Laserfiche WebLink
VERETT <br />0 <br />Permit Inspections <br />City of Everett <br />4/5/2022 <br />4/5/2022 <br />ELEC 06-ROUGH IN <br />STEVE BANKS <br />COVERED W/O <br />eTRAKiT Inspection Request <br />APPROVAL <br />Notes: <br />4/4/2022 11:06 AM NW ELECTRICAL LLC <br />house occupied. <br />Contact Name: Abram <br />Site Address: 4815 BAKER DR <br />Phone:2067184059 <br />e-Mail: NWELECTRICALI2@GMAIL.COM <br />(4/5/2022 11:24 AM SKB) <br />Remove all insulation for visual inspection of all wiring in walls, ceiling and floor. <br />4/6/2022 <br />4/6/2022 <br />ELEC 06-ROUGH IN <br />STEVE BANKS <br />APPROVAL <br />as noted <br />Notes: <br />4/5/2022 3:30 PM NW ELECTRICAL LLC <br />PM inspection please <br />Contact Name: Abram <br />Site Address: 4815 BAKER DR <br />Phone:2067184059 <br />e-Mail: NWELECTRICALI2@GMAIL.COM <br />(4/6/2022 12:27 PM SKB) <br />Check overcurrent AFC GFCI panel at final. <br />8/4/2022 <br />8/4/2022 <br />ELEC06-ROUGH IN <br />STEVE BANKS <br />CORRECTION <br />REQUIRED <br />Notes: <br />Consultation on job. <br />Remove or properly safe off in a box with a cover the abandonned NM cable in the crawl below floor by back door. <br />If repairs are made to the ceiling framing, a reinspection will be required for the electrical rough in after repairs are made. <br />Previous note remains to check overcurrent, AFCI and GFCI Protection at final. <br />12/21/2022 <br />12/21/2022 <br />ELEC06-ROUGH IN <br />MICHAEL <br />CORRECTION <br />WICKLANDER <br />REQUIRED <br />Notes: <br />Provide access into crawl space to verify loose nm cable correction. <br />1/25/2023 <br />1/25/2023 <br />ELEC06-ROUGH IN <br />STEVE BANKS <br />7APPROVAL <br />Notes: <br />I was out on 12-2-22 with the building inspector and saw that no electrical rough in was compromised. The contractor stated that the loose NM cable in <br />the crawlspace had been taken care of. <br />6/16/2023 <br />6/16/2023 <br />ELEC 10-FINAL <br />STEVE BANKS <br />CORRECTION <br />REQUIRED <br />Notes: <br />BRIAN 425-343-3844 <br />Provide AFCI and GFCI protection for all kitchen counter receptacles and dishwasher and disposal circuits . AFCI is required at the breaker for the new <br />home runs. Provide AFCI protection for the kitchen lighting, circuits and the microwave circuit. All receptacles below 5 feet are required to be tamper <br />resistant type. Provide physical protection for the animal Cable to the pop-up receptacle on the island. Install the light post. <br />I <br />Printed: Wednesday, 19 July, 2023 2 of 3 rk <br />SUPERION <br />