Laserfiche WebLink
El= <br /> - CC DESIGN LLC <br /> 441www.ccdesign.us <br /> , r Alb, <br /> \111// ': c <br /> Email auOlkingcOc@gmail.com <br /> •'' <br /> SAWCUT10 �" <br /> C) <br /> 00 <br /> CIRCULAR NOTCH �,Pr• BORED HOLES ARE <br /> ' ', TO BE SPACED AT <br /> O ON <br /> II <br /> LEAST A STUD WIDTH (I <br /> • FROM A CUT OR• HNOTCH <br /> VEE NOTCH —� • e <br /> I • H e H <br /> '/ <br /> LET-IN NOTCH —�— .11 /'i II <br /> E"'( j <br /> / TOBORED BE SPACEDHOLES ARE AT <br /> /� A TWICE DI W , <br /> �jJ DIAMETER OF THE �/ H <br /> / LARGEST HOLE 41 W <br /> 8"WIDE STEM WALL� / / . w 4.4 <br /> 12"WIDE FOOTING/ ( <br /> j BEARING WALL STUDS BEARING WALL STUDS V N <br /> ' STUD MAX DEPTH OF MIN DEPTH REMAING STUD MAX DIAMETER MIN DEPTH REMAING Z N--I <br /> SIZE EDGE CUT OR NOTCH AFTER CUT OR NOTCH SIZE OF BORED HOLE AFTER BORED HOLE �( 00 <br /> 2x4 7/8" 2 5/8" 2x4 1 3/8" 5/8"EA SIDE OFHOLE <br /> CA N <br /> 2x6 1 3/8" 41/8" 2x6 2 3/16" 5/8"EA SIDE OFHOLE 11'-0-A- N <br /> NOTE: DBL TOP PLATE <br /> STUDS MAY NOT BE BORED IN EXCESS OF 40%OF THE <br /> STUD,IF STUDS ARE DOUBLED,BORINGS MAY BE 11(2�ROWS 0.148"Ox3 <br /> INCREASED TO 60%OF STUD WIDTH PROVIDED NOT <br /> MORE THAN(2)SUCCESSIVE STUDS ARE BORED. NAILS( 6)TOTAL) <br /> BORINGS SHALL NOT BE MADE AT THE SAME SECTION STAGG WITHIN AREA CLIENT <br /> WHERE CUT OR NOTCH HAS BEEN MADE. OF SC.! E)@ 6"OC Dawen Chen <br /> 1 2228 127th P1 SE, <br /> NON-BEARING WALL STUDS NON-BEARING WALL STUDS Everett 98028 <br /> —PLATE SPLICE TO <br /> STUD MAX DEPTH OF MIN DEPTH REMAING STUD MAX DIAMETER MIN DEPTH REMAING OCCUR OVER <br /> SIZE EDGE CUT OR NOTCH AFTER CUT OR NOTCH SIZE OF BORED HOLE AFTER BORED HOLE STUDS,TYP <br /> 2x4 1 3/8" 2 1/8" 2x4 2 1/16" 5/8"EA SIDE OFHOLE ,..— <br /> 2x6 2 3/16" 3 3/8" 2x6 3 1/4" 5/8"EA SIDE OF HOLE STUD WALL PER PLA9 NO REVISION DATE <br /> NOTE: <br /> STUDS MAY NOT BE BORED IN EXCESS OF 60%OF THE <br /> STUD.BORINGS SHALL NOT BE MADE AT THE SAME 'Ay- -t\f-. -At- ..%. ± <br /> _J SECTION WHERE CUT OR NOTCH HAS BEEN MADE. <br /> L - J <br /> CUTTING AND NOTCHING WOOD STUDS BORED HOLES IN WOOD STUDS <br /> I0'_l On NOTE: NOTE: NOTE: DRAWING TITLE <br /> / / DO NOT NOTCH MORE THAN THREE ADJACENT BORED HOLE NOT PERMITTED IN MORE THAN THREE <br /> „ JST SPAN STUDS WITHOUT REVIEW BY ENGINEER. ADJACENT STUDS WITHOUT REVIEW BY ENGINEER. ROOF JOISTS NOT SHOWN FOR CLARITY. FOUNDATION P LAN <br /> N WALL DETAILS <br /> ®FOUNDATION PLAN O TYPICAL HOLES & NOTCHING IN WOOD STUDS O TYPICAL SPLICE DETAIL <br /> SHEET NO <br /> 1/4"=1' SCALE: N.T.S SCALE: N.T.S <br /> A-002 <br />