATERIALS SHOWN OR CALLED FOR ON THESE PLANS SHALL BE <br /> INSTALLED PER MANUFACTURERS WRITTEN/PRINTED 10110 19TH AVE SE#R200 <br /> RECOMMENDATIONS AND SPECIFICATIONS --t) . ----orstt iN:e-c-E- 4k_s-e,Ito.... <br /> EVERETT,WA 98208 <br /> 8.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL <br /> REQUIRED PERMITS FOR THE PROPOSED WORK <br /> 9.THE COORDINATION OF ALL REQUIRED BUILDING DEPARTMENT CLIENT <br /> INSPECTION IS THE RESPONSIBILITY OF THE CONTRACTOR.THE CITY OF EVERETT FIRST ONSITE <br /> CONTRACTOR SHALL MAKE EVERY EFFORT THROUGH PROPER AND 21522 84TH AVE SOUTH <br /> TIMELY NOTIFICATION TO ENSURE THE REPAIRS ARE COMPLETED SANTA BARBARA,CA 93110 <br /> Permit#: B2304-030 WITH MINIMAL DELAY FOR INSPECTIONS .. P\II FWP D FOR 17-) P";- <br /> _,..._ . ... ,..... ,,- : ,:,..,. ,,, <br /> 10.THE GENERAL CONTRACTOR SHALL DETERMINE FROM THE LOCAL SHEET TITLE <br /> Site Address: 10110 19TH AVE SE BUILDING AUTHORITY.AT THE TIME THE BUILDING PERMIT IS DRAWING LIST, <br /> Owner: FAMILY TREE&LINCOLN WAY LLLP OBTAINED,WHETHER LETTERS OF CONSTRUCTION COMPLIANCE WILL <br /> BE REQUESTED FROM THE ARCHITECT/STRUCTURAL ENGINEER.THE PROJECT SCOPE, <br /> Tenant: FAMILY TREE APARTMENTS CONTRACTOR SHALL NOTIFY THE ARCHITECT/STRUCTURAL DESIGN CRITERIA <br /> ENGINEER OF ALL SUCH REQUIREMENTS PRIOR TO THE START OF <br /> App. Date: 4/8/2023 CONSTRUCTION.FOUR DAY ADVANCE NOTICE SHALL BE GIVEN WHEN THESE DOCUMENTS HAVE NOT BEEN FOR CLIENTS SOLE USE PER GOVERNING CONTRACT <br /> REQUESTING SITE VISITS NECESSARY AS THE BASIS FOR THE AND LIMITED TO APPUCABLE PROJECT.NO <br /> Permit Type: COMMERCIAL BUILDING COMPLIANCE LETTER.THE GENERAL CONTRACTOR SHALL PROVIDE APPROVED FOR THE ISSUANCE OF MODIFICATIONS OR REPRODUCTIONS WITHOUT <br /> Subtype: COMMERCIAL ALTERATION(T.I., INTERIOR EcElIVEN, <br /> THE ARCHITECT/STRUCTURAL ENGINEER A MINIMUM OF ONE WEEK <br /> DEMO,ADDITION,ETC) <br /> R . PRIOR TO THE DATE THAT THE COMPLIANCE LETTERS ARE NEEDED <br /> 11.THE STRUCTURE HAS BEEN DESIGNED TO RESIST VERTICAL AND <br /> LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL P SUPPRESSION, ELECTRICAL OR <br /> PLUMBING PERMITS SA LU WRITTEN RESI,OAPNPSRI BOLVEAFLOORFVREIRMI KFYU VERIFYING <br /> GCAOLNLTRAD 1 mCETNOsRi 0Ns SOLELY <br /> COPIES OF ALL THIRD PARTY TESTING AND INSPECTION REPORTS TO PUBLIC WORKS MECHANICAL, FIRE <br /> PROJECT NO <br /> TE TM-M-DI 2023-03-30 <br /> EL <br /> DESIGNEDSCALE BY 100206994 <br /> Description: REPLACE INSULATION AND DRYWALL APR 0 8 2023 jt, CONTRACTOR. <br /> TE EEHBISRNESCPOOMNPSLIEBTILEITDY.SINTCALBUILDITYESO.BFUTTHIES NOT STRUCTURELIMITED ASR NOTEDNKus <br /> UNITS G204 AND G304 -1 PRIOR TO COMPLETION IS THE SOLE RESPONSIBILITY OF THE <br /> • TO JOB SITE SAFETY ERECTION MEANS,METHODS AND SEQUENCES. DRAWN BY DJH <br /> .0, CITY OF EVERETT TEMPORARY SHORING.FORMWORK AND BRACING AND USE OF <br /> CHECKED BY CP <br /> Reviewed By: 4 Date: Allilf-orsit7 EQUIPMENT AND CONSTRUCTION PROCEDURES <br /> . <br /> Permit Services 12.ALL DIMENSIONS INDICATED ON DRAWINGS ARE APPROXIMATE, DRAWING NO <br /> CONTRACTOR TO FIELD VERIFY <br /> .) Office Set Job Site Set G000 <br /> SHEET NO <br />