9 9 CITY OF EVERETT PARCEL 2023-12-27
>
Address Records
>
9 CITY OF EVERETT PARCEL
>
9
>
9 9 CITY OF EVERETT PARCEL 2023-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 2:51:52 PM
Creation date
12/14/2023 11:01:08 AM
Metadata
Fields
Template:
Address Document
Street Name
9 CITY OF EVERETT PARCEL
Street Number
9
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIPING SYMBOLS LINE SYMBOLS INSTRUMENT SYMBOLS LINE IDENTIFICATION SYSTEM INSTRUMENT IDENTIFICATION TABLE <br /> —M>--LINE MIXER MAIN PROCESS ULOCALLY MOUNTED INSTRUMENT/LOCAL DISPLAY GW101-2"-GALV-000 FIRST LETTER SUCCEEDING LETTERS <br /> 1HI- REMOVABLE SPOOL SECONDARY PROCESS LETTERS MEASURED OR READOUT OR OUTPUT <br /> LINE IDENTIFICATION INITIATING VARIABLE MODIFIER PASSIVE FUNCTION FUNCTION MODIFIER <br /> DIAPHRAGM SEAL EXISTING LINES CENTRAL CONTROL PANEL MOUNTED INSTRUMENT A Analysis Alarm <br /> Y LINE NUMBER B Burner,Combustion User's Choice User's Choice User's Choice <br /> C User's Choice Control <br /> "Y"TYPE STRAINER LINES TO BE DISMANTLED LINE SIZE <br /> CONE STRAINER FUTURE REAR OF PANEL MOUNTED INSTRUMENT PIPING SPECIFICATION OR D User's Choice Differential <br /> PI PING ABBREVIATION E Voltage Sensor(Primary <br /> BASKET STRAINER — — SKID OR PAKAGE LIMIT Element) <br /> CODE DESIGNATING F Flow Rate Ratio(Fraction) <br /> THIEF HATCH �( * CAPILLARY TUBE _ FUNCTIONAL PLC INSULATION <br /> G General(System) Glass, <br /> OPEN SPECTACLE BLIND 2E) LINES FROM(DRAWING NO.IN BOX) EXAMPLE: Viewing Device <br /> TWO INCH,NON-INSULATED, H Hand High <br /> CLOSED SPECTACLE BLIND LINES TO(DRAWING NO.IN BOX) e FUNCTIONAL PROCESS COMPUTER GALV GROUNDWATER LINE NO.101 <br /> I Current(Electric) Indicate <br /> UNION —P- TELEPHONE TELEMETRY SIGNAL <br /> 1 Power Scan <br /> HOSE CONNECTION ELECTRIC SIGNAL UNDEFINED INTERLOCK LOGIC K Time,Time Schedule Time Rate of Control Station <br /> I Change <br /> Y OPEN DRAIN # # # PNEUMATIC SIGNAL <br /> L Level Light Low <br /> FLANGED FITTINGS M User's Choice Momentary Middle, <br /> 1 <br /> OPEN DRAIN WITH FUNCTION/ALARM LIGHT Intermediate <br /> •j1/ <br /> LIQUID SEALSCREWED FITTINGS N User's Choice User's Choice User's Choice User's Choice <br /> CONCENTRIC REDUCER INSULATED LINE EXAMPLE: 0 User's Choice Orifice,Restriction <br /> P Pressure,Vacuum Point(Test) <br /> ECCENTRIC REDUCER INSULATED HEAT TRACED LINE Connection <br /> � FOIT FLOW TOTALIZING INDICATOR <br /> TRANSMITTER NO.101 Q Quantity Integrate,Totalize <br /> SPECIFICATION BREAK R Radiation Record <br /> LINE NUMBER CHANGE EQUIPMENT SYMBOLS S Temperature <br /> Frequency Safety Switch <br /> T Temperature Transmit <br /> O AUTOMATIC DUMP TRAP U Multivariable Multifunction Multifunction Multifunction <br /> (STEAM TRAP) <br /> �—�yI�M V Vibration,Mechanical Valve,Damper, <br /> LLL���--- <br /> FIRE HOSE REEL <br /> VALVE SYMBOLS I`1 METERING PUMP Analysis Louver <br /> W Weight,Force Well <br /> FIRE HYDRANT pQ GATE VALVE(OR MISCELLANEOUS VALVE) X Unclassified X Axis Unclassified Unclassified Unclassified <br /> 365FIRE SPRINKLER HEADS PLUG VALVE PUMP,CENTRIFUGAL Y Event,State or VAxis Relay,Compute, <br /> ^ Presence Convert <br /> VENT TO ATMOSPHERE BALL VALVE(OR MISCELLANEOUS VALVE) ELECT IC 7im,nlion Z Axis Driver,Actuator, <br /> III III III SUBMERSIBLE Unclassified <br /> GLOBE VALVE P <br /> rx VENT WITH FLAME ARRESTOR �Q UMP Final Control Element <br /> RUPTURE DISC Ike BUTTERFLY VALVE <br /> q QUICK DISCONNECT CHECKVALVE <br /> �—FLEXIBLE COUPLING DIAPHRAGM VALVE WELL PUMP ABBREVIATIONS <br /> {FLOW ELEMENT(VENTURI OR NOZZLE) NEEDLE VALVE LINE IDENTIFICATION LETTERS PIPING ABBREVIATIONS EQUIPMENT DESIGNATIONS <br /> M <br /> �I FLOW ELEMENT(ORIFICE FLANGE WITH PLATE) FOUR-WAYVALVE <br /> AL ACID ABS ACRYLONITRILE BUTADIENE STYRENE AS AIR STRIPPER <br /> FLOW ELEMENT(TURBINE METER) IBJ THREE-WAYVALVE Al INSTRUMENTAIR AC ASBESTOS CEMENT g BLOWER <br /> INLINE AT TREATED AIR <br /> v FLOW ELEMENT(PITOT TUBE) ANGLE VALVE DUCT HEATER AU UTILITY AIR CI CAST IRON C COLUMN <br /> AV AIR VENT CM CORREGATED METAL CP CONTROL PANEL <br /> FLOW STRAIGHTENING VANES M BD SLOWDOWN CPVC CHLORINATED POLYVINYL CHLORIDE <br /> DIAPHRAGM ACTUATED CONTROL VALVE BFW BOILER FEED WATER CU COPPER D DRUMS&POTS <br /> EJECTOR/EDUCTOR BLOWER,W/SILENCER BW BACKWASH WATER DH DUCT HEATER <br /> DC DOUBLE CONTAINMENT <br /> EXPANSION JOINT PRESSURE REGULATOR(SELF CONTAINED) CA CAUSTIC DI DUCTILE IRON E HEAT EXCHANGER <br /> CH STEAM CONDENSATE <br /> WELD CAP MIXER CW COOLING WATER FRP FIBERGLASS REINFORCED PLASTIC F FILTER <br /> BACK PRESSURE REGULATOR(SELF CONTAINED) CWR COOLING WATER RETURN FE FLOW ELEMENT <br /> SCD.CAP CWS COOLING WATER SUPPLY FH FIRED HEATER OR BOILER <br /> GALV GALVANIZED STEEL FQIT FLOW TOTALIZING INDICATING TRANSMITTER <br /> �I BLIND FLANGE PISTON-OPERATED VALVE DIW DEIONIZED WATER HDPE HIGH DENSITY POLYETHYLENE <br /> TANK,OPEN DR DRAIN G ELECTRIC POWER GENERATOR <br /> s DW DRINKING(POTABLE)WATER GAC GRANULAR ACIVATED CARBON <br /> SOLENOID VALVE <br /> A I PULSATION DAMPENER 4 NYL NYLON GT GASTURBINE <br /> C� <br /> N ELL 10*ELBOW PP POLYPROPYLENE <br /> hl TV BACKFLOW PREVENTOR MOTORIZED VALVE PVC POLYVINYL CHLORIDE K COMPRESSOR <br /> TANK,CLOSED FG FUEL GAS KR TIMER DELAY <br /> (NON-PRESSURE) FO FUELOIL RU RUBBER HOSE <br /> FW FRESH WATER LAH LEVEL ALARM HIGH <br /> PRESSURE RELIEF VALVE FWL FIREWATER LINE SO STEEL DUCT LI LEVEL INDICATOR <br /> SS STAINLESS STEEL LSH LEVEL SWITCH LOW <br /> CALIBRATION TUBE 0PRESSURE VESSEL GD GRAVITY DRAIN SSL STEEL <br /> VACUUM RELIEF VALVE GW GROUNDWATER M MISCELLANEOUS EQUIPMENT <br /> K CHEMICAL ADDITIVE TEF TEFLON P PUMP <br /> COMBINATION AIR/VACUUM RELIEF VALVE PRESSURE VESSEL VC VITRIFIED CLAY PI PRESSURE INDICATOR <br /> WITH PACKED BED N NITROGEN PAL PROGREALARM LOW <br /> EMERGENCVSHOWER (SPECIFY BED MATERIAL) PLC PROGRAMMABLE LOGIC COMPUTER <br /> AND EYE WASH OD DRV OIL PSL PRESSURE SWITCH HIGH <br /> os oOa SLOP GENERAL IDENTIFICATIONS T TANK(ATMOSPHERIC VESSEL) <br /> HEAT EXCHANGER <br /> R REFRIGERANT FC FAIL CLOSED V PRESSURE VESSEL <br /> FO FAIL OPEN <br /> S STEAM W WELL <br /> SA SODA ASH H-O-A HAND-OFF-AUTOMATIC <br /> M SFW SOFT WATER <br /> o SR SPENT REGEN. NC NORMALLY CLOSED <br /> EXHAUST FAN <br /> SS SANITARY SEWER NO NORMALLY OPEN PIPING INSULATION <br /> SW STORMWATER <br /> ST SAMPLE TAP 000 NO INSULATION <br /> V VENT 001 INSULATION <br /> RADIO FREQUENCY TELEMETRY <br /> VA VACUUM TR TELEMETRY RECEIVER 002 INSULATION WITH HEAT TRACING <br /> z /T� TT TELEMETRY TRANSMITTER <br /> oSIGNAL AND ANTENNA WR RECLAIMED WATER <br /> 1 LEVEL PROBE WT TREATED WATER VFD VARIABLE FREQUENCY DRIVE <br /> UUU WW WASTEWATER <br /> 3 <br /> DRAFTED BY: JEFFREY J.VALLUZZI AV 9/30/2020 PROJECT NO. <br /> BOEING EVERETT PLANT-POWDER MILL GULCH 027177120.021 <br /> DESIGNED BY: JERED A.NEWCOMB JAN 9/30/2020 LANDAU DOWNGRADIENT PLUME INTERIM ACTION-PHASE 2 <br /> ASSOCIATES EGW192 RELOCATION DATE <br /> REVIEWED P: PIPER M.ROELEN,P.E. PMR 9/30/2020 SEPTEMBER,2020 <br /> n CALL 2 WORKING DAYS <br /> PRIOR TO EXCAVATION APPROVED RY: PIPER M.ROELEN,P.E. PMR 9/30/2020 14 EVERETT,WASHINGTON SHEET <br /> G 130 2ND AVENUE S. 10 OF 14 <br /> 1-800<24-5555 <br /> DUMP NO WASTE EDMONDS,WASHINGTON 98020 PIPING AND DRAWING NO. <br /> 7 <br /> NO. DATE REVISIONS DESIGNED REVIEWED APPROVED ":90S <br /> TATus' INITIAL DATE (425)778-0907,FAX(425)778-6409 INSTRUMENTATION LEGEND �/ <br /> DRAINS TO STREAM 90%DESIGN DRAWINGS "-1 <br />