My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1701 121ST ST SE 2023-12-11
>
Address Records
>
121ST ST SE
>
1701
>
1701 121ST ST SE 2023-12-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2023 11:05:30 AM
Creation date
12/11/2023 11:04:48 AM
Metadata
Fields
Template:
Address Document
Street Name
121ST ST SE
Street Number
1701
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • Project Title: 410 <br /> Long span beams Engineer: <br /> supporting exterior Project De <br /> Pp 9 Project Descr: <br /> landings <br /> Wood Beam File:2023-01-11 Beam Checks.ec6 <br /> Software copyright ENERCALC,INC.1983-2020,Buid:12.20.5.17 <br /> Lic.#:KW-06006102 DIBBLE ENGINEERS INC. <br /> DESCRIPTION: PT Beam <br /> CODE REFERENCES <br /> Calculations per NDS 2018, IBC 2018,CBC 2019,ASCE 7-16 <br /> Load Combination Set:ASCE 7-16 <br /> Material Properties <br /> Analysis Method: Allowable Stress Design Fb+ 1,000.0 psi E:Modulus of Elasticity <br /> Load Combination ASCE 7-16 Fb- 1,000.0 psi Ebend-xx 1,300.Oksi <br /> Fc-Prll 1,000.0 psi Eminbend-xx 1,300.0 ksi <br /> Wood Species : Fc-Perp 1,000.0 psi <br /> Wood Grade Fv 65.0 psi <br /> Ft 65.0 psi Density 34.0 pcf <br /> Beam Bracing : Beam is Fully Braced against lateral-torsional buckling <br /> D(0.12 L(0.3) <br /> i c <br /> r <br /> 6x12 <br /> Span=8.Oft T <br /> w <br /> Applied Loads s Service loads entered. Load Factors will be applied for calculations. <br /> Uniform Load: D=0.040, L=0.10 ksf, Tributary Width=3.0 ft,(Exterior Landing Load) <br /> DESIGN SUMMARY Design OK <br /> Maximum Bending Stress Ratio = 0.33a 1 Maximum Shear Stress Ratio = 0.470 : 1 <br /> Section used for this span 6x12 Section used for this span 6x12 <br /> = 332.59 psi = 30.54 psi <br /> = 1,000.00psi = 65.00 psi <br /> Load Combination +D+L Load Combination +D+L <br /> Location of maximum on span = 4.000ft Location of maximum on span = 7.066ft <br /> Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1 <br /> Maximum Deflection <br /> Max Downward Transient Deflection 0.031 in Ratio= 3128>=360 <br /> Max Upward Transient Deflection 0.000 in Ratio= 0<360 <br /> Max Downward Total Deflection 0.043 in Ratio= 2234>=240 <br /> Max Upward Total Deflection 0.000 in Ratio= 0<240 <br /> Vertical Reactions Support notation:Far left is#1 Values in KIPS <br /> Load Combination Support 1 Support 2 <br /> Overall MAXimum 1.680 1.680 <br /> Overall MINimum 1.200 1.200 <br /> D Only 0.480 0.480 <br /> +D+L 1.680 1.680 <br /> +D+0.750L 1.380 1.380 <br /> +0.60D 0.288 0.288 <br /> L Only 1.200 1.200 <br />
The URL can be used to link to this page
Your browser does not support the video tag.